Jul 25 2013

Siemens 6ES7 392-1AJ00-0AA0 front connector

Siemens 20 pin front connector 6ES7 392-1AJ00-0AA0 

Title German Frontstecker: 6ES7392-1AJ00-0AA0
Title English Front connector: 6ES7 392-1AJ00-0AA0
Type of object (content) Product graphic (perspective)
Search term(s) SIMATIC S7-300, S7-300, CAD
Search items/synonyms
German
front connector, 20-pin, screw-type terminal
Search items/synonyms
English
Frontstecker, 20-polig, Schraubkontakte
Product family SIMATIC Controller
Order number (e.g. 1AB1234-1AB12) 6ES7392-1AJ00-0AA0
 
 
Description to Siemens 6ES7 392-1AJ00-0AA0
 
SIMATIC S7-300, FRONT CONNECTOR FOR SIGNAL MODULES WITH SCREW CONTACTS, 20-PIN
 

Technical data of Siemens 6ES7 392-1AJ00-0AA0:

                             14

SIMATIC S7-300, FRONT CONNECTOR FOR SIGNAL MODULES WITH SCREW CONTACTS, 20-PIN
 
Accessories
belongs to product S7-300
Weight
Weight, approx. 70 g

 

Our company (Kollewin Technology CO., Limited) have a new product, named 6ES7 392-1AJ00-0AA0.

It is 100% compatible with Siemens original part. 

Part#: 6ES7 392-1AJ00-0AA0
Description: FRONT CONNECTOR
Manufacturer: Kollewin
FRONT CONNECTOR:  20-PIN, WITH SCREW-TYPE CONTACTS
Approx. Weight: 0.07 Kg
Warranty: 1 year
Origin: China

The EX-work price is USD10.50   buy buttom
100pcs or more $8.40
200pcs or more $7.40
500pcs or more $6.40

 

Pictures of our front connector 6ES7 392-1AJ00-0AA0 (20-PIN)

6ES7 392-1AJ00-0AA0_1

 

PDF of 20-PIN Simens front connector 6ES7392-1AJ00-0AA0:

Siemens 20-PIN data sheet 6ES7 392-1AJ00-0AA0

 

 

40-pin & 48-pin front connector with screw-type contacts

40-PIN    6ES7 392-1AM00-0AA0

 

48-PIN   6ES7 492-1AL00-0AA0

 
More compatible Siemens accessories 
Model Short Description
6ES7 972-0BA12-0XA0 Profibus connector,without PG port,90 degree
6ES7 972-0BB12-0XA0 Profibus connector,with PG port,90 degree
6ES7 972-0BA41-0XA0 Profibus Connector,without PG port,35 degree
6ES7 972-0BB41-0XA0 Profibus Connector,with PG port,35 degree
6ES7 972-0BA42-0XA0 Profibus Connector,without PG port,35 degree
6ES7 972-0BB42-0XA0 Profibus Connector,with PG port,35 degree
6ES7 972-0BA50-0XA0 DP ,90 DEGREE ,NO PROGRAMMING INTER,FAST CONNECT
6ES7 972-0BB50-0XA0 DP ,90 DEGREE ,WITH PROGRAMMING INTER,FAST CONNECT
6ES7 972-0BA52-0XA0  
6ES7 972-0BB52-0XA0  
6GK1500-0FC00  
6GK1500-0FC10  
6GK1500-0EA02  
6ES7 291-8GF23 Plus memory card (capacity of 64K)
6ES7 290-6AA20  
6ES7 307-1EA01-0AA0 power supply,5A,24VDC output,120/230VAC input
6ES7 307-1KA02-0AA0 SIMATIC S7-300


STABILIZED POWER SUPPLY PS307


INPUT: 120/230 V AC


OUTPUT: DC 24 V DC/10 A
6ES7 390-1AF30-0AA0 S7-300 PLC rail,530 MM length.
6ES7 390-1AJ30-0AA0 S7-300 PLC rail,830 MM length.
6ES7 390-1AB60-0AA0 S7-300 PLC rail,160 MM length.
6ES7 390-1AE80-0AA0 S7-300 PLC rail,482 MM length.
6ES7 390-1BC00-0AA0 S7-300 PLC rail,2000 MM length.
6ES7195-1GA00-0XA0 hot plug rail,483mm
6ES7195-1GF30-0XA0 hot plug rail,530mm
6ES7195-1GG30-0XA0 hot plug rail,620mm
6ES7195-1GC00-0XA0 hot plug rail,2000mm
6XV1-830-0EH10 Profibus cable
6XV1840-2AH10 profibus cable
6XV1830-3EH10 profibus cable
 
 
Not made by Siemens,but the quality is 100% guaranteed,1 year warranty.

All of our compatible products are tested one by one by our Engineer department before shipment.

 

More compatible Siemens accessories we can offer:

6ES7 392-1AM00-0AA0_2 6ES7 492-1AL00-0AA0_1   6ES7 972-0BB12-0XA0 6ES7 390-1AE80-0AA0-1 6ES7 307-1KA01-0AA0_1 6XV1830-0EH10_1 6GK1500-0FC10_1 6GK1500-0FC00_1 6ES7 972-0BB52-0XA0_1 6ES7 972-0BA52-0XA0_1 6ES7 972-0BB42-0XA0_1 6ES7 972-0BA42-0XA0_1 6ES7 972-0BB41-0XA0_1 6ES7 972-0BA41-0XA0_1 6GK1500-0EA02-1 6ES7 972-0BA12-0XA0
 
 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com

 

 
Jul 24 2013

Mitsubishi FX3U-CNV-BD FX3U Communication Board

Introduction to Mitsubishi FX3U-CNV-BD

 

The special adaptor connection board FX3U-CNV-BD is an expansion board for connecting the analog and communication special adaptors to the main unit of a PLC.

17

 

1.1 Incorporated Items of Mitsubishi FX3U-CNV-BD

18

 

1.2 External Dimensions and Part Names of Mitsubishi FX3U-CNV-BD

19

 

Installation of Mitsubishi FX3U-CNV-BD

• Cut off all phases of the power source externally before starting the installation or wiring work, thus avoiding electric shock or damages to the product.

• Use the product in the environment within the general specifications described in PLC main unit manual (Hardware Edition).
Never use the product in areas with dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl2, H2S, NH3, SO2, or NO2), flammable gas, vibrations or impacts, or expose it to high temperature, condensation, or wind and rain.If the product is used in such a place described above, electrical shock, fire,malfunction, damage, or deterioration may be caused.
• Use screwdrivers carefully when performing installation work, thus avoiding accident or product damage.
• When drilling screw holes or wiring, cutting chips or wire chips should not enter ventilation slits.Such an accident may cause fire, failure or malfunction.
• Do not touch the conductive parts of the product directly, thus avoiding failure or malfunction.
• Fix the expansion board securely to the specified connector. Incorrect connection may cause malfunction.

The following explains the installation method to FX3U/FX3UC Series PLC (FX3U Series PLC is used for the following example).
For removing and installing details, refer to the PLC main unit manual.
However, FX3UC Series PLC manual is only available in Japanese.

 

2.1 Installation Method of Mitsubishi FX3U-CNV-BD

5

• Refer to the procedure 2) for configuring a new system.
• Refer to the procedure 1) for adding product to an existing system.
1) Power off the PLC.
Disconnect all the cables connected to the PLC.
Dismount the PLC from the DIN rail.
2) Using a flat blade screwdriver as shown in the right figure, lift the little dummy expansion board cover (right fig. A). Do not damage the circuit board or electronic parts.
3) Remove the dummy expansion board cover (right fig. A) in a parallel motion away from the main unit.
4) Make sure the expansion board (right fig. B) is in parallel with the main unit (right fig. C) and fix it to the expansion board connector.
5) Fix the expansion board (right fig. B) to the main unit using the M3 tapping screws of the provided (right fig. D).
Tighten to a torque: 0.3 to 0.6 N⋅m

 

Specification of Mitsubishi FX3U-CNV-BD

STARTUP AND MAINTENANCE PRECAUTIONS of Mitsubishi FX3U-CNV-BD

• Do not disassemble or modify the unit.
  Doing so may cause failure, malfunction or fire.
  * For repair, contact your local Mitsubishi Electric distributor.
• Do not drop the product or do not exert strong impact, doing so may cause damage.

DISPOSAL PRECAUTIONS of Mitsubishi FX3U-CNV-BD

• Please contact a company certified in the disposal of electronic waste for environmentally safe recycling and disposal of the product.

TRANSPORT AND STORAGE PRECAUTIONS of Mitsubishi FX3U-CNV-BD

• During transportation avoid any impact as the product is a precision instrument.
  Check the operation of the product after transportation.

 

3.1 Applicable PLC of Mitsubishi FX3U-CNV-BD

Model name Applicability
FX3U Series PLC Ver.2.00 or later (from the first product)
FX3UC Series PLC  Ver.1.00 or later

Only one function expansion board can be used for one main unit.
Two or more FX3U-CNV-BD cannot be used, or other expansion boards such as FX3U-422-BD or FX3U-485-BD cannot be installed/used together with FX3U-CNV-BD.

 

3.2 General Specifications of Mitsubishi FX3U-CNV-BD
General specifications are the same as the PLC main unit.

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX3U-CNV-BD.

It is 100% compatible with Mitsubishi original FX3U-CNV-BD.

 

Part#: FX3U-CNV-BD

The unit price is USD29.90/pc   buy buttom

 

USER'S MUNUAL PDF of communication board FX3U-CNV-BD:

Expansion board FX3U-CNV-BD

FX3U-CNV-BD

 

Description of communication board FX3U-CNV-BD:

  • The special adaptor connection board FX3U-CNV-BD is an expansion board for
    connecting the analog and communication special adaptors to the main unit of a PLC.
  • This is OEM product, not Mitsubishi original part.

 

More communication boards we have

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of communication board

FX1N-232-BD FX1N-232-BD -1 FX2N-485-BD FX1N-USB-BD-1 FX3U-USB-BD FX3U-485-BD FX3U-422-BD FX3U-232-BD FX2N-485-BD+ FX2N-485-BD FX2N-232-BD FX1N-485-BD FX1N-422-BD FX2N-USB-BD-1 FX2N-422-BD

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 23 2013

Mitsubishi FX3U-USB-BD FX3U Communication Board

Introduction to Mitsubishi FX3U-USB-BD

 

The FX3U-USB-BD board (hereinafter called USB-BD) is a function extension board for USB communication equipped with an USB port (MINI B plug, female).By connecting the USB-BD and a personal computer, program transfer to a PLC main unit and monitoring can be performed.

 

1.1 Incorporated Items of Mitsubishi FX3U-USB-BD
Check if the following product and items are included in the package:

Product  USB communication expansion board FX3U-USB-BD 1
Included
items
M3 tapping screws
USB driver software (CD-ROM)
USB cable (3m (118.1"))
User's Manual (this manual)
2
1
1
1

 

1.2 External Dimensions and Part Names of Mitsubishi FX3U-USB-BD

8

 

Installation of Mitsubishi FX3U-USB-BD

• Cut off all phases of the power source externally before starting the installation or wiring work, thus avoiding electric shock or damages to the product.

• Use the product in the environment within the general specifications described in PLC main unit manual (Hardware Edition).
Never use the product in areas with dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl2, H2S, NH3, SO2, or NO2), flammable gas, vibrations or impacts, or expose it to high temperature, condensation, or wind and rain.If the product is used in such a place described above, electrical shock, fire,malfunction, damage, or deterioration may be caused.
• Use screwdrivers carefully when performing installation work, thus avoiding accident or product damage.
• When drilling screw holes or wiring, cutting chips or wire chips should not enter ventilation slits.Such an accident may cause fire, failure or malfunction.
• Do not touch the conductive parts of the product directly, thus avoiding failure or malfunction.
• Fix the expansion board securely to the specified connector. Incorrect connection may cause malfunction.

The following explains the installation method to FX3U/FX3UC Series PLC (FX3U Series PLC is used for the following example).
For removing and installing details, refer to the PLC main unit manual.
However, FX3UC Series PLC manual is only available in Japanese.

 

2.1 Installation Method of Mitsubishi FX3U-USB-BD

5

• Refer to the procedure 2) for configuring a new system.
• Refer to the procedure 1) for adding product to an existing system.
1) Power off the PLC.
Disconnect all the cables connected to the PLC.
Dismount the PLC from the DIN rail.
2) Using a flat blade screwdriver as shown in the right figure, lift the little dummy expansion board cover (right fig. A). Do not damage the circuit board or electronic parts.
3) Remove the dummy expansion board cover (right fig. A) in a parallel motion away from the main unit.
4) Make sure the expansion board (right fig. B) is in parallel with the main unit (right fig. C) and fix it to the expansion board connector.
5) Fix the expansion board (right fig. B) to the main unit using the M3 tapping screws of the provided (right fig. D).
Tighten to a torque: 0.3 to 0.6 N⋅m

 

Specification of Mitsubishi FX3U-USB-BD

3.1 Applicable PLC of Mitsubishi FX3U-USB-BD

Model name Applicability
FX3U Series PLC Ver.2.00 or later (from the first product)
FX3UC Series PLC  Ver.1.00 or later

Only one function expansion board can be used for one main unit.
Two or more FX3U-USB-BD cannot be used, or other expansion boards such as FX3U-422-BD or FX3U-485-BD cannot be installed/used together with FX3U-USB-BD. 

 

3.2 General Specifications of Mitsubishi FX3U-USB-BD
General specifications are equivalent to the PLC main unit.
However, please don't perform any dielectric withstand voltage test and insulation resistance test to this product.

 

3.3 Power Supply Specification of Mitsubishi FX3U-USB-BD

Item  Specification
Current consumption 15mA / DC 5V (supplied by DC 5V power of main unit)
30mA / DC 5V (supplied by USB connector of personal
computer)

 

3.4 Communication Specifications of Mitsubishi FX3U-USB-BD

Item  Specification
Transmission
standard
USB2.0 (For full speed)
Isolation Photocoupler isolation
(Between communication line and CPU)
Maximum
transmission distance
5m (196.9") at most (Included cable is 3m(118.1").)
Baud Rate 9600/19200/38400/57600/115200 bps
Port USB (MINI B plug female)

 

3.5 System Requirements of Mitsubishi FX3U-USB-BD

10

 

System Configuration of Mitsubishi FX3U-USB-BD
Connected equipment and connected cable

11

 

Connecting Procedure of Mitsubishi FX3U-USB-BD
1) Power off the PLC.
2) Connect the USB (MINI B plug male) connector of the USB cable to the FX3U-USB-BD.
3) Connect the USB (A plug male) connector of the USB cable to the personal computer.
4) Turn ON the power supply of the PLC.
5) Turn ON the power supply of the personal computer.
6. Driver Installation
Procedure for installing the driver is explained below.
Windows XP installation follows.
• Windows 98, Windows 98SE, Windows Millennium Edition, and Windows2000, the installation method will vary.
Installation of the driver is canceled during the following process, the installation is not carried out correctly.
If the installation is canceled, uninstall the driver and install again.
Please refer to Chapter 8 for instructions on uninstalling the driver.
Please install the driver with the following procedure.
1)When the USB cable is connected to the personal computer, the following screen is displayed.When the USB cable is connected to the personal computer, the following screen is displayed.

12

2) The following screen is displayed. (Only in Windows XP)

13

3) The following screen is displayed.

14

Click [ Finish ].
The installation of the USB driver software will finish.
- If Windows 98, Windows 98SE or Windows Millennium Edition is used,installation of the USB Serial Port software begins, and ends automatically.
The CD-ROM can be removed from the personal computer at this time.
- If using Windows 2000 or Windows XP, proceed to step 4).

4) The following screen is displayed.

15

Click [ Next > ].
The installation of the USB Serial Port software will begin.
- If using Windows 2000, a screen to select the location of the installation files is displayed.
Please select the CD-ROM drive.
5) The screen of 2) is displayed. (Only in Windows XP)
Click [ Continue Anyway ].

6) The following screen is displayed.

16

Click [ Finish ].
The installation of the USB Serial Port software will finish.
The CD-ROM (USB driver software) can be removed from the personal computer at this time.

 

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX3U-USB-BD.

It is 100% compatible with Mitsubishi original FX3U-USB-BD.

 

Part#: FX3U-USB-BD

The unit price is USD40.69/pc   buy buttom

 

USER'S MUNUAL PDF of communication board FX3U-USB-BD:

USB COMMUNICATION BOARD FX3U-USB-BD

 

FX3U-USB-BD

 

Specification of communication board FX3U-USB-BD:

Product Name Communication Board
Fit for Mitsubishi FX3U PLC
Model NO. FX3U-USB-BD
Transmission standard USB2.0 (For full speed)
Voltage DC 5V
Current consumption 15mA / DC 5V (supplied by DC 5V power of main unit)
30mA / DC 5V (supplied by USB connector of personal
computer)
Max.Transmission Distance 5m (196.9") at most (Included cable is 3m(118.1").)
LED Indicators SD, RD
Communication Method Half-duplex
Isolation Photocoupler isolation
(Between communication line and CPU)
Material Plastic, Metal
Net Weight 20g
Port USB Connector(MINI B plug female)
Package Content 2 x M3 tapping screws
1 x USB driver software (CD-ROM)
1 x USB cable (3m (118.1"))
1 x User's Manual (this manual)

 

Description of communication board FX3U-USB-BD:

  • This is a USB communication expansion board FX3U-USB-BD. FX3U-USB-BD is an expansion board equipped with an European temial black for USB communication.
  • The FX3U-USB-BD exchange data with USB devices.
  • FX3U-USB-BD:USB Board for FX3U PLC, anti-static electricity and surging protection.
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of communication board 

FX1N-232-BD FX1N-232-BD -1 FX2N-485-BD FX1N-USB-BD-1 FX3U-CNV-BD FX3U-485-BD FX3U-422-BD FX3U-232-BD FX2N-485-BD+ FX2N-485-BD FX2N-232-BD FX1N-485-BD FX1N-422-BD FX2N-USB-BD-1 FX2N-422-BD

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 22 2013

Mitsubishi FX3U-485-BD RS485 Board

Introduction to Mitsubishi FX3U-485-BD

FX3U-485-BD is a expansion board equipped with an European terminal block for RS-485 communication. FX3U-485-BD exchanges data RS-485 devices.

1.1 Incorporated Items of Mitsubishi FX3U-485-BD

Product  RS-485 communication expansion board FX3U-485-BD
Included
items
M3 tapping screws for installation: 2 pcs.
Station number labels for linking
Installation Manual (This manual)

 

1.2 Communication Function of Mitsubishi FX3U-485-BD

Communication type  Function
N:N network  Data transfer connecting up to eight FX Series PLCs.
Parallel link Data transfer between two PLCs relationship specifying
master/slave station.
Computer link Data transfer via dedicated protocol between PLC and
computer (specified as the master station).
Non-protocol
communication
Serial communication via non-protocol between PLC and
RS-485 device.
Inverter communication Controlling Mitsubishi's FREQROL inverter using Inverter
communication instructions.

 

1.3 External Dimensions and Part Names of Mitsubishi FX3U-485-BD

7

 

Installation of Mitsubishi FX3U-485-BD

INSTALLATION PRECAUTIONS of Mitsubishi FX3U-485-BD

• Cut off all phases of the power source externally before starting the installation or wiring work, thus avoiding electric shock or damages to the product.

• Use the product in the environment within the general specifications described in PLC main unit manual (Hardware Edition).
Never use the product in areas with dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl2, H2S, NH3, SO2, or NO2), flammable gas, vibrations or impacts, or expose it to high temperature, condensation, or wind and rain.If the product is used in such a place described above, electrical shock, fire,malfunction, damage, or deterioration may be caused.
• Use screwdrivers carefully when performing installation work, thus avoiding accident or product damage.
• When drilling screw holes or wiring, cutting chips or wire chips should not enter ventilation slits.Such an accident may cause fire, failure or malfunction.
• Do not touch the conductive parts of the product directly, thus avoiding failure or malfunction.
• Fix the expansion board securely to the specified connector. Incorrect connection may cause malfunction.

 

The following explains the installation method to FX3U/FX3UC Series PLC (FX3U Series PLC is used for the following example).
For removing and installing details, refer to the PLC main unit manual. However, FX3UC Series PLC manual is only available in Japanese.

 

2.1 Installation Method of Mitsubishi FX3U-485-BD

5

• Refer to the procedure 2) for configuring a new system.
• Refer to the procedure 1) for adding product to an existing system.
1) Power off the PLC.
Disconnect all the cables connected to the PLC.
Dismount the PLC from the DIN rail.
2) Using a flat blade screwdriver as shown in the right figure, lift the little dummy expansion board cover (right fig. A). Do not damage the circuit board or electronic parts.
3) Remove the dummy expansion board cover (right fig. A) in a parallel motion away from the main unit.
4) Make sure the expansion board (right fig. B) is in parallel with the main unit (right fig. C) and fix it to the expansion board connector.
5) Fix the expansion board (right fig. B) to the main unit using the M3 tapping screws of the provided (right fig. D).
Tighten to a torque: 0.3 to 0.6 N⋅m

 

Specification of Mitsubishi FX3U-485-BD

STARTUP AND MAINTENANCE PRECAUTIONS of Mitsubishi FX3U-485-BD

• Do not disassemble or modify the unit.
  Doing so may cause failure, malfunction or fire.
  * For repair, contact your local Mitsubishi Electric distributor.
• Do not drop the product or do not exert strong impact, doing so may cause damage.

DISPOSAL PRECAUTIONS of Mitsubishi FX3U-485-BD

• Please contact a company certified in the disposal of electronic waste for environmentally safe recycling and disposal of the product.

TRANSPORT AND STORAGE PRECAUTIONS of Mitsubishi FX3U-485-BD

• During transportation avoid any impact as the product is a precision instrument.
  Check the operation of the product after transportation.

 

3.1 Applicable PLC of Mitsubishi FX3U-485-BD

Model name Applicability
FX3U Series PLC Ver.2.00 or later (from the first product)
FX3UC Series PLC  Ver.1.00 or later

Only one function expansion board can be used for one main unit.
Two or more FX3U-485-BD cannot be used, or other expansion boards such as FX3U-422-BD or FX3U-232-BD cannot be installed/used together with FX3U-485-BD.

 

3.2 General Specifications of Mitsubishi FX3U-485-BD
General specifications are equivalent to the PLC main unit. For general specifications, refer to the following manual.
However, since the product is not isolated between communication lines and the CPU of main unit, please don't perform any dielectric withstand voltage test and insulation resistance test to this product.

 

3.3 Power supply specifications of Mitsubishi FX3U-485-BD
5V DC, 40 mA is supplied as the power from the main unit.

 

3.4 Communication specifications of Mitsubishi FX3U-485-BD

Item Specification
Transmission
standard
In conformance to RS-485/RS-422
Maximum
transmission distance
50 m (164ft) maximum
Connection method 8-pin MINI DIN (female)
Communication
method
Half-duplex
Communication
format
Non-protocol communication, computer link (dedicated
protocol format 1 and 4), parallel link, and N:N network
Baud rate No protocol, Computer link
: 300/600/1200/2400/4800/9600/19200 bps
Parallel link : 115200bps
N:N network : 384000 bps
Insulation Not insulated (Between communication line and CPU)

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX3U-485-BD.

It is 100% compatible with Mitsubishi original FX3U-485-BD.

 

Part#: FX3U-485-BD

The unit price is USD29.90/pc   buy buttom

 

USER'S MUNUAL PDF of communication board FX3U-485-BD:

RS-485 COMMUNICATION BOARD FX3U-485-BD

FX3U-485-BD

 

Specification of communication board FX3U-485-BD:

Product Name Communication Board
Fit for Mitsubishi FX3U PLC
Model NO. FX3U-485-BD
External Connector Type In Conformance to RS-485
Voltage DC 5V
Current 40mA
Max.Transmission Distance 15M
LED Indicators SD, RD
Communication Method Half-duplex
Insulation No Insulated
Material Plastic, Metal
Net Weight 15g
Package Content

1 x Communication Board

2 x Install Screw

 

Description of communication board FX3U-485-BD:

  • This is a RS-485 communication expansion board FX3U-485-BD. FX3U-485-BD is an expansion board equipped with an European temial black for RS-485 communication.
  • The FX3u-485-BD exchange data with RS-485 devices.
  • FX3U-485-BD:RS485 Board for FX3U PLC, anti-static electricity and surging protection.
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of communication board

FX1N-232-BD FX1N-232-BD -1 FX2N-485-BD FX1N-USB-BD-1 FX3U-USB-BD FX3U-CNV-BD FX3U-422-BD FX3U-232-BD FX2N-485-BD+ FX2N-485-BD FX2N-232-BD FX1N-485-BD FX1N-422-BD FX2N-USB-BD-1 FX2N-422-BD

 

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 21 2013

Mitsubishi FX3U-422-BD RS422 Board

Introduction to Mitsubishi FX3U-422-BD

FX3U-422-BD is the board with a port for connecting a programming tool, GOT, or ET
Series.


1.1 Incorporated Items of Mitsubishi FX3U-422-BD

Product  RS-422 communication expansion board FX3U-422-BD
Included
items
M3 tapping screws for installation: 2 pcs.
Installation Manual (This manual)

 

1.2 External Dimensions and Part Names of Mitsubishi FX3U-422-BD

6 

 

 

Installation of Mitsubishi FX3U-422-BD

INSTALLATION PRECAUTIONS of Mitsubishi FX3U-422-BD

• Cut off all phases of the power source externally before starting the installation or wiring work, thus avoiding electric shock or damages to the product.

• Use the product in the environment within the general specifications described in PLC main unit manual (Hardware Edition).
Never use the product in areas with dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl2, H2S, NH3, SO2, or NO2), flammable gas, vibrations or impacts, or expose it to high temperature, condensation, or wind and rain.If the product is used in such a place described above, electrical shock, fire,malfunction, damage, or deterioration may be caused.
• Use screwdrivers carefully when performing installation work, thus avoiding accident or product damage.
• When drilling screw holes or wiring, cutting chips or wire chips should not enter ventilation slits.Such an accident may cause fire, failure or malfunction.
• Do not touch the conductive parts of the product directly, thus avoiding failure or malfunction.
• Fix the expansion board securely to the specified connector. Incorrect connection may cause malfunction.

 

The following explains the installation method to FX3U/FX3UC Series PLC (FX3U Series PLC is used for the following example).
For removing and installing details, refer to the PLC main unit manual. However, FX3UC Series PLC manual is only available in Japanese.

 

2.1 Installation Method of Mitsubishi FX3U-422-BD

5

• Refer to the procedure 2) for configuring a new system.
• Refer to the procedure 1) for adding product to an existing system.
1) Power off the PLC.
Disconnect all the cables connected to the PLC.
Dismount the PLC from the DIN rail.
2) Using a flat blade screwdriver as shown in the right figure, lift the little dummy expansion board cover (right fig. A). Do not damage the circuit board or electronic parts.
3) Remove the dummy expansion board cover (right fig. A) in a parallel motion away from the main unit.
4) Make sure the expansion board (right fig. B) is in parallel with the main unit (right fig. C) and fix it to the expansion board connector.
5) Fix the expansion board (right fig. B) to the main unit using the M3 tapping screws of the provided (right fig. D).
Tighten to a torque: 0.3 to 0.6 N⋅m

 

Specification of Mitsubishi FX3U-422-BD

STARTUP AND MAINTENANCE PRECAUTIONS of Mitsubishi FX3U-422-BD

• Do not disassemble or modify the unit.
  Doing so may cause failure, malfunction or fire.
  * For repair, contact your local Mitsubishi Electric distributor.
• Do not drop the product or do not exert strong impact, doing so may cause damage.

 

DISPOSAL PRECAUTIONS of Mitsubishi FX3U-422-BD

• Please contact a company certified in the disposal of electronic waste for environmentally safe recycling and disposal of the product.

 

TRANSPORT AND STORAGE PRECAUTIONS of Mitsubishi FX3U-422-BD

• During transportation avoid any impact as the product is a precision instrument.
  Check the operation of the product after transportation.

 

3.1 Applicable PLC of Mitsubishi FX3U-422-BD

Model name Applicability
FX3U Series PLC Ver.2.00 or later (from the first product)
FX3UC Series PLC  Ver.1.00 or later

Only one function expansion board can be used for one main unit.
Two or more FX3U-422-BD cannot be used, or other expansion boards such as FX3U-232-BD or FX3U-485-BD cannot be installed/used together with FX3U-422-BD.

 

3.2 General Specifications of Mitsubishi FX3U-422-BD
General specifications are equivalent to the PLC main unit. For general specifications, refer to the following manual.
However, since the product is not isolated between communication lines and the CPU of main unit, please don't perform any dielectric withstand voltage test and insulation resistance test to this product. 

 

3.3 Power supply specifications of Mitsubishi FX3U-422-BD
5V DC, 20 mA is supplied as the power from the main unit. However, current consumption becomes higher depending on the connected peripheral equipment.

 

3.4 Communication specifications of Mitsubishi FX3U-422-BD

Item Specification
Transmission
standard
In conformance to RS-422
Maximum
transmission distance
50 m (164ft) maximum
Connection method 8-pin MINI DIN (female)
Communication
method
Half-duplex
Communication
format
Programming communication
Insulation Not insulated (Between communication line and CPU)

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX3U-422-BD.

It is 100% compatible with Mitsubishi original FX3U-422-BD.

 

Part#: FX3U-422-BD

The unit price is USD29.90/pc   buy buttom

 

USER'S MUNUAL PDF of communication board FX3U-422-BD:

RS-422 COMMUNICATION BOARD FX3U-422-BD

 

 FX3U-422-BD

 

Specification of communication board FX3U-422-BD:

Product Name Communication Board
Fit for for Mitsubishi FX3U PLC
Model No. FX3U-422-BD
Transmission Stanndard In Conformance to RS-422
External Connector Type Mini-DIN 8 Pin
Voltage DC 5V
Current 60mA
Max.Transmission Distance 50M
Material Metal, Plastic
Net Weight 14g
Package Content

1 x Communication Board

1 x Top Cover

2 x Install Screw

 

Description of communication board FX3U-422-BD:

  • The FX3U-422-BD interface adapters provide a second RS422 interface for connection of an additional device to the controller (programming unit or operator terminal).
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of communication board 

FX1N-232-BD FX1N-232-BD -1 FX2N-485-BD FX1N-USB-BD-1 FX3U-USB-BD FX3U-CNV-BD FX3U-485-BD FX3U-232-BD FX2N-485-BD+ FX2N-485-BD FX2N-232-BD FX1N-485-BD FX1N-422-BD FX2N-USB-BD-1 FX2N-422-BD

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com

 

Jul 20 2013

Mitsubishi FX3U-232-BD RS232 Board

Introduction to Mitsubishi FX3U-232-BD

FX3U-232-BD is a expansion board equipped with a 9-pin D-Sub for RS-232C communication. FX3U-232-BD exchanges data RS-232C devices.
 

1.1 Incorporated Items of Mitsubishi FX3U-232-BD

Product  RS-232C communication expansion board FX3U-232-BD
Included
items
M3 tapping screws for installation: 2 pcs.
Installation Manual (This manual)

 

1.2 Communication Function of Mitsubishi FX3U-232-BD

 Communication type    Function  
 Computer link    Data transfer via dedicated protocol between PLC and computer (specified as the master station).  
 Non-protocol communication   Serial communication via non-protocol between PLC and RS-232C device.  
 Programming communication    Programming communication via port of 232BD installed in PLC.  
 Remote maintenance    Program transfer or monitoring enabled via modem and phone line connected to serial port of PLC.  

 

1.3 External Dimensions and Part Names of Mitsubishi FX3U-232-BD

3

The communication port of the 232BD is 9-Pin D-Sub male type.

The table below shows the pin arrangement.

4

 

Installation of Mitsubishi FX3U-232-BD

INSTALLATION  PRECAUTIONS of Mitsubishi FX3U-232-BD

• Cut off all phases of the power source externally before starting the installation or wiring work, thus avoiding electric shock or damages to the product.

• Use the product in the environment within the general specifications described in PLC main unit manual (Hardware Edition).
Never use the product in areas with dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl2, H2S, NH3, SO2, or NO2), flammable gas, vibrations or impacts, or expose it to high temperature, condensation, or wind and rain.If the product is used in such a place described above, electrical shock, fire,malfunction, damage, or deterioration may be caused.
• Use screwdrivers carefully when performing installation work, thus avoiding accident or product damage.
• When drilling screw holes or wiring, cutting chips or wire chips should not enter ventilation slits.Such an accident may cause fire, failure or malfunction.
• Do not touch the conductive parts of the product directly, thus avoiding failure or malfunction.
• Fix the expansion board securely to the specified connector. Incorrect connection may cause malfunction.

 

The following explains the installation method to FX3U/FX3UC Series PLC (FX3U Series PLC is used for the following example).
For removing and installing details, refer to the PLC main unit manual. However, FX3UC Series PLC manual is only available in Japanese.

 

2.1 Installation Method of Mitsubishi FX3U-232-BD

5
• Refer to the procedure 2) for configuring a new system.
• Refer to the procedure 1) for adding product to an existing system.
1) Power off the PLC.
Disconnect all the cables connected to the PLC.
Dismount the PLC from the DIN rail.
2) Using a flat blade screwdriver as shown in the right figure, lift the little dummy expansion board cover (right fig. A). Do not damage the circuit board or electronic parts.
3) Remove the dummy expansion board cover (right fig. A) in a parallel motion away from the main unit.
4) Make sure the expansion board (right fig. B) is in parallel with the main unit (right fig. C) and fix it to the expansion board connector.
5) Fix the expansion board (right fig. B) to the main unit using the M3 tapping screws of the provided (right fig. D).
Tighten to a torque: 0.3 to 0.6 N⋅m

 

Specification of Mitsubishi FX3U-232-BD

STARTUP AND MAINTENANCE PRECAUTIONS of Mitsubishi FX3U-232-BD

• Do not disassemble or modify the unit.
  Doing so may cause failure, malfunction or fire.
  * For repair, contact your local Mitsubishi Electric distributor.
• Do not drop the product or do not exert strong impact, doing so may cause damage.

 

DISPOSAL PRECAUTIONS of Mitsubishi FX3U-232-BD

• Please contact a company certified in the disposal of electronic waste for environmentally safe recycling and disposal of the product.

 

TRANSPORT AND STORAGE PRECAUTIONS of Mitsubishi FX3U-232-BD

• During transportation avoid any impact as the product is a precision instrument.
  Check the operation of the product after transportation.

 

3.1 Applicable PLC of Mitsubishi FX3U-232-BD

Model name Applicability
FX3U Series PLC Ver.2.00 or later (from the first product)
FX3UC Series PLC  Ver.1.00 or later

Only one function expansion board can be used for one main unit.Two or more FX3U-232-BD cannot be used, or other expansion boards such as FX3U-422-BD or FX3U-485-BD cannot be installed/used together with FX3U-232-BD.

 

3.2 General Specifications of Mitsubishi FX3U-232-BD
General specifications are equivalent to the PLC main unit. For general specifications, refer to the following manual.
However, since the product is not isolated between communication lines and the CPU of main unit, please don't perform any dielectric withstand voltage test and insulation resistance test to this product.

 

3.3 Power supply specifications of Mitsubishi FX3U-232-BD
5V DC, 20 mA is supplied from the internal power supply in main unit.

 

3.4 Communication specifications of Mitsubishi FX3U-232-BD

Item Specification
Transmission
standard
In conformance to RS-232C
Maximum
transmission distance
15 m (49ft) maximum
Connection method 9-pin D-Sub type (male)
Indication (LED) RD, SD
Communication
method
Full-duplex
Communication
format
Non-protocol communication, computer link (dedicated
protocol format 1 and 4), and programming
communication
Baud rate Following baud rate can be specified when using
computer link or non-protocol communication: 300/600/
1200/2400/4800/9600/19200 bps
Insulation Not insulated (Between communication line and CPU)

 

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX3U-232-BD.

It is 100% compatible with Mitsubishi original FX3U-232-BD.

 

Part#: FX3U-232-BD

The unit price is USD29.90/pc   buy buttom

 

USER'S MUNUAL PDF of communication board FX3U-232-BD:

RS-232 COMMUNICATION BOARD FX3U-232-BD 

FX3U-232-BD

 

Specification of communication board FX3U-232-BD:

Product Name Communication Board
Fit for Mitsubishi FX3U PLC
Model NO. FX3U-232-BD
External Connector Type RS-232C DB9 Male Plug
Voltage DC 5V
Current 20mA
Max.Transmission Distance 15M
D-sub 9-pin Layout 1:CD;2:RD(RXD);3:SD(TXD);4:ER(DTR);5:SG(GND);6:DR(DSR);7,8,9:NC(not used)
Material Plastic, Metal
Net Weight 20g
Package Content

1 x Communication Board

1 x Top Cover

2 x Install Screw

 

Description of communication board FX3U-232-BD:

  • The communication modules for use with FX3U PLCs. The ADP modules fit on to the left hand side of the base unit while the BD modules clip into the front left corner of the base unit.
  • Port to connect a programming tool.
  • RS232C interface boards for Mitsubishi FX3U, anti-static and anti-surge.
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of communication board 

FX1N-USB-BD-1 FX3U-USB-BD FX3U-CNV-BD FX3U-485-BD FX3U-422-BD FX2N-485-BD+ FX2N-422-BD FX2N-USB-BD-1 FX1N-422-BD FX1N-485-BD FX2N-232-BD FX2N-485-BD FX1N-232-BD -1 FX1N-232-BD

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 19 2013

Mitsubishi FX1N-485-BD RS485 interface Board

Introduction to Mitsubishi FX1N-485-BD

The RS-485 communication board FX1N-485-BD (hereafter referred to as "485BD") is connected to the FX1S/FX1N Series PLC basic unit, and available for the applications described below.
Only one function expansion board can be connected to one PLC basic unit. Accordingly, the 485BD cannot be used together with the FX1N-422-BD or the FX1N-232-BD.

 

1.1 Features of Mitsubishi FX1N-485-BD
1) Data transfer function using the non-procedure method.
The 485BD transfers the data using the RS instruction between a bar code reader, personal computer or printer.
As the 485BD is not equipped with buffer memory, it sends and receives the data using data registers specified by the RS instruction.
For the RS instruction and the communication setting, refer to the FX Series Communication User’s Manual.
2) Data transfer function using a dedicated protocol.
The 485BD transfers the data when a personal computer directly specifies devices of the PLC.
For the dedicated protocol and the communication setting, refer to the FX Series Communication User’s Manual.
3) Parallel link function.
The 485BD transfers automatically 50 auxiliary relays and 10 data registers when two FX1S Series PLC’s (two FX1N Series PLC’s) are connected on a one-to-one basis.
For the setting procedure and program examples, refer to the FX Series Communication User’s Manual.
4) Easy PC link function.
The 485BD transfers automatically up to 64 auxiliary relays and 8 data registers when up to eight FX1S/FX1N/FX0N/FX2N/FX2NC Series PLC units are connected. For the setting procedure and program examples, refer to the FX Series Communication User’s Manual. For the FX2N Series PLC, the version should be 2.00 or greater (manufacturer’s serial No. 780000 or later).

 

1.2 Outside dimensions and name of each part for Mitsubishi FX1N-485-BD
 

1

 

1.3 System configuration of Mitsubishi FX1N-485-BD

For the system configuration, refer to the FX Series Communication User’s Manual offered separately.

 

Installation of Mitsubishi FX1N-485-BD
 

2.1 Installation procedure of Mitsubishi FX1N-485-BD
 

2
Make sure to turn off the power before installing the 485BD.
A) Communication board 485BD (function expansion board)
B) Connector for optional equipment
C)M3 screw to fix board (2 pieces) (offered as accessories of board)
D) Top cover for board (offered as an accessory of board)
E) M3 screw to fix top cover (offered as an accessory of board)
Note: This screw cannot be removed.
• Plug the communication board A) in to the connector B).
• Fix the board to the basic unit with two M3 screws C). (Tightening torque: 0.3 to 0.6 Nxm)
• Remove the top cover of the basic unit, and attach the top cover for board D) instead.
During attachment, remove D)’ with a nipper, etc. so that the connector of the board is exposed.
• Fix the top cover with the M3 screw E). (Tightening torque: 0.3 to 0.6 Nxm)
• When the FX1N-5DM is used also, refer to the handy manual offered with the FX1S/FX1N Series PLC main unit.
• Only one function expansion board is available for one FX1S/FX1N Series PLC basic unit. Never stack up two or more function expansion boards. (Even if they are stacked up, they do not function at all.)

 

Specifications of Mitsubishi FX1N-485-BD

3.1 Environmental specifications of Mitsubishi FX1N-485-BD
The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of the PLC main unit.)


3.2 Power supply specifications of Mitsubishi FX1N-485-BD
5V DC, 60 mA is supplied as the power from the PLC.


3.3 Performance specifications of Mitsubishi FX1N-485-BD

Transmission standard Description
Maximum transmission
distance
In conformance to RS-485 and RS-422
Communication type Non-procedure, dedicated protocol, parallel link, easy PC link: Half
duplex, bi-directional
Communication method Non-procedure, dedicated protocol 1 procedure, dedicated protocol 4
procedure, parallel link, easy PC link
Transmission speed
(baud rate)
Non-procedure, dedicated protocol: 300 to 19,200 b ps
Parallel link: 19,200(b ps)
Easy PC link: 38,400(b ps)
Insulation Not insulated

 

Guidelines for the safety of the user and protection to the RS-485 Communication Board FX1N-485-BD
• This manual has been written to be used by trained and competent personnel. This is defined by the European directives for machinery, low voltage and EMC.
• If in doubt at any stage during the installation of the RS-485 Communication Board FX1N-485-BD always consult a professional electrical engineer who is qualified and trained to the local and national standards. If in doubt about the operation or use of the RS-485 Communication Board FX1N-485-BD please consult the nearest Mitsubishi Electric distributor.
• Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment.
• All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
• Owing to the very great variety in possible application of this equipment, you must satisfy yourself as to its suitability for your specific application. 

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX1N-485-BD.

It is 100% compatible with Mitsubishi original FX1N-485-BD.

 

Part#: FX1N-485-BD

The unit price is USD21.69/pc  buy buttom

 

USER'S MUNUAL PDF of Mitsubishi communication board FX1N-485-BD:

RS-485 COMMUNICATION BOARD FX1N-485-BD

 

FX1N-485-BD

 

Specification of Mitsubishi communication board FX1N-485-BD:

Product Name Communication Board
Fit for Mitsubishi FX1N PLC
Model NO. FX1N-485-BD
External Connector Type In Conformance to RS-485
Voltage DC 5V
Current 40mA
Max.Transmission Distance 15M
Communication Method Half-duplex
Insulation No Insulated
Material Plastic, Metal
Net Weight 18g
Package Content

1 x Communication Board

1 x Top Cover

Several Install Parts

 

Description of RS485 Communication Board for Mitsubishi FX1N-485-BD:

  • The FX1N combines the benefits of an inexpensive compact controller with the flexible expansion capabilities of a modular control system.
  • This is a Replacement of Mitsubishi FX1N-485-BD Programmable Controller.
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of communication board 

FX1N-USB-BD-1 FX3U-USB-BD FX3U-CNV-BD FX3U-485-BD FX3U-422-BD FX3U-232-BD FX2N-485-BD+ FX2N-485-BD FX2N-232-BD FX1N-422-BD FX2N-USB-BD-1 FX2N-422-BD FX2N-485-BD FX1N-232-BD -1 FX1N-232-BD

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 18 2013

Mitsubishi FX1N-422-BD RS422 interface Board

Introduction to Mitsubishi FX1N-422-BD


The RS-422 communication board FX1N-422-BD (hereafter reaferred to as "422BD") is connected to the FX1S/FX1N
Series PLC basic unit, and used as a connection port for a programming tool (such as the GOT Series, the ET Series,programming tool FX-10P/20P or personal computer).
For example, by using the 422BD, two GOT Series units can be connected to the FX1S/FX1N Series PLC, or the GOT Series unit can be connected to a programming tool (such as FX-10P, FX-20P or personal computer). However, a programming tool can be connected to only either one between the connector built in the PLC and the connector of the 422BD.
Only one function expansion board can be connected to one PLC basic unit. Accordingly, the 422BD cannot be used together with the FX1N-485-BD or the FX1N-232-BD.

 

Outside Dimensions and Name of Each Part of Mitsubishi FX1N-422-BD

32

 

Connectable Models and Cables of Mitsubishi FX1N-422-BD

Peripheral equipment   Cable   Current consumption of 5V DC  
FX-20P   FX-20P-CAB0 or
(FX-20P-CAB + FX-20P-CADP)
180mA  
FX-10P   120mA  
Personal computer (for programming)   {F2-232CAB (for D-sub, 25-pin type),
F2-232CAB-1 (for D-sub, 9-pin type) or
F2-232CAB-2 (for half-pitch, 14-pin type)}
+ FX-232AW(C) + FX-422CAB0
220mA  
FX-10DM   FX-20P-CAB0 or FX-20P-CAB + FX-20P-CADP   180mA  
F930GOT, F940GOT,
ET-940, F940/943GOT
(handy type)
FX-50DU-CAB0   Not required  
FX-40DU-CAB(-10M) (or equivalent cable) + FX-422AW0 180mA

 

Installation of Mitsubishi FX1N-422-BD

31
Make sure to turn off the power before installing the 422BD.
A) Communication board 422BD (function expansion board)
B) Connector for optional equipment
C) M3 screw to fix board (2 pieces) (offered as accessories of board)
D) Top cover for board (offered as an accessory of board)
E) M3 screw to fix top cover (offered as an accessory of board)
Note: This screw cannot be removed.
• Plug the communication board A) in to the connector B).
• Fix the board to the basic unit with two M3 screws C). (Tightening torque: 0.3 to 0.6 Nžm)
• Remove the top cover of the basic unit, and attach the top cover for board D) instead.
During attachment, remove D)’ with a nipper, etc. so that the connector of the board is exposed.
• Fix the top cover with the M3 screw E). (Tightening torque: 0.3 to 0.6 Nžm)
• When the FX1N-5DM is used also, refer to the handy manual offered with the FX1S/FX1N Series PLC main unit.
• Only one function expansion board is available for one FX1S/FX1N Series PLC basic unit. Never stack up two or
more function expansion boards. (Even if they are stacked up, they do not function at all.)


Specifications of Mitsubishi FX1N-422-BD
5.1 Environmental specifications
of RS422 interface PLC Communication Board

The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of the PLC main unit.)


5.2 Power supply specifications of RS422 interface PLC Communication Board
5V DC, 60 mA is supplied as the power from the PLC.
For the details, refer to the handy manual of the PLC main unit.


5.3 Performance specifications  of RS422 interface PLC Communication Board

Transmission standard In conformance to RS-232C
Maximum transmission distance 50 m maximum
External equipment connection method Mini-DIN, 8-pin socket
D-sub 9-pin Layout 1: CD 2: RD(RXD) 3: SD(TXD) 4: ER(DTR) 5: SG(GND)
6: DR(DSR) 7, 8, 9: NC (not used)
Communication method Half duplex, bi-directional
Protocol Protocol for programming tool
Isolation No insulated

 

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX1N-422-BD.

It is 100% compatible with Mitsubishi original FX1N-422-BD.

 

Part#: FX1N-422-BD

The unit price is USD21.69/pc   buy buttom

 

USER'S MUNUAL PDF of communication board FX1N-422-BD: 

FX1N-422-BD-USER'S MANUAL

FX1N-422-BD

 

Specification of communication board FX1N-422-BD:

Product Name Communication Board
Fit for for Mitsubishi FX1N PLC
Model No. FX1N-422-BD
Transmission Stanndard In Comformance to RS-422
External Connector Type Mini-DIN 8 Pin
Voltage DC 5V
Current 60mA
Max.Transmission Distance 50M
Material Metal, Plastic

 

Description of communication board FX1N-422-BD:

  • The RS-422 communication board FX1N-422-BD (hereafter referred to as "422BD") is connected to the FX1S/FX1N Series PLC basic unit, and used as a connection port for a programming tool (such as the GOT Series,the ET Series,programming tool FX-10P/20P or personal computer).
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of communication board 

FX1N-USB-BD-1 FX3U-USB-BD FX3U-CNV-BD FX3U-485-BD FX3U-422-BD FX3U-232-BD FX2N-485-BD+ FX2N-485-BD FX2N-232-BD FX1N-485-BD FX2N-USB-BD-1 FX2N-422-BD FX1N-232-BD FX1N-232-BD -1

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 17 2013

Mitsubishi FX2N-422-BD RS422 interface Board

Introduction to Mitsubishi FX2N-422-BD

The FX2N-422-BD for RS422 communication board (422BD) can be connected to an FX2N Series programmable
controller, and used as a port for programming and monitoring tools.
When the 422BD is used, two DU Series units can be connected to the FX2N or a DU Series unit and a
programming tool. However, only one programming tool can be connected at once.
Only one 422BD can be connected to a base unit. Also, the 422BD cannot be used together with the
FX2N-485-BD or the FX2N-232-BD.

 

External Dimensions of Mitsubishi FX2N-422-BD

Dimensions : mm (inches) Accessory : M3 self-tapping screws ´ 2

10

 

Suitable Products and Connecting Cables for Mitsubishi FX2N-422-BD

 Product    Connecting cable    Required 5V DC  
 FX-20P-E   FX-20P-CAB0 or FX-20P-CAB + FX-20P-CADP    180mA  
 FX-10P-E    120mA  
 Personal computer   F2-232CAB-1 + FX-232AW(C) + (FX-422ACB0 or
FX-422CAB + FX-20P-CADP) *1
 220mA  
 FX-10DU-E   FX-20P-CAB0 or FX-20P-CAB + FX-20P-CADP    220mA  
 FX-20DU-E   FX-20DU-CAB0 or FX-20DU-CAB + FX-20P-CADP    180mA  
 FX-25DU-E,FX-30DU-E,
 FX-40DU-ES,FX-40DU-TK-ES,
 FX-50DU-TK(S)-E *2 
FX-50DU-CAB0 or FX-40DU-CAB + FX-20P-CADP  

 30mA  

*1: When using other products or cables please check the product manual for required 5V DC supply.
*2: FX-2PIF can not be connected to the FX2N-422-BD.

 

Mounting procedure for using Mitsubishi FX2N-422-BD

11

 

Specification of Mitsubishi FX2N-422-BD
5.1 General specification of RS422 interface PLC communication Board
General specifications are the same as those for the FX2N series programmable controller.


5.2 Power supply specification of RS422 interface PLC communication Board
The 422BD requires 60mA 5V DC supplied from the programmable controller.
The 5V DC power capacity of the programmable controller is 290 mA maximum. This is used by peripheral units and special function blocks as well as the 422BD. Make sure that the power capacity does not exceed this value. For the details, refer to the hardware manual.
For additional current consumption increases, refer to section 3.

 

5.3 Performance specification of RS422 interface PLC communication Board

Interface Conforming to RS422
Maximum transfer distance Total extension within 50m.
Connector MINI DIN 8 pin
Communication method Half-duplex communication system
Protocol Programming protocol
Isolation No isolation

 

Cautions for using Mitsubishi FX2N-422-BD
1) When using any 422BD, do not use any other communication format or parameters. If the communication format or parameters is set, programming is not possible.
2) Only one programming tool (such as FX-10P, FX-20P, etc.) should be connected to either the programming port or the port provided on the 422BD. If a programming tool is connected to both connectors, the following may occur.
a) The program inside the programmable controller may not be consistent with the program inside the programming tool. If the program is modified or the set value for timers or counters is modified, a part of the program may be damaged and the programmable controller may malfunction.
b) When the sampling trace function of the programmable controller is used from both ports, the correct sampling trace result cannot be obtained.

 

Diagnostics of Mitsubishi FX2N-422-BD
1) Make sure that the cable connected is correct.
2) Make sure that the programmable controller is connected, and that the POWER LED is on.
3) Make sure that the communication format is in the initial state (D8120 = K0). Check using a peripheral unit how the communication parameters are set. If the no protocol (RS instruction) or the dedicated protocol is selected, set the parameters correctly using the peripheral unit.
4) Make sure that the RS, VRRD or VRSC instruction or N:N network setting program is not used in the program. If such an instruction is used in the program, delete it, turn off the power of the programmable controller, then turn it on again.
5) If the special auxiliary relay M8070 or M8071 is turned on, turn off the relay using the peripheral unit, turn off the power of the programmable controller, then turn on the power again.

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX2N-422-BD.

It is 100% compatible with Mitsubishi original FX2N-422-BD.

Part#: FX2N-422-BD

The unit price is USD17.65/pc  buy buttom

 

USER'S MUNUAL PDF OF RS422 interface PLC Communication Board FX2N-422-BD:

FX2N-422-BD-USER'S MANUAL

FX2N-422-BD

 

Specification of communication board FX2N-422-BD:

Interface Conforming to RS422
Maximum transfer distance Total extension within 50m.
Connector MINI DIN 8 pin
Communication method Half-duplex communication system
Protocol Programming protocol
Isolation No isolation
   
Product Name Communication Board
Fit for Mitsubishi FX2N PLC
Model NO. FX2N -422-BD
Interface Conforming to RS422
Connector Type Mini Din 8 Pin
Voltage DC 5V
Current 60mA
Max.Transmission Distance 50M
Communication Method Half-duplex(Communication System)
Insulation No Insulated
Material Plastic, Metal

 

Description of communication board FX2N-422-BD:

  • The FX2N-422-BD for RS-422 Communication Board(422BD)can be connected to an FX2N series programmable controller, and used as a port programming and monitoring tools.
  • This is a Replacement of Mitsubishi FX2N-422-BD Programmable Controller.
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of Communication Board 

FX2N-USB-BD-1 FX1N-422-BD FX1N-485-BD FX2N-232-BD FX2N-485-BD FX2N-485-BD+ FX1N-USB-BD-1 FX3U-USB-BD FX3U-CNV-BD FX3U-485-BD FX3U-422-BD FX3U-232-BD

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 16 2013

Mitsubishi FX2N-232-BD RS232 interface Board

Introduction to Mitsubishi FX2N-232-BD

 

The communication board FX2N-232-BD for RS232C (hereinafter referred to as “232BD”) can be connected to the main unit of the FX2N Series programmable controller, and used as the port for the following applications.
(1) To perform data transfer between RS232C devices such as personal computers, bar code readers and printers.
(2) To perform data transfer using the dedicated protocol between RS232C devices. For details of the dedicated protocol, refer to the users manual of the FX-485PC-IF.
(3) To connect a programming tool.
And when the 232BD is used for the application (1) or (2) above, the communication format including the baud rate, the parity and the data length is specified by the parameters or the contents of the special data register D8120 of the FX2N programmable controller.
Only one 232BD can be connected to one base unit. Accordingly, the 232BD cannot be used together with the FX2N-485-BD or the FX2N-422-BD. When two or more RS232C units are required to be connected for the application, use the special block for RS232C communication.

 

1.1 EXTERNAL DIMENSIONS of Mitsubishi FX2N-232-BD
Dimensions : mm (inches) Accessory : M3 self-tapping screws ´ 2, mounting bracket ´ 2

23

 

TERMINAL LAYOUTS of Mitsubishi FX2N-232-BD

The connector is a 9-pin D-SUB type, and the pin configuration is as shown below.

24

Pin No. Signal Meaning Function
1 CD(DCD) CD(DCD) ON when carrier is detected for data reception
2 RD(RXD) Receive data Receive data (RS232C device to 232BD)
3 SD(TXD) Send data Send data (232BD to RS232C device)
4 ER(DTR) Send request Signal requesting preparation for data sending to RS232C
device
5 SG(GND) Signal ground Signal ground
6 DR(DSR) Send enable Shows RS232C device is ready to receive
7,8,9 NC No connection

 

SPECIFICATION of Mitsubishi FX2N-232-BD

3.1 General specification of RS232 interface PLC comunication Board
General specifications is same as those for the FX2N series programmable controller.


3.2 Power supply specification of RS232 interface PLC comunication Board
5 V DC, 60 mA is required from the programmable controller.


3.3 Specification of RS232 interface PLC comunication Board

Transmission standard Conforming to RS232C
Transmission distance Max. 15m
Connector 9-pin D-SUB type
Pin layout of connector 1:CD(DCD) 2:RD(RXD) 3:SD(TXD) 4:ER(DTR) 5:SG(GND) 6:DR(DSR)
7,8,9:NC(No connection)
LED indicators RXD, TXD
Communication method Half-duplex communication system
Protocol Programming protocol, dedicated protocol (format 1 or 4), non protocol
Isolation No isolation

 

3.4 Related flag and data registers of RS232 interface PLC comunication Board

Diagnostic   devices Operation
M8121  Data transmission delayed (RS instruction)
M8122  Data transmission flag (RS instruction)
M8123  Finished receiving data (RS instruction)
M8124  Carrier detection flag (RS instruction)
M8126  Global flag (dedicated protocol)
M8127  On demand handshake flag (dedicated protocol)
M8128 On demand error flag (dedicated protocol)
M8129  On demand Byte/Word flag (dedicated protocol)
M8161  Selection of 8 bit operations for applied instructions
ASC, RS, ASCI, HEX, CCD (RS instruction)
   
Diagnostic devices Operation
D8120  Communications format (RS instruction, dedicated protocol)
D8121  Local station number (dedicated protocol)
D8122  Amount of data to be transmitted (RS instruction)
D8123  Amount of remaining data already received (RS instruction)
D8124  Data header <default STX (02H)> (RS instruction)
D8125  Data terminator <default ETX (03H)> (RS instruction)
D8127  On demand head device register (dedicated protocol)
D8128  On demand data length register (dedicated protocol)
D8129  Data network ‘time-out’ timer value (dedicated protocol)

 

3.5 Communication format D8120  of Mitsubishi FX2N-232-BD
To send and receive the data between the RS232C unit using the 232BD, the communication format including the
transmission speed (baud rate) and the parity must be consistent between the 232BD and the RS232C unit.
The communication format can be set using parameters or the contents of special data register D8120 of the FX2N programmable controller. Make sure to set appropriately the communication format in accordance with the RS232C unit used. For the setting method using the parameters of the FX2N programmable controller, refer to the manual of the peripheral unit used.
Make sure to turn off the power of the programmable controller and turn it on again after modifying the setting.

25

*1 Set to “0" when using the dedicated protocol.
*2 Effective only when no protocol (RS instruction) is selected, and has an initial value of STX (02H: Can be modified by
the user).
*3 Effective only when no protocol (RS instruction) is selected, and has an initial value of ETX (03H: Can be modified by
the user).
*4 Set to (b11, b12) = (1, 0) when using the dedicated protocol.
*5 Set to “0" when using no protocol. 

 

3.5.1 Example program of setting of Mitsubishi FX2N-232-BD
26

The control line is set by b12.
b12 = 0 : No hardware hand shaking. Send and receive are controlled by software protocol.
b12 = 1 : Hardware hand shaking. Signal lines ER(DTR)and DR(DSR)are used to control send and receive of data.

27

 

WIRING of Mitsubishi FX2N-232-BD

To connect the 232BD to RS232C device use an RS232C cable. Make sure that the shield of cables is connected to
ground (100 W or less).
The connector of the 232BD is 9-pin D-SUB (see Section 1.2 and Chapter 2). The connections of RS232C devices
varies with each device being used. Check the specification of the device, and connect.
4.1 Connection examples
4.1.1 Terminal specification device
of RS232 interface PLC comunication Board

28

 

4.1.2 Modem specification device of RS232 interface PLC comunication Board

29

 

4.1.3 When programming or monitoring of Mitsubishi FX2N-232-BD
Use F2-232CAB-1 and 25-pin D-SUB to 9-pin D-SUB adapter or make a suitable cable.

 

CAUTION for using Mitsubishi FX2N-232-BD

1) When programming tool is connected the 232BD, do not use any other communication format or parameters. If communication format or parameters is set, programming is not possible.
2) Only one programming tool (such as FX-10P, FX-20P, etc.) should be connected to either the programming port or the port provided on the 232BD. If a programming tool is connected to both connectors, the following may occur.
a) The program inside the programmable controller may not be consistent with the program inside the programming tool. If the program is modified or the set value for the timer or the counter is modified, a part of the program may be damaged and the programmable controller may malfunction.
b) When the sampling trace function of the programmable controller is used from both ports, the correct sampling trace result cannot be obtained.

 

Our company (Kollewin Technology CO., Limited) have a new product, named FX2N-232-BD.

It is 100% compatible with Mitsubishi original FX2N-232-BD.

 

Part#: FX2N-232-BD

The unit price is USD17.65/pc   buy buttom

 

USER'S MUNUAL PDF of Mitsubishi communication board FX2N-232-BD:

FX2N-232-BD-USER'S MANUAL

 

FX2N-232-BD

 

Specification of communication board FX2N-232-BD:

Product Name Communication Board
Fit for for Mitsubishi FX1N PLC
Transmission Stanndard Comforing to RS232C
Connector Type Male 9 pin D-SUB
Voltage DC 5V
Current 60mA
Max.Transmission Distance 15M
D-sub 9-pin Layout 1:CD;2:RD(RXD);3:SD(TXD);4:ER(DTR);5:SG(GND);6:DR(DSR);7,8,9:NC(not used)
Material Metal, Plastic

 

Description of communication board FX2N-232-BD:

 

  • Port to transfer the data using the non-procedure method between diversified RS-232C equipment such as personal computer, bar code reader and printer.
  • Port to transfer the data using a dedicated protocol between an RS-232C equipment.
  • Port to connect a programming tool.
  • RS232C interface boards for Mitsubishi FX1N, anti-static and anti-surge.
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

 

More pictures of Communication Board

FX1N-USB-BD-1 FX3U-USB-BD FX3U-CNV-BD FX3U-485-BD FX3U-422-BD FX3U-232-BD FX2N-485-BD+ FX2N-485-BD FX1N-485-BD FX1N-422-BD FX2N-USB-BD-1 FX2N-422-BD

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com