Posts Tagged HMI adapter

Aug 15 2013

PC Adapter CN RS232 to PROFIBUS/MPI adapter

Introduction to PC Adapter CN

This adapter is compatible with Siemens PC Adapter and HMI adapter,fully support  RS232 port of PC and HMI to PROFIBUS/MPI communication, use the Siemens special protocol processing chip,it can be used for Siemens S7-300/400 series PLC and other equipments with PROFIBUS/MPI interface. RS232-RS485-power supply are all optical isolated, especially suitable for the strong interference and communication interface easily damaged industrial scene.

 PC Adapter CN

 

It is 100% compatible with Siemens original part.

 

Part#: PC Adapter CN

EX-Work Price: $286.00/pc       buy buttom

Approx. Weight: 0.3Kg
Manufacturer: Kollewin
Warranty: 1 year
Origin: China

 

User's manual PDF of PC Adapter CN:

PC Adapter CN USER MANUAL

 

It's tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products


PC Adapter CN is a high-tech adapter compatible with Siemens PC Adapter and HMI Adapter,fully support RS232 serial port of PC and HMI to PROFIBUS/MPI communication, adopt the Siemens protocol processor chip,no functional defects. PC Adapter CN is the opto-isolated adapter for industrial design.It has the surge protection and anti-lightning protection circuit on the RS232 interface and RS485 interface, support hot plug, is suitable for Siemens S7-300/400 series PLC and other equipments with PROFIBUS/MPI interface. In particular, it applies to the strong interfere industrial situations and the safeguard in the circuit guarantees the safely running of the system.
PC Adapter CN can communicate between S7-300/400PLC and RS232 interface of third party HMI,can replace the Siemens HMI Adapter.

The low version PC/MPI+ didn’t adopt the Siemens protocol processor chip,but adopt the MCU and use the software to achieve the profibus protocol,the protocol is not perfect and has the defect,only support MPI communication,not support profibus communication,can only connect few HMI and have the defect. When there are many nodes or third-party device in the network,it can’t identify every node. At the same time, it may have the risk that PC/MPI+ can’t be used after the PLC internal program is upgraded in the future.
Main Technical Specifications:

The network type and baud rate which PC Adapter CN supports:

Transmission rate

MPI

PPI

PROFIBUS

DP

Standard

Universal

9.6Kbps

-

-

19.2Kbps

-

45.45Kbps

-

-

93.75Kbps

-

-

187.5Kbps

-

500Kbps

-

-

1.5Mbps

-

 

RS232 serial port baud rate which PC Adapter CN supports:

Transmission rate

RS232-PC

RS232-HMI

 
 
9.6Kbps

(1)

 
19.2Kbps

 
38.4Kbps

 
57.6Kbps

(1)

 
115.2Kbps

(1)

 

 

Note:You only can choose 19.2Kbps and 38.4Kbps baud rate in the STEP7 software,if you need to use other baud rates,it needs the tool software.

 

The following is the comparison between PC Adapter CN and other similar products:

      Model

Function

PC Adapter CN

 

PC/MPI+

 

PC Adapter

SIEMENS

HMI Adapter

SIEMENS

SSW7

Helmholz

PPI-Bus
9.6Kbps

-

-

-

-

-

19.2Kbps

-

-

-

-

-

187.5Kbps

-

-

-

-

-

MPI-Bus
19.2Kbps

187.5Kbps

1.5Mbps

-

-

PROFIBUS
9.6 Kbps

-

-

19.2 Kbps

-

-

45.45 Kbps

-

-

93.75 Kbps

-

-

187.5 Kbps

-

-

500 Kbps

-

-

1.5 Mbps

-

-

3 Mbps

-

-

-

-

-

6 Mbps

-

-

-

-

-

12 Mbps

-

-

-

-

-

PROFIBUS-Profil
DP

-

-

Standard

-

-

Universal(DP/FMS)

-

-

RS232-PC
9.6Kbps

-

19.2Kbps

38.4Kbps

57.6Kbps

-

115.2Kbps

-

RS232-HMI
9.6Kbps

-

-

-

19.2Kbps

-

-

38.4Kbps

-

-

57.6Kbps

-

-

-

115.2Kbps

-

-

-

● RS232 interface can connect PC or HMI etc third party devices,baud rate 9.6Kbps~115.2Kbps automatically adjust.
● Support PROFIBUS and MPI communication, auto bus protocol test,largest baud rate 1.5Mbps.
● Power supply from PLC port,24VDC, Power Consumption 2W,with over current and surge protection.
● Power-RS485-RS232 all isolated
● Opto-isolated voltage 1000VDC.
● RS232 interface has the anti-surging protection
● RS485 interface has the anti-lightning and surging protector, Repeatability surge capacity: Ipp=100A(10/700us,4KV),meet the standard ITU-TK20/21、VDE 0433. ±15KV ESD protection.
● Need additional 24VDC power for the long distance communication, the largest cable length meets the profibus standard.
● With the power indicator, data sending indicator, data receiving indicator
Can install the adapter on the S7-300/400PLC rail or 35MM standard rail.
● Shape Size: 123mm×68mm×30mm(Length*Width*Height),with the mounting bracket
● Working Temperature: -20~+75℃

 

We also have other compatible PLC Programming cables of Siemens

CP5611

CP5611-A2

CP5512

CP5512EXP-NEW

PC Adapter CN-NEW

ES-ETH-PPI-NEW

ETH Adapter CN-NEW

USB/PPIM+

PC/PPI

PC/PPI+

USB/MPI+ V4.0

USB/MPI+ V2.0

PC/MPI+ including RS232 cable

PC/MPI

LOGO!USB-CABLE

LOGO!PC-CABLE

MPI extension cable

PC/TTY

 

Here, more pictures of our compatible cables of Siemens parts

ETH Adapter CN 0CB20-1 V6.0_1 PC-TTY_1 CP5512_1 CP5611-A2_1 CP5512E_1 logo-usb cable_1 logo-PC cable_1 USB-MPI+V2.0_1 USB-MPI+V4.0_1 USB-MPI V5.0_1

Of course, we also supply some other brands compatible PLC Programming cables, such as Mitsubishi/OMRON/Panasonic/GE/Fuji/Schneider/Allen-Bradley/Delta/Proface…

ES-ETH-SC09-NEW

FX-USB-AW

USB-SC09

USB-SC09-FX

SC-09+

SC-10

USB-QC30R2

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

1747-PIC

1747-UIC

1747-CP3

USB-1747-CP3 

1761-CBL-PM02

USB-1761-CBL-PM02

 

Pictures for your reference:

FX-USB-AW 1 USB-SC09-FX_1 ES-ETH-SC09 1 USB-QC30R2 1 USB-SC09_1 1747-UIC_1 1747-PIC_1 USB-1761-CBL-PM02_1 IC690ACC901_1 IC690USB901_1 TSXPCX3030_1 USB-CIF02_1 USB-CN226 _1

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com