PC/MPI+: RS232 isolated Programming adapte for Siemens S7-300/400 PLC,6ES7972-0CA23-0XA0
PC/MPI+: RS232 isolated Programming adapte for Siemens S7-300/400 PLC,6ES7972-0CA23-0XA0
SIMATIC S7, PC ADAPTER V5.1 FOR CONNECTION OF S7-300/400, C7, M7; FOR CONVERSION OF RS232 TO RS485; W/O RS232 CABLE
SIMATIC S7, PC ADAPTER V5.1 FOR CONNECTION OF S7-300/400, C7, M7; FOR CONVERSION OF RS232 TO RS485; W/O RS232 CABLE
|
|
Supply voltage | |
5 V DC | Yes; UN2 |
24 V DC | Yes; UN1 |
Input current | |
Current consumption, typ. | 90 mA; I1: 50 mA, I2: 40 mA |
Inrush current, max. | 0.5 A; I1: 0.5 A, 14 ms; I2: 0.2 A, 1.5 ms |
1st interface | |
Type of interface | RS 485 (up to max. 1.5 Mbit/s) |
2nd interface | |
Type of interface | RS 232 (19.2 kbit/s or 38.4 kbit/s, adjustable by switch) |
EMC | |
Interference immunity against discharge of static electricity | |
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes; +/-4 kV contact discharge (to IEC 801-2/IEC 1000-4-2; ESD) +/-8 kV air discharge (to IEC 801-2/IEC 1000-4-2; ESD) |
Interference immunity to cable-borne interference | |
Interference immunity on signal lines acc. to IEC 61000-4-4 | Yes; +/- 2 kV (to IEC 801-4/IEC 1000-4-4; Burst) |
Immunity against high-frequency electromagnetic fields | |
Interference immunity against high frequency radiation | 10 V/m with 80% amplitude modulation at 1 kHz, 10 kHz to 80 MHz (to ENV 50141); 10 V/m with 80% amplitude modulation at 1 kHz, 80 MHz to 1 GHz (to ENV 50140); 10 V/m pulse modulated 50% ED at 900 MHz (to ENV 50204) |
Emission of radio interference acc. to EN 55 022 | |
Interference emission acc. to EN 55022, class B | Yes; corresponds to CISPR 22 |
Degree and class of protection | |
IP20 | Yes |
Ambient conditions | |
Operating temperature | |
Min. | 0 °C |
max. | 60 °C |
Permissible temperature change | 10 °C/h; Operation: max. 10°C/h; storage/transport: max. 20°C/h |
Storage/transport temperature | |
Min. | -40 °C |
max. | 70 °C |
Relative humidity | |
Operation, min. | 5 % |
Operation, max. | 85 %; no condensation |
Storage/transport, min. | 5 % |
Storage/transport, max. | 93 %; no condensation |
Vibrations | |
Operation, checked according to IEC 60068-2-6 | Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 150 Hz: Acceleration 9.8 m/s2 |
Transport tested checked to IEC 60068-2-6 | Yes; (packed) 5 to 9 Hz, amplitude 3.5 mm; 9 to 500 Hz, acceleration 9.8 m/s2 |
Shock test | |
checked according to IEC 60068-2-27 | Yes; Operation: Half-sine: 100 m/s2 (10 g), 16 ms, transport (packed): Half-sine: 250 m/s2 (25 g), 6 ms |
checked according to IEC 60068-2-29 | Yes |
Dimensions | |
Width | 50 mm |
Height | 24 mm |
Depth | 108 mm |
Weight | |
Weight, approx. | 150 g |
Our company have the compatible cable, named PC/MPI+,including RS232 cable, can replace Siemens original 6ES7972-0CA23-0XA0.
Please look at below picture of our compatible PC/MPI+ including RS232 cable :
You can get it only need USD90.00/pc. Buy now ====>
When you buy PC/MPI+,we will give you the free RS232 Cable.
It’s tested before shippment.Not made by Siemens,OEM product as the replacement.
The quality is guaranteed, we have 1 year warranty for our compatible products.
Description of our compatible PC/MP+ :
Optoelectronic isolated RS232/MPI,Siemens S7-300/400 PLC Programming adapter cable,with communication indicator,can replace Siemens 6ES7 972-0CA23-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.Can connect PLC and the touch panel of third party factory to communicate.It doesn’t support profibus function.
PC/MPI+ adapter, or named PC adapter, could achieve the level conversion of RS232 to RS485 and the protocal conversion of RS232 to MPI(MultiPoint Interface).PC/MPI+ is the adapter of photoelectric isolation type towards industrial design. Between RS232 port and RS485 port exist the surge protection and anti-lightning protection circuit, adaptable to the full PLC series of Siemens S7-300/400 and those devices with MPI port, especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give promission to the safe operation of the system.
PC/MPI+ can make touch-screen communications with the third party under the link of S7-300/400PLC, such as eView, Wei-lun and kun-lun state.
Characteristics and main technical parametres:
★ Power: It is supplied by the 24VDC MPI port of PLC, power consumption of about 1w, with overcurrent protection and surge protection.
★ Isolation Voltage: 1000VDC(Maximun to 3000 VDC, orders require statement.)
★ RS232 port has anti-surge protection, RS485 port has anti-lightning protection and overcurrent protection with the consumption of 500w.
★ RS232 port baud rate: 19.2Kbps—115.2Kbps, automatically adaptable to the standard baud rate.
★ MPI port baud rate: 187.5Kbps—19.2Kbps, automatically adaptable.
★ Supporting the connection of PLC to touch-screen communication with the third party.
★ With a power indicater light, on-line and data transmission indicater light.
★ Working temperature: -20~75′C
★ Dimension: 103×50×26; After connecting the RS232 cables: 5.5m.
RS232 adapter port and port-pin RS485 signal definations:
Pin number |
Signal name |
Instructions |
Pin number |
Signal name |
Instructions |
|
1 |
DCD |
No use |
1 |
NC |
No use | |
2 |
RXD |
RS232 signal reception |
2 |
M24V |
Negtive 24VDC power | |
3 |
TXD |
RS232 signal sending |
3 |
B |
RS485 positive signal | |
4 |
DTR |
Short circuit with No.6 |
4 |
RTSAS |
Data reception control | |
5 |
GND |
RS232 signal to ground |
5 |
GND |
RS485 signal to ground | |
6 |
DSR |
Short cut with No.4 |
6 |
NC |
No use | |
7 |
RTS |
Sending requsts |
7 |
P24V |
24VDC positive power | |
8 |
CTS |
Sending clear |
8 |
A |
RS485 negtive signal | |
9 |
RI |
No use |
9 |
RTS_PG |
Data-send control |
RS232-Block(DB9M) defination signals RS485-Block(DB9M) defination signals
Indicater light |
On |
Qlittering |
Out |
Power |
Normal |
Error |
Error or failing to link to power |
Active |
Online |
Transmission of data |
Not online |
Tx |
Error |
Send data |
No data transmission |
Instructions of the indicater light
Software settings of STEP7:
Entering the main interface of STEP7 programming software(SIMATIC Manager), clicking on “Options” menu under the “Set PG/PC Interface…” option into the PG/PC interface settings.
1. Double clicking on “PC Adapter(MPI)” into the RS232 interfaces and MPI set of parameters. The adapter does not support “PC Adapter(PROFIBUS)” option.
2. Clicking on “Local Connection” option set RS232 interface parameters, choosing PC/MPI to connect on the port of COM correctly, and it will adapt to the chosen baud rate automatically, both 19200bps and 38400bps of RS232 communication.
3. Clicking “MPI” to set port parameters of adapter MPI, acceptable at both 187.5Kbps and 19.2Kbps, and the adapter will adapt to its baud rate automatically. Others have already been set.
4. On-line test accessing point: Using PC/MPI to connect to MPI port and RS232 port of the computer. And then click on the button in the red circle as follow, if appearing the data inside the red line, the test has passed. Then one could operate on it.
The long-distance communication of PC/MPI+ adapter:
1. To extend the distance of RS485 port:
2. To extend the distance of RS232 port:
RS232 Cable:
When you buy PC/MPI+,we will give you the free RS232 Cable.
The quality is guaranteed.It’s tested before shippment.Not made by Siemens,OEM product as the replacement.
Recent Comments