May 23 2013

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM331 6ES7331-1KF01-0AB0 8AI, 13BIT

SIEMENS SIMATIC  SM7-300 ANALOG MODULE SM331  6ES7331-1KF01-0AB0  8AI, 13BIT
6ES7331-1KF01-0AB0       SM331, 8AI, 13BIT
SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, 66 MS MODULE UPDATE, 1 X 40 PIN
Here, below is the data sheet of Siemens original 6ES7331-1KF01-0AB0 :
SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, 66 MS MODULE UPDATE, 1 X 40 PIN
Input current
from backplane bus 5 V DC, max. 90 mA
Power losses
Power loss, typ. 0.4 W
Analog inputs
Number of analog inputs 8
Number of analog inputs for resistance measurement 8
permissible input voltage for voltage input (destruction limit), max. 30 V; 12 V continuous, 30 V for max. 1 s
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
Voltage Yes
Current Yes
Thermocouple No
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), voltages
0 to +10 V Yes
Input resistance (0 to 10 V) 100 kΩ
1 to 5 V Yes
Input resistance (1 to 5 V) 100 kΩ
1 to 10 V No
-1 V to +1 V Yes
Input resistance (-1 V to +1 V) 100 kΩ
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) 100 kΩ
-2.5 V to +2.5 V No
-250 mV to +250 mV No
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) 100 kΩ
-50 mV to +50 mV Yes
Input resistance (-50 mV to +50 mV) 100 kΩ
-500 mV to +500 mV Yes
Input resistance (-500 mV to +500 mV) 100 kΩ
-80 mV to +80 mV No
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 50 Ω
-10 to +10 mA No
-20 to +20 mA Yes
Input resistance (-20 to +20 mA) 50 Ω
-3.2 to +3.2 mA No
4 to 20 mA Yes
Input resistance (4 to 20 mA) 50 Ω
Input ranges (rated values), thermoelements
Type B No
Type E No
Type J No
Type K No
Type L No
Type N No
Type R No
Type S No
Type T No
Type U No
Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 Yes; Standard/climate
Input resistance (Ni 100) 100 MΩ
Ni 1000 Yes
Input resistance (Ni 1000) 100 MΩ
LG-Ni 1000 Yes; Standard/climate
Input resistance (LG-Ni 1000) 100 MΩ
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 Yes; Standard/climate
Input resistance (Pt 100) 100 MΩ
Pt 1000 No
Pt 200 No
Pt 500 No
Input ranges (rated values), resistors
0 to 150 ohms No
0 to 300 ohms No
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 100 MΩ
0 to 6000 ohms Yes
Input resistance (0 to 6000 ohms) 100 MΩ
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 200 m; max. 50 m at 50 mV
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 13 bit
Integration time, parameterizable Yes; 60 / 50 ms
Basic conversion time, ms 66 / 55 ms
Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
Encoder
Connection of signal encoders
for current measurement as 2-wire transducer Yes; with external supply
for current measurement as 4-wire transducer Yes
for resistance measurement with 2-conductor connection Yes
for resistance measurement with 3-conductor connection Yes
for resistance measurement with 4-conductor connection Yes
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to input area +/- 0,6 %; +/-0.6% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); +/-0.5% (+/-50 mV, 500 mV, 1 V)
Current, relative to input area +/- 0,5 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA
Impedance, relative to input area +/- 0,5 %; 0 to 6 kohms, 0 to 600 kohms
Resistance-type thermometer, relative to input area 1 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic); 1.2 Kelvin (Pt100, Ni100, standard)
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0,4 %; 0.4% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (+/-50 mV, 500 mV, 1 V)
Current, relative to input area +/- 0,3 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA
Impedance, relative to input area +/- 0,3 %; 0 to 6 kohms, 0 to 600 kohms
Resistance-type thermometer, relative to input area 1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic)
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Alarms
Diagnostic alarm No
Limit value alarm No
Diagnostic messages
Diagnostic functions No
Diagnostic information readable No
Diagnostics No
Group error No
Diagnostics indication LED
Group error SF (red) No
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 117 mm
Weight
Weight, approx. 250 g
Our company have the compatible cable, named 331-1KF01-0AB0,  can replace Siemens 6ES7331-1KF01-0AB0.You can have a look on the picture.

331-1KF01-0AB0

You can get it only need USD251.00/pc.    Buy now ====>  buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Please find below discription of our compatible 331-1KF01-0AB0:

Model

SM331

8AI

Product  Description

8AI;voltage/current/RTD temperature measurement modules;Resolution:13bits

Optical isolation; high immunity;stable

Power consumption
·Rate value /
·From backplane bus current consumption 90mA
·From L+ /
·Power loss 0.4W

The power of transmitter

·Supply current /
·short-circuit protection /
Number of analog inputs 8
Cable Length (Shielded) Max:200m
Input type and input range
·voltage 1~5V,0~10V,±50mV±500mV, ±1V, ±5V, ±10V
·current(4wire) ±20mA, 0~20mA, 4~20mA
·current(2wire) /
·tesistance 600Ω,6KΩ
·thermocouple /
·RTD Pt100(-200℃-850℃)
A/D resolution 13bits
Basic conversion time(per channel) 66/55ms
Interference frequency suppression 50/60Hz
Tolerance(Over entire temperature range)
·Voltage ±0.6%
·Current ±0.6%
·resistance ±0.6%
·temperature ±1℃
Interrupts
Diagnostic interrupt None
Limit-value interrupt None
Isolation tested for contact
·Between channels None
·Between channels and backplane bu Yes
Front connector 40-pin
Dimensions(W x H x D)(mm) 40×125×120
Order Number  331-1KF01-0AB0