USB/MPI+ V2.0:USB isolated adapter for Siemens S7-300/400 PLC, replace 6ES7 972-0CB20-0XA0

USB/MPI+ V2.0:USB to RS485 isolated adapter for SIEMENS S7-200/300/400 PLC,replace 6ES7 972-0CB20-0XA0

 

6ES7 972-0CB20-0XA0          SIMATIC S7, PC ADAPTER USB

SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT

Please read below data sheet of Siemens original 6ES7972-0CB20-0XA0:

SIMATIC S7-400, S7-300, S7-200, ET 200, SIMATIC HMI

-

SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT
Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 100 mA
Power
Power consumption, typ. max. 2.5 W
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes; 6 kV, contact discharge (to IEC 61000-4-2); 8 kV, air discharge (to IEC 61000-4-2)
Interference immunity to cable-borne interference
on the supply lines acc. to IEC 61000-4-4 Yes; 2 kV (to IEC 61000-4-4, burst)
Interference immunity on signal lines acc. to IEC 61000-4-4 Yes; 1 kV (to IEC 61000-4-4; burst; length < 3 m); 2 kV (to IEC 61000-4-4; burst; length > 3 m)
Surge immunity
on the supply lines acc. to IEC 61000-4-5 Yes; 1 kV (to IEC 61000-4-5; surge symm.); 2 kV (to IEC 61000-4-5; surge asymm.)
Immunity against high-frequency electromagnetic fields
Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 Yes; 10 V/m, 80 to 1000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3)
Immunity against conducted interference induced by high-frequency fields
Interference immunity against high frequency current feed acc. to IEC 61000-4-6 Yes; 10 V, 9 kHz to 80 MHz (to IEC 61000-4-6)
Immunity to magnetic field interference
Interference immunity to magnetic fields at 50 Hz 30 A/m; to IEC 61000-4-8
Emission of radio interference acc. to EN 55 022
Interference emission acc. to EN 55022, class B Yes
Ambient conditions
Operating temperature
Min. 5 °C
max. 40 °C
Permissible temperature change 10 °C/h; Operation: 10 K/h; storage/transport: 20 K/h
Storage/transport temperature
Min. -20 °C
max. 60 °C
Relative humidity
Operation, min. 5 %
Operation, max. 80 %; At 25 °C (no condensation)
Storage/transport, min. 5 %
Storage/transport, max. 95 %; At 25 °C (no condensation)
Vibrations
Operation, checked according to IEC 60068-2-6 Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 500 Hz: Acceleration 9.8 m/s2
Transport tested checked to IEC 60068-2-6 Yes; (packed) 5 to 9 Hz, amplitude 3.5 mm; 9 to 500 Hz, acceleration 9.8 m/s2
Shock test
Shock test Tested to DIN IEC 60068-2-2; Operation: 950 m/s2 (10 g), 30 ms, 100 Shocks; Transport (packaged): 250 m/s2 (25 g), 6 ms, 1000 shocks
Dimensions
Width 105 mm
Height 58 mm
Depth 26 mm
Weight
Weight, approx. 100 g

 

Our company have the compatible cable, named USB/MPI+ V2.0,  can replace Siemens 6ES7 972-0CB20-0XA0.

Below is the picture of our compatible OEM product USB/MPI+ V2.0:

USB-MPI+ V2.0-4

You can get it only need USD90.00/pc.    Buy now ====>buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

 

 

This is USB/MPI+ V2.0 only for Siemens S7-300/400 PLC.

Optoelectronic isolated USB/MPI V2.0,Siemens S7-300/400 PLC Programming adapter cable,3 meters,with communication indicator,can replace Siemens 6ES7 972-0CB20-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.It doesn’t support profibus function.

USB/MPI+ is the optoelectronic isolated adapter for industrial design. There is anti-surging& anti-lightning protection circuit for the USB and RS485 interface. It support hot plug. It‘s suitable for the communication between Siemens S7-300/400 series PLC or other equipments with MPI interface and computer. In particular, it applies to the strong interfere industrial scene and the safeguard in the circuit guarantees the safely running of the system.

USB/MPI+ programming cable simulate USB port as traditional serial port (usually COM3), which enables existing programming software(STEP 7) to communicate through simulated traditional port and PLC devices.

 

Outline configuration:

signals definition of the RS485-Block (DB9M) of the USB/MPI +

pin

signal

Description

1

NC

No use

2

M24V

24VDC power negative

3

B

RS485 signals positive

4

RTSAS

Data reception control

5

GND

RS485 Signal Ground

6

NC

No use

7

P24V

24VDC power positive

8

A

RS485 signals negative

9

RTS_PG

Data sent control

 

Functions
● Support Windows2000/Windows XP
● Support STEP7 V5.2 and higher
● Fully compatible with USB V1.1 and USB V2.0
● Power supply by both USB main line and MPI programming port(Total 1W).with Overcurrent Protection and Surge Protection
● High optoelectronic isolation voltage up to 1000VDC
● The USB port design with surge protection .The RS485 port design with overcurrent protection and lightning protection(500W)
● Baud rate of Com port on PC: 19.2Kbps~115.2Kbps
● Baud rate of MPI port on PLC: 19.2Kbps~187.5Kbps
● Support long distance communication up to 1000m
● Working temperature -20~+75′C
● Length 3 meters.Color:black
● One pc supports one USB programming cable only
System requirement
Please make sure your PC is IBM PC compatible and has the following
system requirements before using the USB programming cable.
● Intel is compatible with 586DX4-100MHz CPU or higher
● A standard USB port (4-pin A plug)
● Operating system is Windows2000 or Windows XP

Usage:
USB device drivers should be installed before using USB/MPI+ programming cable. After completing Driver installation, the corresponding COM port for the USB/MPI+ programming cable will be displayed in the  Device Manager of Window. The step next is just to choose this COM port in the programming software and other application software and keep other communication parameters as in the Default settings. And the following steps are exactly the same as in the traditional programming cables with RS232 interfaces. Here are requested to indicate that “USB” option in the local communications interface setting which the software is not support to the programming cable.

If the COM port in the programming software with “*” symbols, such as “* COM3″, it’s shown that the COM port have faults. Quit the software and plug a USB plug or re-install the USB driver.

Please note that Siemens COM port in programming software is up to support the option to COM8.But the ports more than COM8 are able to choose but in fact can not be used!

STEP7 software settings:
Enter the main interface of STEP7 programming software (SIMATIC Manager), click on the “Set PG / PC Interface ” option under “Options” menu into the PG / PC interface settings.

1, Double-click on “PC Adapter (MPI)” to set the parameters of COM port and MPI port. The adapter does not support “PC Adapter (PROFIBUS)” option.

2, Click on “Local Connection” option to set the parameters of COM port, correct choose the COM port in the equipment manager after the driver of USB / MPI + USB has been installed, select the 19200 bps or 38400 bps as the baud rate of COM Communication. USB / MPI + will automatically adapt to the choice of baud rate.

3, Click “MPI” to set the parameters of MPI interface adapter options, baud rate can be set to 187.5 Kbps, or 19.2 Kbps, USB / MPI + adapter will automatically adapt to the MPI port of the PLC baud rate. Other parameters set as default.

4, On-line test can access the points: USB / MPI + connect the MPI port of the S7-300/400PLC with the computer’s USB port. Click on the main menu interface, as shown in a red circle button. If the data in red box is shown as the picture, the on-line test has pasted. As so far, the setting has completely finished. It can do all Operation such as upload, download ,monitoring of the procedures and other operations.

Long-distance communications:

For USB/MPI+, the largest communication distance is up to 1000m at the communication speed of 187.5Kbps. It needs to splice 120ohm terminal resistance between 3 and 8 pin on the RS485 port(DB9 Male) to eliminate signal reflection, and connect 24VDC power between 7 and 2 pin. But requires one PFB-G for each PLC.

Please Note: USB interface cable cannot be extended.

The quality is guaranteed.It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

 

Any question, please feel free to contact me.

May 15 2013

USB/MPI+ V4.0:USB to RS485 isolated adapter for SIEMENS S7-200/300/400 PLC,replace 6ES7 972-0CB20-0XA0

USB/MPI+ V4.0:USB to RS485 isolated adapter for SIEMENS S7-200/300/400 PLC,replace 6ES7 972-0CB20-0XA0

 

6ES7 972-0CB20-0XA0          SIMATIC S7, PC ADAPTER USB

SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT

Please read below data sheet of Siemens original 6ES7972-0CB20-0XA0:

SIMATIC S7-400, S7-300, S7-200, ET 200, SIMATIC HMI

-

SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT
Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 100 mA
Power
Power consumption, typ. max. 2.5 W
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes; 6 kV, contact discharge (to IEC 61000-4-2); 8 kV, air discharge (to IEC 61000-4-2)
Interference immunity to cable-borne interference
on the supply lines acc. to IEC 61000-4-4 Yes; 2 kV (to IEC 61000-4-4, burst)
Interference immunity on signal lines acc. to IEC 61000-4-4 Yes; 1 kV (to IEC 61000-4-4; burst; length < 3 m); 2 kV (to IEC 61000-4-4; burst; length > 3 m)
Surge immunity
on the supply lines acc. to IEC 61000-4-5 Yes; 1 kV (to IEC 61000-4-5; surge symm.); 2 kV (to IEC 61000-4-5; surge asymm.)
Immunity against high-frequency electromagnetic fields
Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 Yes; 10 V/m, 80 to 1000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3)
Immunity against conducted interference induced by high-frequency fields
Interference immunity against high frequency current feed acc. to IEC 61000-4-6 Yes; 10 V, 9 kHz to 80 MHz (to IEC 61000-4-6)
Immunity to magnetic field interference
Interference immunity to magnetic fields at 50 Hz 30 A/m; to IEC 61000-4-8
Emission of radio interference acc. to EN 55 022
Interference emission acc. to EN 55022, class B Yes
Ambient conditions
Operating temperature
Min. 5 °C
max. 40 °C
Permissible temperature change 10 °C/h; Operation: 10 K/h; storage/transport: 20 K/h
Storage/transport temperature
Min. -20 °C
max. 60 °C
Relative humidity
Operation, min. 5 %
Operation, max. 80 %; At 25 °C (no condensation)
Storage/transport, min. 5 %
Storage/transport, max. 95 %; At 25 °C (no condensation)
Vibrations
Operation, checked according to IEC 60068-2-6 Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 500 Hz: Acceleration 9.8 m/s2
Transport tested checked to IEC 60068-2-6 Yes; (packed) 5 to 9 Hz, amplitude 3.5 mm; 9 to 500 Hz, acceleration 9.8 m/s2
Shock test
Shock test Tested to DIN IEC 60068-2-2; Operation: 950 m/s2 (10 g), 30 ms, 100 Shocks; Transport (packaged): 250 m/s2 (25 g), 6 ms, 1000 shocks
Dimensions
Width 105 mm
Height 58 mm
Depth 26 mm
Weight
Weight, approx. 100 g

 

Our company have the compatible cable, named USB/MPI+ V4.0,  can replace Siemens 6ES7 972-0CB20-0XA0.

Below is the picture of our compatible OEM product USB/MPI+V4.0:

USB-MPI+V4.0

You can get it only need USD99.99/pc.    Buy now ====> buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Introduction

USB/MPI+ V4.0 is the USB to MPI and PPI protocol adapter, support S7-300/400 PLC MPI or S7-200 PLC PPI communication. It’s the same as Siemens PC Adapter USB except that this USB/MPI+ V4.0 doesn’t support profibus communication. Its driver is the Siemens PC_Adapter_USB driver, and choose the USB port, not the COM port.

The working power supply of this cable USB/MPI+ V 4.0 is directly from the USB port, but not the PLC programming interface.

USB/MPI+ V 4.0 is the optoelectronic isolated adapter for industrial design. There is anti-surging& anti-lightning protection circuit for the USB and RS485 interface. It support hot plug. It’s suitable for S7-300/400/200 series PLC. In particular, it applies to the strong interfere industrial scene and the safeguard in the circuit guarantees the safely running of the system.

USB/MPI+ principle and figure structure:
USB-MPI

 

 

Indicator ON Flash Off
PWR USB Power On Error Error Or Power off
RxD Error Data exchange from PLC Not Connected
TxD Error Data exchange to PLC No Data exchange

 

Indicator State

 

Functions
●    Support STEP7 V5.2 and higher,STEP7 Micro/Win 4.0 and higher
●    Fully compatible with USB V2.0
●    Power supply by USB port(100mA). with overcurrent Protection and Surge Protection
●    High optoelectronic isolation voltage up to 1000VDC
●    The USB port design with surge protection.
●    The RS485 port design with overcurrent protection and lightning
protection:Ipp=100A(10/700us,4KV) .Accord to the standard:ITU-TK20/21,VDE0433. ±15KV ESD Protection.
●    Baud rate of MPI port on PLC: 19.2Kbps,187.5Kbps,1.5Mbps. automatically adjust.
●    Baud rate of PPI port on PLC: 9.6Kbps,19.2Kbps,187.5Kbps.
automatically adjust.
●    Support long distance communication up to 1000m
●    Working temperature -20~+75′C
●    Length 3 meters.Color:black
●    One pc supports one USB programming cable only

About Long Distance Communication
For USB/MPI+ V4.0, the largest communication distance is up to 1000m at the communication speed of 187.5Kbps. It needs to splice 120ohm terminal resistance between 3 and 8 pin on the RS485 port(DB9 Male) to eliminate signal reflection. But requires one PFB-G for each PLC.

 

USB-MPI

 

Please contact me if you have any question.

May 13 2013

ES-ETH-SC09:Mitsubishi FX series PLC Ethernet adapter

ES-ETH-SC09:Mitsubishi FX series PLC Ethernet adapter

ES-ETH-SC09

Description:

Mitsubishi FX series PLC Ethernet adapter,is used for the communication between FX series PLC and Ethernet,Internet or 3G wireless network by the programming interface.No need to revise the communication protocol and software,support Dynamic DNS,user can remote control the PLC by the internet. The RJ45 port and RS422 interface are isolated in order to suit harsh environment in the industrial scene.

ES-ETH-SC09 is the industrial product which use the Ethernet and Internet or 3G wirelss internet to achieve Mitsubishi FX series PLC networking communication It integrates a number of complex network protocols, supports TCP Server, TCP Client, UDP unicast, UDP multicast etc many modes,.It has 10M/100M adaptive Ethernet interface and RS422 interface which meets Mitsubishi technical specifications, You only need to go on simple setting and then let the FX PLC go on Ethernet/Internet communication.

Mitsubishi FX Series PLC refers to FX0/FX0S/FX0N/FX1N/FX2N/FX3U/FX3G … …. .

ES-ETH-SC09 is an industrial grade product, its RJ45 port and RS422 interface are both isolated in order to suit harsh environment in the industrial situations. Especially each signal pin has anti-static protection and surge protection, which can effectively protect the PLC communication port from outside surges and the impact of common-mode inductance.

Notice:when the ES-ETH-SC09 is used to communicate between  the PC and the FX series PLC or between PLC and PLC, it supports the  RS422/RS485/RS232 communication which meet UART serial data communication standard. Some field buses such as PROFIBUS, PPI, MPI, CC-Link, PC-Link, etc., although the physical interface is RS485, they do not comply with the UART serial data format, so they do not apply to this product!
◆ High-speed, highly reliable industrial-grade standard, anti-interference design for harsh electromagnetic environment

◆ 32 bit RISC (NP7 series) ARM7TDMI 55DMIPS

◆ 128KB SRAM,128KB Code + 32KB Boot

◆10M/100M adaptive Ethernet interface

◆Support RS422/RS485 data bits 5,6,7,8 settable

◆Support RS422/RS485 stop bit 1,1.5,2 settable
◆Support RS422/RS485 parity NONE, ODD, EVEN, MARK, SPACE settable
◆Support RS422/RS485 baud rate 110 ~ 115200bps standard rate settable
◆Support the RS422/RS485 communications which meet UART serial data communication standard, do not support field bus protocol.
◆Smart protocols: TCP, UDP, ARP, IP, ICMP, DHCP, BOOTP, DNS

◆Support dynamic DNS
◆Working mode can be TCP Server, TCP Client, UDP multicast and unicast UDP

◆Built-in Flash memory, can save the setted parameters
◆Support Windows 95/98/ME/NT/2000/XP/2003/XP/Win7 operating system, Vista is not recommended
◆RJ45 port 1500VDC electromagnetic isolated,RS422 interface 1500VDC electromagnetic isolated,
◆Interface protection: power supply port has the reverse polarity protection and over current protection, RS422 interface has the surge protection ;all pins and terminals have anti-static protection.
◆5V±10% DC power supply from FX series PLC RS422 socket,1W power
◆Dimension: L × W × H = 65mm × 51mm × 26mm, 35mm Standard rail mounting
◆Operating Temperature: -40 ° C to +80 ° C (-40 ° F to 176 ° F), 5% to 95% RH (industrial grade)
◆Storage Temperature: -40 ° C to +80 ° C (-40 ° F to 176 ° F), 5% to 95% RH

Only need USD150.00, you can get 1 piece of ES-ETH-SC09.

Buy now =====> buy buttom

Product Content:  
1.ES-ETH-SC09  1PC
2. RJ45 Cable 1 PC,2 M
3.CD 1PC

 

Please feel free to contact me if you have any question.

 

May 10 2013

OP programming cable: replace 6XV1 440-2KH32

OP programming cable: replace 6XV1 440-2KH32

 

6XV1440-2KH32   CONNECTION CABLE BETWEEN TD/OP
CONNECTION CABLE BETWEEN TD/OP (RS232 / SOCKET 15 WAY) AND – SIMATIC 505 PLC 545, 555 – ALLEN BRADLEY SLC500/03,04 -PC (RS232 / 9 PIN PLUGS) STANDARD LENGTH 3,2 M
Our company have the compatible cable, named OP programming cable,  can replace Siemens 6XV1 440-2KH32.You can have a look on the picture.
OP Programming Cable-small 

You can get it only need USD18.00/pc.    Buy now ====>  buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

 

Please feel free to contact me if you have any question.

 

 

May 10 2013

MPI cable:Cable between S7-200/300 PLC and Siemens touch panel, 6ES7901-0BF00-0AA0.

MPI cable:Cable between S7-200/300 PLC and Siemens touch panel, 6ES7901-0BF00-0AA0.

6ES7901-0BF00-0AA0                      S7 MPI CABLE, 5M
SIMATIC S7, MPI CABLE FOR CONNECTING SIMATIC S7 AND PG VIA MPI 5M
Below is the data sheet of Siemens original 6ES7901-0BF00-0AA0:
Field PG M3 accessories

-

SIMATIC S7, MPI CABLE FOR CONNECTING SIMATIC S7 AND PG VIA MPI 5M
Cables
belongs to product MPI
Cable length 5 m
Weight
Weight, approx. 293 g
Our company have the compatible cable, named MPI cable,  can replace Siemens 6ES7901-0BF00-0AA0.

Communication cable between S7-200/300 PLC and Siemens touch panel,5 meters,correspond to Siemens 6ES7 901-0BF00-0AA0.

CP5611,CP5512 need this cable to connect PLC.

The quality is guaranteed.It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

You can have a look on the picture.
MPI cable-small
You can get it only need USD18.00/pc.    Buy now ====> buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

For any question, pls feel free to contact me.
May 9 2013

LOGO!USB-CABLE:USB isolated adapter for Siemens LOGO! Replace Siemens 6ED1057-1AA01-0BA0.

LOGO!USB-CABLE:USB isolated adapter for Siemens LOGO!
Can replace Siemens original 6ED1057-1AA01-0BA0.

 

6ED1057-1AA01-0BA0     LOGO! USB PC-CABLE F. PROGRAM TRANSMITT.
LOGO! USB PC CABLE FOR PROGRAM TRANSMITTING FROM PC TO LOGO! AND VICE VERSA DRIVER ON CD-ROM INCLUDED
Our company have the compatible cable, named LOGO!USB-CABLE,  can replace Siemens 6ED1057-1AA01-0BA0.
You can have a look on the picture.
logo!USB-Cable-small

You can get it only need USD45.00/pc.    Buy now ====>  buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Here, below is the descriptions of our compatible LOGO!USB-CABLE:

USB optoelectronic isolated cable for Siemens LOGO!,2.5 meters,with communication indicator.

LOGO! USB-CABLE is a programming cable which use the USB interface to achieve the serial connection and the conversion of peripheral port signal. Under the control of computer operation,simulating the computer’s USB interface to traditional serial(commonly known as COM port),thus using the current programming software,communicating software and monitoring software.The work power of the cable comes from USB port and programming port of LOGO! controller.

USB-CABLE is photoelectric isolated,can be applied to LOGO! Controller,especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give permission to the safe operation of the system.

LOGO!USB-CABLE’ s chart appearance:

Characteristics and specifications:

● Support USB-CABLE programming software version:LOGO! Soft V4.0 and above
● Fully compatible with standard USB V2.0
● Power supplied by USB bus and the programming port of LOGO! Controller.
● Optical isolation voltage:1000VDC
● Support UART data format:Data:7、8,stop bit:1、2,check:odd/even/no parity
● Each PC only supports one USB cable
● Working temperature:-20~+75℃
● Cable length:2.5m,color:black

System requirement
Please make sure your PC is IBM PC compatible and has the following system requirements before using the USB programming cable.
● Intel is compatible with 586DX4-100MHz CPU or higher
● A standard USB port (4-pin A plug)
● Operating system is Windows2000 or Windows XP
Setting of LOGO!Soft-Comfort
After completing the driver installation,In the Windows Device Manager will come up the COM port of USB-CABLE programming cable,just in the programming of software or other software applications,selecting the COM port.And the follow applyment is exactly the same as the traditional RS232 programmng cable.
Open the main windows form(LOGO!Soft-Comfort),choose “Tools” menu then click “Options…” sub menu and will appear Options setting window.
Select “Interface” Item in the left list,and Choose the COMX interface as it in the Device Manager.

Applications:
USB-CABLE programming cable can only be used under the device of USB. After completing the driver installation,In the Windows Device Manager will come up the COM port of USB-CABLE programming cable,just in the programming of software or other software applications,selecting the COM port.And the follow applyment is exactly the same as the traditional programming cable.

Note: The maximum extension of the USB cable could reach 5 meters.

The quality is guaranteed.It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

 

For any question, please feel free to contact me.

 

May 9 2013

LOGO!PC-CABLE:RS232 isolated cable for Siemens LOGO! 6ED1 057-1AA00-0BA0

LOGO!PC-CABLE:RS232 isolated cable for Siemens LOGO! 6ED1 057-1AA00-0BA0

 

6ED1057-1AA00-0BA0        LOGO! PC CABLE
LOGO! PC CABLE, F. THE TRANSMISSION OF PROGRAMS FROM PC TO LOGO! AND VICE VERSA
Here, below data sheet of Simens orignal 6ED1057-1AA00-0BA0:
LOGO! RS232 PC cable

-

LOGO! PC CABLE, F. THE TRANSMISSION OF PROGRAMS FROM PC TO LOGO! AND VICE VERSA
Cables
belongs to product LOGO!
Cable length 3 m
Weight
Weight, approx. 168 g
Our company have the compatible cable, named LOGO!PC-CABLE,  can replace Siemens 6ED1 057-1AA00-0BA0.
You can have a look on the picture.
logo!pc-cable-small
Now, only need USD43.00, you can get it.  Buy now  =======> buy buttom
It’s tested before shippment.Not made by Siemens,OEM product as the replacement.
The quality is guaranteed, we have 1 year warranty for our compatible products.
Below is the decription of   LOGO!PC-CABLE :
RS232 optoelectronic isolated programming cable for Siemens LOGO!,3 meters,can replace Siemens 6ED1 057-1AA00-0BA0The quality is guaranteed.It’s tested before shippment.Not made by Siemens,OEM product as the replacement.
May 8 2013

PC/MPI: RS232 Programming adapter for Siemens S7-300 PLC can replace Siemens 6ES7972-0CA23-0XA0

PC/MPI: RS232 Programming adapter for Siemens S7-300 PLC  can replace Siemens 6ES7972-0CA23-0XA0

6ES7972-0CA23-0XA0                     PC-ADAPTER V5.1, RS 232/RS485 CONVERSION
SIMATIC S7, PC ADAPTER V5.1 FOR CONNECTION OF S7-300/400, C7, M7; FOR CONVERSION OF RS232 TO RS485; W/O RS232 CABLE
Below is the data sheet of Siemens  6ES7972-0CA23-0XA0:
SIMATIC S7, PC ADAPTER V5.1 FOR CONNECTION OF S7-300/400, C7, M7; FOR CONVERSION OF RS232 TO RS485; W/O RS232 CABLE
Supply voltage
5 V DC Yes; UN2
24 V DC Yes; UN1
Input current
Current consumption, typ. 90 mA; I1: 50 mA, I2: 40 mA
Inrush current, max. 0.5 A; I1: 0.5 A, 14 ms; I2: 0.2 A, 1.5 ms
1st interface
Type of interface RS 485 (up to max. 1.5 Mbit/s)
2nd interface
Type of interface RS 232 (19.2 kbit/s or 38.4 kbit/s, adjustable by switch)
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes; +/-4 kV contact discharge (to IEC 801-2/IEC 1000-4-2; ESD) +/-8 kV air discharge (to IEC 801-2/IEC 1000-4-2; ESD)
Interference immunity to cable-borne interference
Interference immunity on signal lines acc. to IEC 61000-4-4 Yes; +/- 2 kV (to IEC 801-4/IEC 1000-4-4; Burst)
Immunity against high-frequency electromagnetic fields
Interference immunity against high frequency radiation 10 V/m with 80% amplitude modulation at 1 kHz, 10 kHz to 80 MHz (to ENV 50141); 10 V/m with 80% amplitude modulation at 1 kHz, 80 MHz to 1 GHz (to ENV 50140); 10 V/m pulse modulated 50% ED at 900 MHz (to ENV 50204)
Emission of radio interference acc. to EN 55 022
Interference emission acc. to EN 55022, class B Yes; corresponds to CISPR 22
Degree and class of protection
IP20 Yes
Ambient conditions
Operating temperature
Min. 0 °C
max. 60 °C
Permissible temperature change 10 °C/h; Operation: max. 10°C/h; storage/transport: max. 20°C/h
Storage/transport temperature
Min. -40 °C
max. 70 °C
Relative humidity
Operation, min. 5 %
Operation, max. 85 %; no condensation
Storage/transport, min. 5 %
Storage/transport, max. 93 %; no condensation
Vibrations
Operation, checked according to IEC 60068-2-6 Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 150 Hz: Acceleration 9.8 m/s2
Transport tested checked to IEC 60068-2-6 Yes; (packed) 5 to 9 Hz, amplitude 3.5 mm; 9 to 500 Hz, acceleration 9.8 m/s2
Shock test
checked according to IEC 60068-2-27 Yes; Operation: Half-sine: 100 m/s2 (10 g), 16 ms, transport (packed): Half-sine: 250 m/s2 (25 g), 6 ms
checked according to IEC 60068-2-29 Yes
Dimensions
Width 50 mm
Height 24 mm
Depth 108 mm
Weight
Weight, approx. 150 g
Our company have the compatible cable, named PC/MPI,  can replace Siemens 6ES7972-0CA23-0XA0.
Here, pls have a look on its picture:
PC-MPI
Now, only need USD71.00, you can get it.     Buy now ====> buy buttom
It’s tested before shippment.Not made by Siemens,OEM product as the replacement.The quality is guaranteed, we have 1 year warranty for our compatible products.

The discription of our compatible PC/MPI:

Siemens S7-300 PLC Programming cable,5 meters.

Not isolated,so it doesn’t support hot plug.

PC / MPI adapter is also known as PC adapter. It’s physical interface is the conversion from RS232 interfaces to the RS485,including the conversion from RS232 to MPI protocol (MultiPoint Interface).And it is used for the connecting between the PC COM (RS232) and MPI (RS485) of Siemens S7-300PLC.This product is non-isolate, choose PC / MPI + if you need an electro-optical isolation.

Main technical parameters:

★ RS232 Port baud rate:19.2Kbps

★ MPI Port baud rate:187.5Kbps

★ With the data received and sent indicator light

★ Temperature:0~75℃

★ Total length of cable:5m

STEP7 Software settings:

1、 Go into STEP7 the main software programming interface(SIMATIC Manager),click “Set PG/PC Interface…” which is under the “Options” menu, and the get to the PG/PC setting interface。

2、 Double-click on “PC Adapter(Auto)”or“PC Adapter(MPI)”to go into the interface setting of parameters of RS232 and the MPI. The adapter does not support “PC Adapter (PROFIBUS)” option.

3、 Click on the “Local Connection” option to set the interface parameters of RS232, to choose the right computers COM mouth (RS232), change the RS232 communication baud rate to 19200 bps.

4、 Click the “MPI” option (if it’s on “PC Adapter (MPI)” method) to set MPI interface parameters for the adapter, as the MPI interface of the adapter gets the baud rate fixed at 187.5 Kbps, so here can only be set to 187.5 Kbps.
If it is “PC Adapter (Auto)” method the choice should be “Address: 0″ and “Timeout: 30s”.

After the settings above the adapter can be set up on-line communication with the PLC, now you should pay attention to that you shouldn’t change the factory default of the MPI port baud rate 187.5Kpbs on the CPU which is under the “Network Settings”.

Since the baud rate of the MPI port of the adapter is fixed at 187.5Kbps, if it is set at other figures, the adapter will not work with PLC! Make sure that the baud rate of the MPI port on your S7-300PLC’s CPU is fixed at 187.5Kpbs.Otherwise,you have to use the Siemens’s programming communication facility to set that baud rate to 187.5Kpbs,in order to make the adapter work correctly.
The quality is guaranteed.It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

 

Please feel free to contact me if you have any question.

 

May 8 2013

PC/MPI+: RS232 isolated Programming adapte for Siemens S7-300/400 PLC,6ES7972-0CA23-0XA0

 

PC/MPI+:  RS232 isolated Programming adapte for Siemens S7-300/400 PLC,6ES7972-0CA23-0XA0

 

6ES7972-0CA23-0XA0                        PC-ADAPTER V5.1, RS 232/RS485 CONVERSION

SIMATIC S7, PC ADAPTER V5.1 FOR CONNECTION OF S7-300/400, C7, M7; FOR CONVERSION OF RS232 TO RS485; W/O RS232 CABLE

SIMATIC S7, PC ADAPTER V5.1 FOR CONNECTION OF S7-300/400, C7, M7; FOR CONVERSION OF RS232 TO RS485; W/O RS232 CABLE
Supply voltage
5 V DC Yes; UN2
24 V DC Yes; UN1
Input current
Current consumption, typ. 90 mA; I1: 50 mA, I2: 40 mA
Inrush current, max. 0.5 A; I1: 0.5 A, 14 ms; I2: 0.2 A, 1.5 ms
1st interface
Type of interface RS 485 (up to max. 1.5 Mbit/s)
2nd interface
Type of interface RS 232 (19.2 kbit/s or 38.4 kbit/s, adjustable by switch)
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes; +/-4 kV contact discharge (to IEC 801-2/IEC 1000-4-2; ESD) +/-8 kV air discharge (to IEC 801-2/IEC 1000-4-2; ESD)
Interference immunity to cable-borne interference
Interference immunity on signal lines acc. to IEC 61000-4-4 Yes; +/- 2 kV (to IEC 801-4/IEC 1000-4-4; Burst)
Immunity against high-frequency electromagnetic fields
Interference immunity against high frequency radiation 10 V/m with 80% amplitude modulation at 1 kHz, 10 kHz to 80 MHz (to ENV 50141); 10 V/m with 80% amplitude modulation at 1 kHz, 80 MHz to 1 GHz (to ENV 50140); 10 V/m pulse modulated 50% ED at 900 MHz (to ENV 50204)
Emission of radio interference acc. to EN 55 022
Interference emission acc. to EN 55022, class B Yes; corresponds to CISPR 22
Degree and class of protection
IP20 Yes
Ambient conditions
Operating temperature
Min. 0 °C
max. 60 °C
Permissible temperature change 10 °C/h; Operation: max. 10°C/h; storage/transport: max. 20°C/h
Storage/transport temperature
Min. -40 °C
max. 70 °C
Relative humidity
Operation, min. 5 %
Operation, max. 85 %; no condensation
Storage/transport, min. 5 %
Storage/transport, max. 93 %; no condensation
Vibrations
Operation, checked according to IEC 60068-2-6 Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 150 Hz: Acceleration 9.8 m/s2
Transport tested checked to IEC 60068-2-6 Yes; (packed) 5 to 9 Hz, amplitude 3.5 mm; 9 to 500 Hz, acceleration 9.8 m/s2
Shock test
checked according to IEC 60068-2-27 Yes; Operation: Half-sine: 100 m/s2 (10 g), 16 ms, transport (packed): Half-sine: 250 m/s2 (25 g), 6 ms
checked according to IEC 60068-2-29 Yes
Dimensions
Width 50 mm
Height 24 mm
Depth 108 mm
Weight
Weight, approx. 150 g

 

Our company have the compatible cable, named PC/MPI+,including RS232 cable,  can replace Siemens original 6ES7972-0CA23-0XA0.

Please look at below picture of our compatible PC/MPI+ including RS232 cable :

PC-MPI+

You can get it only need USD90.00/pc.    Buy now ====>  buy buttom

When you buy PC/MPI+,we will give you the free RS232 Cable.

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

 

Description of our compatible PC/MP+  :

Optoelectronic isolated RS232/MPI,Siemens S7-300/400 PLC Programming adapter cable,with communication indicator,can replace Siemens 6ES7 972-0CA23-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.Can connect PLC and the touch panel of third party factory to communicate.It doesn’t support profibus function.

PC/MPI+ adapter, or named PC adapter, could achieve the level conversion of RS232 to RS485 and the protocal conversion of RS232 to MPI(MultiPoint Interface).PC/MPI+ is the adapter of photoelectric isolation type towards industrial design. Between RS232 port and RS485 port exist the surge protection and anti-lightning protection circuit, adaptable to the full PLC series of Siemens S7-300/400 and those devices with MPI port, especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give promission to the safe operation of the system.

PC/MPI+ can make touch-screen communications with the third party under the link of S7-300/400PLC, such as eView, Wei-lun and kun-lun state.

Characteristics and main technical parametres:

★ Power: It is supplied by the 24VDC MPI port of PLC, power consumption of about 1w, with overcurrent protection and surge protection.
★ Isolation Voltage: 1000VDC(Maximun to 3000 VDC, orders require statement.)
★ RS232 port has anti-surge protection, RS485 port has anti-lightning protection and overcurrent protection with the consumption of 500w.
★ RS232 port baud rate: 19.2Kbps—115.2Kbps, automatically adaptable to the standard baud rate.
★ MPI port baud rate: 187.5Kbps—19.2Kbps, automatically adaptable.
★ Supporting the connection of PLC to touch-screen communication with the third party.
★ With a power indicater light, on-line and data transmission indicater light.
★ Working temperature: -20~75′C
★ Dimension: 103×50×26; After connecting the RS232 cables: 5.5m.

RS232 adapter port and port-pin RS485 signal definations:

 

Pin number

Signal name

Instructions

Pin number

Signal name

Instructions

1

DCD

No use

1

NC

No use

2

RXD

RS232 signal reception

2

M24V

Negtive 24VDC power

3

TXD

RS232 signal sending

3

B

RS485 positive signal

4

DTR

Short circuit with No.6

4

RTSAS

Data reception control

5

GND

RS232 signal to ground

5

GND

RS485 signal to ground

6

DSR

Short cut with No.4

6

NC

No use

7

RTS

Sending requsts

7

P24V

24VDC positive power

8

CTS

Sending clear

8

A

RS485 negtive signal

9

RI

No use

9

RTS_PG

Data-send control

 RS232-Block(DB9M) defination signals RS485-Block(DB9M) defination signals

 

Indicater light

On

Qlittering

Out

Power

Normal

Error

Error or failing to link to power

Active

Online

Transmission of data

Not online

Tx

Error

Send data

No data transmission

 Instructions of the indicater light

Software settings of STEP7:
Entering the main interface of STEP7 programming software(SIMATIC Manager), clicking on “Options” menu under the “Set PG/PC Interface…” option into the PG/PC interface settings.
1. Double clicking on “PC Adapter(MPI)” into the RS232 interfaces and MPI set of parameters. The adapter does not support “PC Adapter(PROFIBUS)” option.
2. Clicking on “Local Connection” option set RS232 interface parameters, choosing PC/MPI to connect on the port of COM correctly, and it will adapt to the chosen baud rate automatically, both 19200bps and 38400bps of RS232 communication.
3. Clicking “MPI” to set port parameters of adapter MPI, acceptable at both 187.5Kbps and 19.2Kbps, and the adapter will adapt to its baud rate automatically. Others have already been set.
4. On-line test accessing point: Using PC/MPI to connect to MPI port and RS232 port of the computer. And then click on the button in the red circle as follow, if appearing the data inside the red line, the test has passed. Then one could operate on it.

 

The long-distance communication of PC/MPI+ adapter:

1. To extend the distance of RS485 port:

2. To extend the distance of RS232 port:

RS232 Cable:

When you buy PC/MPI+,we will give you the free RS232 Cable.

The quality is guaranteed.It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

 

 

May 8 2013

PC/PPI+:RS232 to PPI optoelectronic isolated adapter for Siemens S7-200 PLC,replace 6ES7 901-3CB30-0XA0

PC/PPI+:  RS232 to PPI optoelectronic isolated adapter for Siemens S7-200 PLC,replace 6ES7 901-3CB300-0XA06ES7 901-3CB30-0XA0SIMATIC S7-200, PC/PPI CABLE MM MULTIMASTER, FOR CONNECTING S7-200 TO SERIAL PORT OF PC, SUPPORTS FREEPORT AND GSM MODEMS 
Please find below data sheet of Siemens original 6ES7 901-3CB30-0XA0.

SIMATIC S7-200, PC/PPI CABLE MM MULTIMASTER, FOR CONNECTING S7-200 TO SERIAL PORT OF PC, SUPPORTS FREEPORT AND GSM MODEMS
Cables
belongs to product SIMATIC S7-200
Interfaces
Point-to-point
Transmission rate (PPI), max. 187.5 kbit/s; 9.6 / 19.3 / 187.5 kbit/s; setting: DIP switch; RS232 not required
Protocols
PPI Yes; 10/11 bit
ASCII Yes; Freeport
Interrupts/diagnostics/status information
Diagnostics indication LED
Description Tx (green): RS-232-transmit indication; Rx (Grün): RS-232-receive indication; PPI (Green): RS-485-transmit indication
Galvanic isolation
Galvanic isolation 1
Software requirement
Software required STEP 7 Micro/WIN V3.2 SP4 or higher
Weight
Weight, approx. 300 g
Status Mar 11, 2013

Our company have the compatible cable, named PC/PPI+,  can replace Siemens 6ES7 901-3CB30-0XA0.

You can have a look on the picture.

PC-PPI+

You can get it only need USD48.00/pc.    Buy now ====>  buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products

 

Optoelectronic isolated PC/PPI cable,support 10 bit and 11 bit modem communication,with communication indicator,automatically adjust the baud rate from 0 to 115.2Kbps,the largest communication distance of up to 2 kilometers.Not support multi-master station communication.

Specifications:

The OEM Siemens S7-200 PC-PPI+ Programming cable supports full range of Siemens S7-200 PLC programming. It is 100% good replacement for the expensive Simens cable.. It’s tested and proven on S7-212, S7-211, S7-214, S7-224, S7-224XP and it works as a standard Simens serial PC/PPI+ port.

The PC/PPI+ programming cable is the transformation electric cable from RS232 to the PPI connection (RS485), and it is suitable for Simens S7-200 series PLC and the TP170 touchscreen programming, the correspondence and the monitoring. It also supports the PPI agreement and the free mouth communication protocol, and can use MODEM (modem) through the telephone line to make a long-distance correspondence. Since the cable is isolated with the electro-optical and built-in anti-static, surge and other transient over-voltage protection circuit, it solves the problem that the communication I always burned easily well. And it is especially suitable for the long-term monitoring communications which are under the industrial site with a poor environment.

Main technical parameters:

★ Isolation voltage: 1000VDC(The maximum to 3000 VDC, orders required statement)
★ According to a transient voltage suppression. The RS485 port can withstand the power of up to 500 W transient over-voltage and lightning impact,the RS232 port and power circuit are equipped with surge protection to protect the circuit. The whole product can be arbitrarily charged plug.
★ Baud rate:0~115.2kbps Adaptive(products available for sale since January 2008 )
★ The longest communication distance:2 km(Baud rate:9600bps per hour),1km(Baud rate:115.2Kbps per hour)
★ With a power indicator light and the data received and sent indicator light
★ Temperature:-40~85′C(products available for sale since January 2008)
★ Dimension:103×50×26,The total length of cable is 5m.

The product structure:

PPI-RS485 plug

PC-RS232 plug

Pin

Signal explanation

Pin

Signal explanation

2

24V Power source negative(RS485 Logical place)

2

Receive data RD(Output from PC/PPI)

3

RS485 signal B(RxD/TxD+)

3

Send data SD(Send to PC/PPI)

7

24V Power source positive

4

Data terminal ready DTR

8

RS485 signal A(RxD/TxD-)

5

Ground(RS232 Logical place)

9

Agreement choice

7

Require to send RTS

Signals of PC-RS232 plugs and PPI-RS485 plugs

The use of products:
1, PLC and computer connections for the PPI or free Communication, programming:
Insert the PC / PPI + cable’s RS485 plug into the programming mouth of S7-200PLC and the RS232 plug into the computer’s RS232 port. Chose the corresponding number of the COM port. Switch the 10bit, 11bit selection switch to 11 bit. The baud rate of the PC/PPI+ cable is adaptive from 0 to 115.2kpbs. There is no need to set that.
2, The long-distance communications between PLC and computer:
When having long-distance communications, the PC / PPI + requires additional external power and we should parallel 120Ωi end resistance n between the 3, 8 of RS485 plugs to eliminate signal reflection, as shown below:
3, long-distance communications between the PLC and computer via telephone lines:
You have to make a cross-adapter by yourself when you get the PC/PPI+’s RS232 port and the MODEM connected. Switch to the corresponding location according to the MODEM that it is 10 or 11.
10 bits MODEM refers: 1 outset bit, 8 data bits, no parity bit, and 1 stop bit(or 7 data bits,1 parity bit).This kind of MODEM is comparative common on the market.
11 bits MODEM refers: 1 outset bit, 8 data bits, 1 parity bit (Occasionally bit check), and 1 stop bit .

 

If you need non- isolated cable,you can choose our PC/PPI,you can click the following website for PC/PPI:PC-PPI.

PC-PPI

Only need USD19.00/pc, you can get it.     Buy now ====>buy buttom

 

We also provide other Compatible Accessories for Siemens PLC series, please contact us to buy it!

 

Accessories of Replacements

Orignal Siemens Model

Profibus BUS Connector(90  without Program interface)

6ES7972-0BA12-0XA0

Profibus BUS Connector(90 with Program interface)

6ES7972-0BB12-0XA0

Profibus BUS Connector(35 without Program interface)

6ES7972-0BA41-0XA0

Profibus BUS Connector(35 with Program interface)

6ES7972-0BB41-0XA0

Profibus BUS Connector

6ES7 972-0BA50-0XA0

Profibus BUS Connector

6ES7 972-0BB50-0XA0

Profibus BUS Connector

6ES7 972-0BA52-0XA0

Profibus BUS Connector

6GK1500-0FC10

Profibus BUS Connector

6ES7 972-0BB52-0XA0

Profibus BUS Connector

6GK1 500-0EA02

Profibus BUS Connector

6GK1 500-0FC00

Profibus BUS Cable

6XV1 830-0EH10  

Profibus BUS Cable

6XV1830-3EH10   

Profibus BUS Cable

6XV1840-2AH10   

20-Pin front Connector

6ES7392-1AJ00-0AA0

40-Pin front Connector

6ES7392-1AM00-0AA0

CP5611 Card

6GK1561-1AA00

CP5611 Card

6GK1561-1AA01

PLC Li-on Battery

6ES7291-8BA20-OXAO

PS307 Power supply 5A

6ES7307-1EA00-0AA0

PS307 Power supply 10A

6ES7307-1KA01-0AA0

PS307 Power supply 10A

6ES7307-1KA02-0AA0

DIN Track(830mm)

6ES7390-1AJ30-0AA0

DIN Track(530mm)

6ES7390-1AF30-0AA0

DIN Track(480mm)

6ES7390-1AE80-0AA0

Hot-Plug Track(530mm)

6ES7390-1GF30-0AA0