Posts Tagged Ethernet adapter

Oct 6 2013

ES-ETH-SC09 Mitsubishi Ethernet adapter

Introduction to ES-ETH-SC09

Mitsubishi FX series PLC Ethernet adapter,is used for the communication between FX series PLC and Ethernet,Internet or 3G wireless network by the programming interface.No need to revise the communication protocol and software,support Dynamic DNS,user can remote control the PLC by the internet. The RJ45 port and RS422 interface are isolated in order to suit harsh environment in the industrial scene.

ES-ETH-SC09 is the industrial product which use the Ethernet and Internet or 3G wirelss internet to achieve Mitsubishi FX series PLC networking communication It integrates a number of complex network protocols, supports TCP Server, TCP Client, UDP unicast, UDP multicast etc many modes,.It has 10M/100M adaptive Ethernet interface and RS422 interface which meets Mitsubishi technical specifications, You only need to go on simple setting and then let the FX PLC go on Ethernet/Internet communication.

Mitsubishi FX Series PLC refers to FX0/FX0S/FX0N/FX1N/FX2N/FX3U/FX3G … …. .

ES-ETH-SC09 is an industrial grade product, its RJ45 port and RS422 interface are both isolated in order to suit harsh environment in the industrial situations. Especially each signal pin has anti-static protection and surge protection, which can effectively protect the PLC communication port from outside surges and the impact of common-mode inductance.

Notice:when the ES-ETH-SC09 is used to communicate between  the PC and the FX series PLC or between PLC and PLC, it supports the  RS422/RS485/RS232 communication which meet UART serial data communication standard. Some field buses such as PROFIBUS, PPI, MPI, CC-Link, PC-Link, etc., although the physical interface is RS485, they do not comply with the UART serial data format, so they do not apply to this product!
◆ High-speed, highly reliable industrial-grade standard, anti-interference design for harsh electromagnetic environment

◆ 32 bit RISC (NP7 series) ARM7TDMI 55DMIPS

◆ 128KB SRAM,128KB Code + 32KB Boot

◆10M/100M adaptive Ethernet interface

◆Support RS422/RS485 data bits 5,6,7,8 settable

◆Support RS422/RS485 stop bit 1,1.5,2 settable
◆Support RS422/RS485 parity NONE, ODD, EVEN, MARK, SPACE settable
◆Support RS422/RS485 baud rate 110 ~ 115200bps standard rate settable
◆Support the RS422/RS485 communications which meet UART serial data communication standard, do not support field bus protocol.
◆Smart protocols: TCP, UDP, ARP, IP, ICMP, DHCP, BOOTP, DNS

◆Support dynamic DNS
◆Working mode can be TCP Server, TCP Client, UDP multicast and unicast UDP

◆Built-in Flash memory, can save the setted parameters
◆Support Windows 95/98/ME/NT/2000/XP/2003/XP/Win7 operating system, Vista is not recommended
◆RJ45 port 1500VDC electromagnetic isolated,RS422 interface 1500VDC electromagnetic isolated,
◆Interface protection: power supply port has the reverse polarity protection and over current protection, RS422 interface has the surge protection ;all pins and terminals have anti-static protection.
◆5V±10% DC power supply from FX series PLC RS422 socket,1W power
◆Dimension: L × W × H = 65mm × 51mm × 26mm, 35mm Standard rail mounting
◆Operating Temperature: -40 ° C to +80 ° C (-40 ° F to 176 ° F), 5% to 95% RH (industrial grade)
◆Storage Temperature: -40 ° C to +80 ° C (-40 ° F to 176 ° F), 5% to 95% RH

Product Content:                                                            
1.ES-ETH-SC09  1PC  
2. RJ45 Cable 1 PC,2 M
3.CD 1PC

 

Part#: ES-ETH-SC09

Unit price:USD150.00/pc  buy buttom

S6006885 S6006883

More compatible Mitsubishi cable & communication board

ES-ETH-SC09-NEW

FX-USB-AW

USB-SC09

USB-SC09-FX

SC-09+

SC-10

USB-QC30R2

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

Pictures for your reference:

USB-SC09-FX_1 ES-ETH-SC09 1 USB-QC30R2 1 USB-SC09_1

 

Of course, we also can supply some compatible PLC Programming cables of ohter brands, such as Siemens/OMRON/Panasonic/GE/Fuji/Schneider/Allen-Bradley/Delta/Proface…

CP5611

CP5611-A2

CP5512

CP5512EXP-NEW

PC Adapter CN-NEW

ES-ETH-PPI-NEW

ETH Adapter CN-NEW

USB/PPIM+

PC/PPI

PC/PPI+

USB/MPI+ V4.0

USB/MPI+ V2.0

PC/MPI+ including RS232 cable

PC/MPI

LOGO!USB-CABLE

LOGO!PC-CABLE

MPI extension cable

PC/TTY

1747-PIC

1747-UIC

1747-CP3

USB-1747-CP3 

1761-CBL-PM02

USB-1761-CBL-PM02

 

More pictures:

USB-MPI V5.0_1 USB-MPI+V4.0_1 USB-MPI+V2.0_1 logo-PC cable_1 logo-usb cable_1 CP5512E_1 CP5611-A2_1 CP5512_1 PC-TTY_1 1747-UIC_1 0CB20-1 V6.0_1 1747-PIC_1 USB-1761-CBL-PM02_1 IC690ACC901_1 IC690USB901_1 TSXPCX3030_1 USB-CIF02_1 USB-CN226 _1

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Sep 26 2013

ETH Adapter CN Siemens S7-300/400PLC Ethernet adapter

Introduction to Siemens ETH Adapter CN

Siemens S7-300/400PLC Ethernet adapter,is used for the communication between S7-300/400PLC and Ethernet,Internet or 3G wireless network by the MPI or DP interface.No need to revise the communication protocol and software, support Dynamic DNS, user can remote control the PLC by the internet. The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial scene.

ETH Adapter CN is the industrial product which use the Ethernet and Internet or 3G wirelss network to achieve Siemens S7-300/400PLC networking communication. It integrates many complex network protocols, support TCP Server,TCP Client,UDP Unicast,UDP Multicast etc many modes.It has 10M/100M adaptive Ethernet interface and MPI and PROFIBUS interface which meets Siemens technical specifications.You only need to go on simple setting and then let the S7-300/400PLC go on network communication.

The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial situations. Especially the isolated power supply port and each signal pin has anti-static protection and surge protection which can solve the PLC communication port easily damaged problem.


◆ High-speed, reliable industry standard, anti-interference design suit for the harsh electromagnetic environment
◆ 32 bit RISC (NP7 series) ARM7TDMI 55DMIPS。
◆ 128KB SRAM,128KB Code + 32KB Boot。
◆10M/100M adaptive Ethernet interface
◆Support MPI and PROFIBUS communication protocol.
◆The largest baud rate is 1.5Mbps for MPI and Profibus interface.
◆Ethernet interface baud rate 9.6Kbps,19.2Kbps,38.4Kbps,57.6Kbps,115.2Kbps can be set.
◆Smart Protocols: TCP,UDP,ARP,IP,ICMP,DHCP,BOOTP,DNS.
◆Support Dynamic DNS
◆Working mode can be chose TCP Server,TCP Client,UDP Multicast and UDP Unicast.
◆Built-in Flash memory,can save the setted parameters
◆Support Windows 95/98/ME/NT/2000/XP/2003/XP/Vista/Win7 operation system.
◆RJ45 port 1500VDC electromagnetic isolated,RS485 interface 1000VDC electromagnetic isolated,power supply 1000VDC electromagnetic isolated
◆Interface protection: power supply port has the reverse polarity protection and over current protection,RS485 interface has the anti-lightning surge protection, repeatability surge capacity: Ipp=100A(10/700us,4KV),meet standard ITU-TK20/21、VDE 0433. ±15KV ESD protection; overcurrent protection.
◆Power supply 24V±10% DC from PLC MPI or PROFIBUS socket,2W power.
◆Shape Size: 123mm×68mm×30mm(length*width*height),with the mounting bracket.
◆Temperature: -40°C to +80°C (-40°F to 176°F),5% to 95% RH
◆Storage temperature: -40°C to +80°C (-40°F to 176°F),5% to 95% RH.

The network type and fieldbus communication baud rate which ETH Adapter CN support

Transmission rate

MPI

PPI

PROFIBUS

DP

Standard

Universal

9.6Kbps

-

-

19.2Kbps

-

45.45Kbps

-

-

93.75Kbps

-

-

187.5Kbps

-

500Kbps

-

-

1.5Mbps

-

 

Product Content                                                                              
1.ETH Adapter CN  1PC
2. RJ45 Cable 1 PC,  2 M
3.CD 1PC

 

Part#: ETH Adapter CN

Unit price:USD345.00/pc     buy buttom

ETH Adapter CN

 

Here, user's manual PDF of ETH Adapter CN:

ETH Adapter CN USER MANUAL

 

More compatible PLC Programming cables of Siemens

CP5611

CP5611-A2

CP5512

CP5512EXP-NEW

PC Adapter CN-NEW

ES-ETH-PPI-NEW

ETH Adapter CN-NEW

USB/PPIM+

PC/PPI

PC/PPI+

USB/MPI+ V4.0

USB/MPI+ V2.0

PC/MPI+ including RS232 cable

PC/MPI

LOGO!USB-CABLE

LOGO!PC-CABLE

MPI extension cable

PC/TTY

 

 

Here, more pictures of our compatible cables of Siemens parts

CP5512_1 CP5611-A2_1 CP5512E_1 logo-usb cable_1 logo-PC cable_1 PC-TTY_1

 

Of course, we also supply some other brands compatible PLC Programming cables, such as Mitsubishi/OMRON/Panasonic/GE/Fuji/Schneider/Allen-Bradley/Delta/Proface…

ES-ETH-SC09-NEW

FX-USB-AW

USB-SC09

USB-SC09-FX

SC-09+

SC-10

USB-QC30R2

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

1747-PIC

1747-UIC

1747-CP3

USB-1747-CP3 

1761-CBL-PM02

USB-1761-CBL-PM02

 

Pictures for your reference:

USB-CN226 _1 USB-CIF02_1 TSXPCX3030_1 IC690USB901_1 IC690ACC901_1 USB-1761-CBL-PM02_1 1747-PIC_1 1747-UIC_1 USB-SC09_1 USB-QC30R2 1 ES-ETH-SC09 1 USB-SC09-FX_1 FX-USB-AW 1

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com

 

Sep 25 2013

ES-ETH-PPI S7-200 PLC Ethernet adapter

Introduction to ES-ETH-PPI

Siemens S7-200PLC Ethernet adapter, is used for the communication between Siemens S7-200PLC and Ethernet, Internet or 3G wireless network by the programming interface (RS485 interface) of S7-200 PLC. No need to revise the communication protocol and software,support Dynamic DNS,user can remote control the PLC by the internet. The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial scene.

ES-ETH-PPI is the industrial product which use the Ethernet and Internet or 3G wirelss network to achieve Siemens S7-200PLC networking communication. It integrates many complex network protocols, support TCP Server,TCP Client,UDP Unicast,UDP Multicast etc many modes.It has 10M/100M adaptive Ethernet interface and 10-bit and 11-bit RS485 interface which meets Siemens technical specifications.You only need to go on simple setting and then let the S7-200PLC go on network communication.

The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial situations. Especially the isolated power supply port and each signal pin has anti-static protection and surge protection which can solve the communication port easily damaged problem for Siemens S7-200PLC.
Notice: When ES-ETH-PPI is used to communicate between PC and S7-200 PLC,you need to set the local connection as “Modem connection” in the STEP7 Micro/WIN software.When it’s used to communicate between PLC and PLC,you only can use the free port RS485 communication mode,can’t use Siemens PPI,multi-master PPI or advanced PPI protocol,also MPI and profibus protocol.

◆ High-speed, reliable industry standard, anti-interference design suit for the harsh electromagnetic environment
◆32 bit RISC (NP7 series) ARM7TDMI 55DMIPS
◆ 128KB SRAM,128KB Code + 32KB Boot
◆10M/100M adaptive Ethernet interface
◆Support Siemens technical specifications 10-bit and 11-bit RS485 communication mode
◆Support RS485 data bits 5,6,7,8 settable
◆Support RS485 stop bit 1,1.5,2 settable
◆Support RS485 Parity NONE,ODD,EVEN,MARK,SPACE settable
◆Support RS485 baud rate 110~115200bps standard baud rate settable,not support 187.5Kbps baud rate
◆Support PPI communication of RF modem and free port RS485 communication, not support advanced PPI and multi-master PPI protocol
◆Protocols: TCP,UDP,ARP,IP,ICMP,DHCP,BOOTP,DNS
◆Support Dynamic DNS
◆Working mode can be chose TCP Server、TCP Client、UDP multicast and UDP unicast.
◆Built-in Flash memory, can save the setted parameters
◆Support Windows 95/98/ME/NT/2000/XP/2003/XP/Vista/Win7
◆RJ45 port 1500VDC electromagnetic isolated, RS485 interface 1000VDC electromagnetic isolated, power supply 1000VDC electromagnetic isolated
◆Interface protection: power supply port has the reverse polarity protection and over current protection,RS485 interface has the 500W anti-lightning surge protection and overcurrent protection; all pins and terminals have anti-static protection
◆24V±10% DC power supply from PLC RS485 socket,1W power
◆Dimension: 65mm×51mm×26mm, 35mm standard rail installation
◆Temperature: -40°C to +80°C (-40°F to 176°F),5% to 95% RH

Product Content                                                                              
1. ES-ETH-PPI  1PC
2. RJ45 Cable 1 PC,2 M
3. CD 1PC

 

Part#: ES-ETH-PPI

Unit price:USD150.00/pc  buy buttom

ES-ETH-PPI-1 ES-ETH-PPI

 

Here, user's manual PDF of ES-ETH-PPI:

ES-ETH-PPI USER MANUAL

 

More compatible PLC Programming cables of Siemens

CP5611

CP5611-A2

CP5512

CP5512EXP-NEW

PC Adapter CN-NEW

ES-ETH-PPI-NEW

ETH Adapter CN-NEW

USB/PPIM+

PC/PPI

PC/PPI+

USB/MPI+ V4.0

USB/MPI+ V2.0

PC/MPI+ including RS232 cable

PC/MPI

LOGO!USB-CABLE

LOGO!PC-CABLE

MPI extension cable

PC/TTY

 

 

Here, more pictures of our compatible cables of Siemens parts

CP5512_1 CP5611-A2_1 CP5512E_1 logo-usb cable_1 logo-PC cable_1 PC-TTY_1

 

Of course, we also supply some other brands compatible PLC Programming cables, such as Mitsubishi/OMRON/Panasonic/GE/Fuji/Schneider/Allen-Bradley/Delta/Proface…

ES-ETH-SC09-NEW

FX-USB-AW

USB-SC09

USB-SC09-FX

SC-09+

SC-10

USB-QC30R2

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

1747-PIC

1747-UIC

1747-CP3

USB-1747-CP3 

1761-CBL-PM02

USB-1761-CBL-PM02

 

Pictures for your reference:

USB-CN226 _1 USB-CIF02_1 TSXPCX3030_1 IC690USB901_1 IC690ACC901_1 USB-1761-CBL-PM02_1 1747-PIC_1 1747-UIC_1 USB-SC09_1 USB-QC30R2 1 ES-ETH-SC09 1 USB-SC09-FX_1 FX-USB-AW 1

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com