Apr 27
2013
Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611
We have CP5611, which can replace Siemens original 6 GK1 561-1AA00.
Now you can get it only need USD199.00/pc. Purchase it right now.
Here, pls read its manual. CP5611 Card introduction
As you know, Siemens original card 6 GK1 561-1AA00 has been replaced by 6 GK1 561-1AA01.
Of course, we also have a new product can replace it, it’s named CP5611-A2.
The ex-work price is USD259.00/pc, purchase it right now.
Here, pls find its manual: IN_CP5611A2_74
For any question or wholesale purchase, pls contact me:
Contact Person: Miss Nancy
Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8005
Fax: +86-0755-26898905-8008
Website: www.kollewin.com
Below is the data sheet of Siemens original 6 GK1 561-1AA01.
Product-type designation |
CP 5611 A2 |
|
COMMUNICATION PROCESSOR CP 5611 A2 PCI-CARD (32 BIT; 3.3/5V;33/ 66 MHZ) FOR CONNECTION TO PG OR PC WITH PCI-BUS TO PROFIBUS OR MPI (NO WIN9X-SUPPORT!) CURRENTLY ONLY 32BIT SUPPORT IN CONNECTION WITH SIMATIC NET V8.2 SW!
|
Transmission rate |
|
Transmission rate |
|
- at interface 1 / in accordance with PROFIBUS
|
|
|
9.6 kbit/s |
|
12 Mbit/s |
Interfaces |
|
Number of electrical connections / at interface 1 / in accordance with PROFIBUS |
1 |
Design of electrical connection / at interface 1 / in accordance with PROFIBUS |
9-pin Sub-D socket (RS 485) |
Supply voltage, current consumption, power loss |
|
Type of voltage |
DC |
Supply voltage |
|
|
5 V |
Relative symmetrical tolerance |
|
|
5 % |
Consumed current |
|
- 1 / from backplane bus / with DC / maximum
|
0.5 A |
Resistive loss |
2.5 W |
Permitted ambient conditions |
|
Ambient temperature |
|
|
5…55 °C |
|
-20…+60 °C |
|
-20…+60 °C |
Relative humidity |
|
- at 25 °C / without condensation / during operating / maximum
|
95 % |
Protection class IP |
IP00 |
Design, dimensions and weight |
|
Width |
18 mm |
Height |
102 mm |
Depth |
130 mm |
Net weight |
100 g |
Product properties, functions, components / general |
|
Number of plug-in cards in the same design / can be plugged in / per PC station |
1 |
Number of modules / note |
- |
Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum |
50 |
Software / for DP master function / required |
Yes, SOFTNET-PB DP |
Service / as DP master |
|
|
Yes |
|
Yes |
|
No |
Number of DP slaves / on DP master / usable |
64 |
Amount of data |
|
- of the address area of the inputs / as DP master / overall
|
14640 byte |
- of the address area of the outputs / as DP master / overall
|
14640 byte |
- of the address area of the inputs / per DP slave
|
244 byte |
- of the address area of the outputs / per DP slave
|
244 byte |
- of the address area of the diagnostic data / per DP slave
|
244 byte |
Service / as DP slave |
|
|
Yes |
|
No |
Amount of data |
|
- of the address area of the inputs / as DP slave / overall
|
122 byte |
- of the address area of the outputs / as DP slave / overall
|
122 byte |
Number of possible connections / for S7/PG communication / maximum |
8 |
Number of configurable connections / per PC station |
207 |
Configuration software / required |
NCM PC is included in scope of delivery of the required software product |
Product function / Port diagnostics |
Yes |
Standards, specifications, approvals |
|
Standard |
|
|
89/336/EEC |
- for safety / of CSA and UL
|
CAN/CSA C22.2 & UL 60950-1, UL 1950 |
|
EN 61000-6-3 |
- for interference immunity
|
EN 61000-6-2 |
Verification of suitability |
|
|
Yes |
|
Yes |
Accessories |
|
Accessories |
optional: MPI cable |
Recent Comments