6ES7332-5HD01-0AB0 Siemens Analog output module

Introduction to Siemens 6ES7332-5HD01-0AB0

SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 4 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 20 PIN, REMOVE/INSERT W. ACTIVE, BACKPLANE BUS

 

Properties of Siemens 6ES7332-5HD01-0AB0
● 4 outputs in one group
● The output can be selected by individual channel
– Voltage output
– Current output
● Resolution 12 bits
● Programmable diagnostics and diagnostic interrupt
● Electrically isolated to backplane bus interface and load voltage
● Supports parameter reassignment in RUN
Diagnostics
For information on diagnostic messages at the "group diagnostics" parameter, refer to
chapter Diagnostic messages of analog output modules (Page 310).
Terminal assignment
The diagrams below show various wiring options.
Note
When you switch the rated load voltage (L+) off and on, the outputs can return incorrect
voltage/current values for the duration of about 500 ms.

 

Wiring: 2 and 4-wire connection for voltage output
The following Fig. represents the 2-wire connection with no compensation for line resistors
and the 4-wire connection with compensation for line resistors.

8

Wiring: Current output

9

 

Technical specifications of 6ES7332-5HD01-0AB0

     2
   
SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 4 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 20 PIN, REMOVE/INSERT W. ACTIVE, BACKPLANE BUS
 
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Input current
from load voltage L+ (without load), max. 240 mA
from backplane bus 5 V DC, max. 60 mA
Power losses
Power loss, typ. 3 W
Analog outputs
Number of analog outputs 4
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, max. 25 mA
Current output, no-load voltage, max. 18 V
Output ranges, voltage
0 to 10 V Yes
1 to 5 V Yes
-10 to +10 V Yes
Output ranges, current
0 to 20 mA Yes
-20 to +20 mA Yes
4 to 20 mA Yes
Load impedance (in rated range of output)
with voltage outputs, min. 1 kΩ
with voltage outputs, capacitive load, max. 1 µF
with current outputs, max. 500 Ω
with current outputs, inductive load, max. 10 mH
Cable length
Cable length, shielded, max. 200 m
Analog value creation
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 12 bit; +/-10 V, +/-20 mA, 4 to 20 mA, 1 to 5 V: 11 bits + sign; 0 to 10 V, 0 to 20 mA: 12 bits
Conversion time (per channel) 0.8 ms
Settling time
for resistive load 0.2 ms
for capacitive load 3.3 ms
for inductive load 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to output area +/- 0,5 %
Current, relative to output area +/- 0,6 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to output area +/- 0,4 %
Current, relative to output area +/- 0,5 %
Interrupts/diagnostics/status information
Substitute values connectable Yes; Parameterizable
Alarms
Diagnostic alarm Yes; Parameterizable
Diagnostic messages
Diagnostic information readable Yes
Diagnostics Yes
Diagnostics indication LED
Group error SF (red) Yes
Galvanic isolation
Galvanic isolation analog outputs
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 220 g

 

Parameter reassignment in RUN
If you reassign parameters in RUN, the following special characteristic applies.
SF LED is lit:
If a diagnostics was pending prior to reconfiguration, the SF LEDs (on CPU, IM or module)
may be lit even though diagnostics is no longer pending and the module is operating correctly.
Solution:
● Only assign new parameters if no diagnostics is pending, or
● unplug module and plug it in again.

 

Output ranges of SM 332; AO 4 x 12 Bit
Introduction
You can configure the outputs for operation as voltage or current outputs, or disable them.
You program the outputs at the "output type" parameter in STEP 7.
The output type "Voltage" and output range "± 10 V" are set by default at the module. You
can always use this combination of output type and range without having to program the
SM 332; AO 4 x 12 Bit in STEP 7.
Output ranges
Program the voltage and current output ranges in STEP 7.
Output ranges of SM 332; AO 4 x 12 Bit

 Selected type of output    Output range  
 Voltage    1 V to 5 V 0 V to 10 V  
   ± 10 V  
 Current    0 mA to 20 mA  
   4 mA to 20 mA  
   ± 20 mA  

 

Overview of the parameters of SM 332; AO 4 x 12 Bit

10

 

Assigning parameters to channels
The parameters can be set separately at each output channel of SM 332; AO 4 x 12 Bit. You can assign separate parameters to each output channel.
Assign the parameters you set at the SFCs in the user program to the channel groups. Each output channel of SM 332; AO 4 x 12 Bit is thus assigned to a channel group, i.e. output channel 0 > channel group 0, for example.


Note
The output may carry incorrect interim values if you modify output ranges while SM 332;AO 4 x 12 Bit is in RUN.

Additional information on SM 332; AO 4 x 12 Bit

Unused channels
To take unused output channels of SM 332; AO 4 x 12 Bit off power, set the "disabled" argument at the "output type" parameter. Disabled channels do not have to be wired.
Line continuity check
SM 332; AO 4 x 12 Bit only performs a line continuity check at the current outputs.In output ranges 0 mA to 20mA and ±20 mA, a "reliable" wire-break check is not possible for output values of-20s to ±200 μA.
Short-circuit test
SM 332; AO 4 x 12 Bit only performs a short-circuit test at the voltage outputs.
Substitute values
You can configure the SM 332; AO 4 x 12 Bit for CPU STOP mode as follows: Outputs off power, hold last value or set substitute values. The set substitute values must lie within the output range.

 

 

USER'S manual PDF of 332-5HD01, please refer from Page 481- Page 489:

 

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7332-5HD01-0AB0,

it is 100% compatible with Siemens original part.


Part#: 6ES7332-5HD01-0AB0

Unit price:USD310.00/pc     buy buttom

Description: S7-300 Analog onput module
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China


Here, you also need 1 piece of 20pin front connector to connect with it.

Our compatible 6ES7 392-1AJ00-0AA0 can meet your requirements.

 

6ES7 392-1AJ00-0AA0  @USD10.50/pc   buy buttom

 

Technical data sheet of our SM 332  6ES7332-5HD01-0AB0

Model

SM332

4AO

Product  Description

4AO;

 Resolution:12bits; High-accuracy

Power consumption

·From bus current consumption

40mA

·From L+

40mA

·Power loss

3W

Number of analog outputs

4

Load voltage+rated value

24V

Shielded cable length,Max

200m

Voltage output,

Max,short circuit Current

Yes

Voltage output,

Short circuit current(Max)

25mA

Voltage output,

Open-circuit current,Max

18V

Load impedance

·Voltage outputs,Min

1KΩ

·current outputs,Max

500Ω

Output ranges

·voltage

±10V,0~10V,1~5V

·current

±20mA,0~20mA,4~20mA

D/A resolution

12bit

conversion time(per channel)

Max:0.8ms

Setting time

 

·Resistive loads

0.1ms

·Capacitive loads

3.3ms

·Inductive loads

0.5ms

Output cross talk

>40dB

Tolerance(Over entire temperature range)

·Voltage output

±0.5%

·Current output

±0.6%

Diagnostic interrupt

None

Group fault error

Red LED

Isolution tested for contact

 

·Between channels and backplane bus

Yes

·Between channels and load voltage L+

Yes

Front connector

20-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

 332-5HD01-0AB0

 

Picture of 6ES7332-5HD01-0AB0

332-5HD01-0AB0

 

More compatible Siemens S7-200/300 modules we can offer:

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

S7-300 322-1BH02 322-1BL00 S7-200 321-1BL00 331-1KF01 product 3311kf01 3311kf01-00

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 6 2013

6ES7331-1KF01-0AB0 Siemens Analog input module

Introduction to 6ES7331-1KF02-0AB0

 

SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, PTC / KTY, 66 MS MODULE UPDATE, 1 X 40 PIN


Properties of 6ES7331-1KF02-0AB0
● 8 inputs in 8 channel groups
● Programmable resolution at each channel group (12 bits + sign)
● Programmable measurement type per channel group:
– Voltage
– Current
– Resistance
– Temperature
● Any measuring range per channel
● Motor protection / temperature monitoring with PTC in accordance with IEC 60034-11-2
type A
● Temperatures recorded via KTY83/110, KTY84/130 silicon temperature sensors
Terminal assignment
The diagrams below show various wiring options. These examples apply to all channels
(channel 0 to 7).


Note
When connecting voltage and current transducers, make sure that the maximum permitted
common-mode voltage CMV of 2 V is not exceeded between the inputs. Prevent measuring
errors by interconnecting the corresponding M- terminals.

Wiring: Voltage measurement


When connecting voltage and current transducers, make sure that the maximum permitted
common-mode voltage CMV of 2 V is not exceeded between the inputs. Prevent measuring
errors by interconnecting the corresponding M- terminals.

 

Wiring: Voltage measurement

 

1

 

Wiring: 2-wire and 4-wire transducers for current measurement

2

 

Wiring: Resistance measurement with 2-, 3- and 4-wire connection
The following connection possibilities also apply to silicon temperature sensors and PTCs.

3

 

Note
It is not necessary to interconnect the M- terminals when measuring using resistors,
resistance thermometers, PTCs, or silicon temperature sensors. However, interconnection of
the M- terminals may enhance interference immunity.

 

Technical specifications of Analog input module 6ES7331-1KF02-0AB0

       1

SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, PTC / KTY, 66 MS MODULE UPDATE, 1 X 40 PIN
 
Input current
from backplane bus 5 V DC, max. 90 mA
Power losses
Power loss, typ. 0.4 W
Analog inputs
Number of analog inputs 8
Number of analog inputs for resistance measurement 8
permissible input voltage for voltage input (destruction limit), max. 30 V; 12 V continuous, 30 V for max. 1 s
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
Voltage Yes
Current Yes
Thermocouple No
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), voltages
0 to +10 V Yes
Input resistance (0 to 10 V) 100 kΩ
1 to 5 V Yes
Input resistance (1 to 5 V) 100 kΩ
1 to 10 V No
-1 V to +1 V Yes
Input resistance (-1 V to +1 V) 100 kΩ
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) 100 kΩ
-2.5 V to +2.5 V No
-250 mV to +250 mV No
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) 100 kΩ
-50 mV to +50 mV Yes
Input resistance (-50 mV to +50 mV) 100 kΩ
-500 mV to +500 mV Yes
Input resistance (-500 mV to +500 mV) 100 kΩ
-80 mV to +80 mV No
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 100 Ω
-10 to +10 mA No
-20 to +20 mA Yes
Input resistance (-20 to +20 mA) 100 Ω
-3.2 to +3.2 mA No
4 to 20 mA Yes
Input resistance (4 to 20 mA) 100 Ω
Input ranges (rated values), thermoelements
Type B No
Type E No
Type J No
Type K No
Type L No
Type N No
Type R No
Type S No
Type T No
Type U No
Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 Yes; Standard/climate
Input resistance (Ni 100) 100 MΩ
Ni 1000 Yes
Input resistance (Ni 1000) 100 MΩ
LG-Ni 1000 Yes; Standard/climate
Input resistance (LG-Ni 1000) 100 MΩ
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 Yes; Standard/climate
Input resistance (Pt 100) 100 MΩ
Pt 1000 No
Pt 200 No
Pt 500 No
Input ranges (rated values), resistors
0 to 150 ohms No
0 to 300 ohms No
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 100 MΩ
0 to 6000 ohms Yes
Input resistance (0 to 6000 ohms) 100 MΩ
Thermocouple (TC)
for thermocouples No
Temperature compensation
Parameterizable No
internal temperature compensation No
external temperature compensation with compensations socket No
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 200 m; max. 50 m at 50 mV
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 13 bit
Integration time, parameterizable Yes; 60 / 50 ms
Basic conversion time, ms 66 / 55 ms
Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
Encoder
Connection of signal encoders
for current measurement as 2-wire transducer Yes; with external supply
for current measurement as 4-wire transducer Yes
for resistance measurement with 2-conductor connection Yes
for resistance measurement with 3-conductor connection Yes

 

USER'S manual PDF of 331-1KF02, please refer from Page 357- Page 369:

 

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7331-1KF01-0AB0,

it is 100% compatible with Siemens original part.


Part#: 6ES7331-1KF01-0AB0

Unit price:USD251.00/pc     buy buttom

Description: S7-300 Analog input module
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China


Here, you also need 1 piece of 40 pin front connector to connect with it..

Our compatible 6ES7 392-1AM00-0AA0 can meet your requirements.

 

6ES7 392-1AM00-0AA0  @USD16.90/pc   buy buttom

 

Technical data sheet of our SM 331  6ES7331-1KF01-0AB0

Model

SM331

8AI

Product  Description

8AI;

voltage/current/RTD temperature measurement modules;Resolution:13bits

Optical isolation; high immunity;stable

Power consumption

 

·Rate value

/

·From backplane bus current consumption

90mA

·From L+

/

·Power loss

0.4W

The power of transmitter

 

·Supply current

/

·short-circuit protection

/

Number of analog inputs

8

Cable Length (Shielded)

Max:200m

Input type and input range

 

·voltage

1~5V,0~10V,±50mV

±500mV, ±1V, ±5V, ±10V

·current(4wire)

±20mA, 0~20mA, 4~20mA

·current(2wire)

/

·tesistance

600Ω,6KΩ

·thermocouple

/

·RTD

Pt100(-200℃-850℃)

A/D resolution

13bits

Basic conversion time(per channel)

66/55ms

Interference frequency suppression

50/60Hz

Tolerance(Over entire temperature range)

 

·Voltage

±0.6%

·Current

±0.6%

·resistance

±0.6%

·temperature

±1℃

Interrupts

 

Diagnostic interrupt

None

Limit-value interrupt

None

Isolation tested for contact

 

·Between channels

None

·Between channels and backplane bu

Yes

Front connector

40-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

 331-1KF01-0AB0

 

Pictures of 6ES7331-1KF01-0AB0

331-1KF01 product

3311kf01 3311kf01-00

 

More compatible Siemens S7-200/300 modules we can offer:

 

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

321-1BL00 S7-200 322-1BL00 322-1BH02 S7-300 331-7KF02-0AB0 332-5HD01-0AB0 321-1BL00 3211bl00 6ES7322-1BL00 321-1BH02-0AA0 321-1BH02-0AA0

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 5 2013

6ES7331-7KF02-0AB0 Siemens Analog input module

Introduction to 6ES7331-7KF02-0AB0

SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8AI, RESOLUTION 9/12/14 BITS, U/I/THERMOCOUPLE/RESISTANCE INTERRUPT, DIAGNOSTICS; 1X20PIN REMOVE/INSERT W. BACKPLANE BUS
 

Properties of 6ES7331-7KF02-0AB0

● 8 inputs in 4 channel groups

● Programmable measurement type at each channel group

– Voltage

– Current

– Resistance

– Temperature

● Programmable resolution at each channel group (9/12/14 bits + sign)

● Any measuring range selection per channel group

● Programmable diagnostics and diagnostic interrupt

● Programmable limit value monitoring for 2 channels

● Programmable hardware interrupt when limit is exceeded

● Electrically isolated to CPU and load voltage (not for 2-wire transducers)

Resolution

The measured value resolution is directly proportional to the selected integration time, that is, the measured value resolution increases in proportion to length of the integration time at the analog input channel.

Diagnostics

For information on diagnostics messages at the "group diagnostics" parameter, refer to chapter Diagnostic messages of analog input modules.

Hardware interrupts

Hardware interrupts for channel groups 0 and 1 can be programmed in STEP 7.

However,set a hardware interrupt only for the first channel of a channel group, that is, either at channel 0, or at channel 2.

Terminal assignment

The diagrams below show various wiring options The input impedance depends on the

setting of the measuring range module, see table Measurement types and ranges.

 

Wiring: Voltage measurement

4

 

Measuring range module settings of 6ES7331-7KF02-0AB0

 Measuring range    Measuring range module setting  
 ± 80 mV    A  
 ± 250 mV    
 ± 500 mV    
 ± 1,000 mV    
 ± 2.5 V    B  
 ± 5 V    
 1 V to 5 V    
 ± 10 V    

 

Wiring: 2-wire and 4-wire transducers for current measurement

5

 

Note
The interconnection between MANA and M- (terminals 11, 13, 15, 17, 19) is not required when
using grounded 4-wire transducers with non-isolated supply.

 

Measuring range module settings of 6ES7331-7KF02-0AB0

 Measuring range      Measuring range module setting  
 2-wire transducer    4 mA to 20 mA    D  
 4-wire transducer    ± 3.2 mA    C  
   ± 10 mA    
   0 mA to 20 mA    
   4 mA to 20 mA    
   ± 20 mA    

 

CAUTION
Measuring range module in "Current" position
Any voltage measurement will destroy the measuring range module if "current" measuring mode is set. 

Wiring: 2-, 3- and 4-wire connection of resistance transducers or thermoresistors

6

 

Measuring range module settings

 Measuring range      Measuring range module setting  
 150 Ω      A  
 300 Ω      
 600 Ω      
 Thermoresistor (linear, 4-wire connection)   Pt 100 Klima  A  
(temperature measurement) RTD-4L  Ni 100 Klima  
  Pt 100 Standard  
  Ni 100 Standard  

 

Note
• "Resistance measurement" is only available at one channel per group. The "2nd" channel of the group is used accordingly for current measuring mode (IC). The "1st" channel of the group returns the measured value. The "2nd" channel of the group is assigned the default overflow value "7FFFH."
• There is no compensation for power resistors for "2- and 3-wire connections". 

 

Wiring: Thermocouples with external compensation
Insert a bridge between Comp+ and MANA when using the internal compensation.

7

 

Measuring range module settings

 Measuring range      Measuring range module setting  
Thermocouple TC-I Type N [NiCrSi-NiSi]  A  
(internal comparison) (thermal Type E [NiCr-CuNi]  
voltage measurement) Type J [Fe-CuNi]  
Linearization is ignored Type K [NiCr-Ni]  
Thermocouple TC-E Type L [Fe-CuNi]  
(external comparison)    
(thermovoltage measurement)    
Linearization is ignored    
Thermocouple Type N [NiCrSi-NiSi]  A  
(linear, internal comparison) Type E [NiCr-CuNi]  
(temperature measurement) TCIL Type J [Fe-CuNi]  
Thermocouple Type K [NiCr-Ni]  
(linear, external comparison) Type L [Fe-CuNi]  
(temperature measurement) TCEL    

 

Note
• An interconnection of M- and MANA is prohibited when using grounded thermocouples. In
this case, you must ensure that low-resistance equipotential bonding is in place so that
the permitted common-mode voltage is not exceeded.
• Interconnect M- and MANA when using non-grounded thermocouples 

 

Technical specifications of Analog input module 6ES7331-7KF02-0AB0

      1
SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8AI, RESOLUTION 9/12/14 BITS, U/I/THERMOCOUPLE/RESISTANCE INTERRUPT, DIAGNOSTICS; 1X20PIN REMOVE/INSERT W. BACKPLANE BUS
 
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 200 mA
from backplane bus 5 V DC, max. 50 mA
Power losses
Power loss, typ. 1 W
Analog inputs
Number of analog inputs 8
Number of analog inputs for resistance measurement 4
permissible input voltage for voltage input (destruction limit), max. 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
Voltage Yes
Current Yes
Thermocouple Yes
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), voltages
0 to +10 V No
1 to 5 V Yes
Input resistance (1 to 5 V) 100 kΩ
1 to 10 V No
-1 V to +1 V Yes
Input resistance (-1 V to +1 V) 10 MΩ
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) 100 kΩ
-2.5 V to +2.5 V Yes
Input resistance (-2.5 V to +2.5 V) 100 kΩ
-250 mV to +250 mV Yes
Input resistance (-250 mV to +250 mV) 10 MΩ
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) 100 kΩ
-50 mV to +50 mV No
-500 mV to +500 mV Yes
Input resistance (-500 mV to +500 mV) 10 MΩ
-80 mV to +80 mV Yes
Input resistance (-80 mV to +80 mV) 10 MΩ
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 25 Ω
-10 to +10 mA Yes
Input resistance (-10 to +10 mA) 25 Ω
-20 to +20 mA Yes
Input resistance (-20 to +20 mA) 25 Ω
-3.2 to +3.2 mA Yes
Input resistance (-3.2 to +3.2 mA) 25 Ω
4 to 20 mA Yes
Input resistance (4 to 20 mA) 25 Ω
Input ranges (rated values), thermoelements
Type B No
Type E Yes
Input resistance (Type E) 10 MΩ
Type J Yes
Input resistance (type J) 10 MΩ
Type K Yes
Input resistance (Type K) 10 MΩ
Type L Yes
Input resistance (Type L) 10 MΩ
Type N Yes
Input resistance (Type N) 10 MΩ
Type R No
Type S No
Type T No
Type U No
Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 Yes; Standard
Input resistance (Ni 100) 10 MΩ
Ni 1000 No
LG-Ni 1000 No
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 Yes; Standard
Input resistance (Pt 100) 10 MΩ
Pt 1000 No
Pt 200 No
Pt 500 No
Input ranges (rated values), resistors
0 to 150 ohms Yes
Input resistance (0 to 150 ohms) 10 MΩ
0 to 300 ohms Yes
Input resistance (0 to 300 ohms) 10 MΩ
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 10 MΩ
0 to 6000 ohms No
Thermocouple (TC)
for thermocouples Type E, J, K, L, N
Temperature compensation
Parameterizable Yes
internal temperature compensation Yes
external temperature compensation with compensations socket Yes
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer Pt100 (standard, climatic range), Ni100 (standard, climatic range)
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 200 m; 50 m at 80 mV and thermocouples
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 15 bit; Unipolar: 9/12/12/14 bits; bipolar: 9 bits + sign/12 bits + sign/12 bits + sign/14 bits + sign
Integration time, parameterizable Yes; 2.5/ 16.67/ 20/ 100 ms
Basic conversion time, ms 3 / 17 / 22 /102 ms
Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 Hz
Encoder
Connection of signal encoders
for current measurement as 2-wire transducer Yes
for current measurement as 4-wire transducer Yes
for resistance measurement with 2-conductor connection Yes
for resistance measurement with 3-conductor connection Yes
for resistance measurement with 4-conductor connection Yes
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to input area +/- 1 %; +/-1% (80 mV); +/-0.6% (250 to 1000 mV); +/-0.8% (2.5 to 10 V)
Current, relative to input area +/- 0,7 %; From 3.2 to 20 mA
Impedance, relative to input area +/- 0,7 %; 150, 300, 600 Ohm
Resistance-type thermometer, relative to input area +/- 0,7 %; +/-0.7% (Pt100/ Ni100); +/-0.8% (Pt100 climate)
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0,6 %; +/-0.4% (250 to 1000 mV); +/-0.6 % (2.5 to 10 mV); +/-0.7 % (80 mV)
Current, relative to input area +/- 0,5 %; 3.2 to 20 mA
Impedance, relative to input area +/- 0,5 %; 150, 300, 600 Ohm
Resistance-type thermometer, relative to input area +/- 0,6 %; +/-0.5% (Pt100/ Ni100); +/-0.6% (Pt100 climate)
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Alarms
Diagnostic alarm Yes; Parameterizable, channels 0 and 2
Limit value alarm Yes; Parameterizable
Diagnostic messages
Diagnostic functions Yes; Parameterizable
Diagnostic information readable Yes
Diagnostics Yes
Diagnostics indication LED
Group error SF (red) Yes
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 250 g

 

Measurement types and ranges
Introduction
Module SM 331; AI 8 x 12 Bit has measuring range modules
The measurement type and range is configured at the "measuring range" parameter in STEP 7.
The default setting of the module is "voltage" measurement with "± 10V" range. You can use these default settings without having to program the SM 331; AI 8 x 12 Bit in STEP 7.
Measuring range modules
You may have to change the position of the measuring range modules to suit the measurement type and range (see the chapter Setting the measuring types and ranges of analog input channels ).

The necessary settings are also available on the module's imprint. Mark the position of the measuring range module on the front door.

 

Additional information on SM 331; AI 8 x 12 Bit
Unused channels
As certain programmed inputs may remain unused due to the channel group configuration,make allowances for the special features of these inputs outlined below in order to be able to use the diagnostics functions at these used channels:
● Voltage measurement (except 1 V to 5V) and for thermocouples: Short-circuit unused channels and connect these with MANA. This optimizes interference immunity of the analog input module. Set the "disabled" value at the "measurement type" parameter for unused channels. This setting reduces module cycle times. Also short-circuit the COMP input if this is not used.
● Measuring range 1 V to 5 V: wire the used and unused inputs of the same channel group in parallel.
● Current measurement, 2-wire transducer: There are two options of wiring the channel circuit.
a) Open unused input; channel group diagnostics disabled. If you were to enable diagnostics, the analog module would trigger a single diagnostic interrupt, and light up its SF LED.
b) Loading the unused input using a 1.5 kΩ to 3.3 kΩ resistor. This allows you to enable diagnostics for this channel group.
● Current measurement 4 mA to 20 mA, 4-wire transducer: wire the unused inputs of the same channel group in series.

All channels deactivated
If you disable all input channels of the module and enable diagnostics at the parameters of SM 331; AI 8 x 12 Bit, the module does not report "external auxiliary voltage missing."

Line continuity check for the 4 mA to 20 mA measuring range
If you configured a measuring range of 4 mA to 20 mA, and enabled the line continuity check, the analog input module logs a wire-break event to diagnostics data when the current drops below 3.6 mA.
The module also triggers a diagnostics interrupt if this function is enabled in the program.A wire break can only be signaled by means of the lit SF LED and the diagnostic bytes must be evaluated in the user program if diagnostics interrupts are disabled.
If you configured a measuring range of 4 mA to 20 mA, disabled the line continuity check,and enabled diagnostic interrupts, the module triggers a diagnostic interrupt when the underflow value is reached.

Line continuity check
The line continuity check is designed only for temperature measurements (thermocouples and thermoresistors.)

 

USER'S manual PDF of 331-7KF02, please refer from Page 370- Page 385:

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7331-7KF02-0AB0,

it is 100% compatible with Siemens original part.

Part#: 6ES7331-7KF02-0AB0

 

Unit price:USD367.00/pc  buy buttom
Description: S7-300 Analog input module
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China

 

Here, you need 1 piece of 20pin front connector to connect with 6ES7331-7KF02-0AB0.

Our compatible 6ES7 392-1AJ00-0AA0 can meet your requirements.

 

6ES7 392-1AJ00-0AA0  @USD10.50/pc   buy buttom

 

Technical data sheet of our SM 331  6ES7331-7KF02-0AB0

Model

SM331

8AI

Product  Description

8AI;

Full-function temperature measurement modules; Resolution:16bits;

Short-circuit protection ;High immunity;stable

Power consumption

·Rate value

24V DC

·From backplane bus current consumption

100mA

·From L+

25mA

·Power loss

1W

The power of transmitter

 

·Supply current

Per channel (Max):60mA

·short-circuit protection

Yes

Number of analog inputs

8

Cable Length (Shielded)

200m

Max.For 80mV:50m

Input type and input range

 

·voltage

±80mV, ±250mV,

±500mV,±1V, ±2.5V ±5V,1~5V, ±10V

·current(4wire)

±3.2mA, ±10mA, ±20mA, 4~20mA

·current(2wire)

4~20mA

·tesistance

600Ω, 300Ω, 150Ω,

·thermocouple

K,J,N,E,L

·RTD

Pt100,Ni100

A/D resolution

16bits

Basic conversion time(per channel)

0.5ms/12.5ms/25ms/50ms

Interference frequency suppression

400/60/50/10Hz

Tolerance(Over entire temperature range)

·Voltage

±0.6%

·Current

±0.6%

·resistance

±0.6%

·temperature

±1℃

Interrupts

Diagnostic interrupt

Per group Yes,Configurable

Limit-value interrupt

Yes,Configurable

Isolation tested for contact

·Between channels

None

·Between channels and backplane bu

Yes

Front connector

20-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

 331-7KF02-0AB0

 

Picture of 6ES7331-7KF02-0AB0

331-7KF02-0AB0

More compatible Siemens S7-200/300 modules we can offer:

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

S7-300 322-1BH02 322-1BL00 S7-200 321-1BL00 331-1KF01 product 3311kf01 3311kf01-00

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com

 

May 28 2013

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM332 6ES7 332-5HF00-0AB0 8 AO x 12 BITS

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM332  6ES7 332-5HF00-0AB0   8 AO x 12 BITS

6ES7332-5HF00-0AB0                    SIMATIC S7-300, ANALOG OUTPUT
SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 8 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 40 PIN, REMOVE/INSERT W. ACTIVE, BACKPLANE BUS
Please find below data sheet of Siemens original 6ES7 332-5HF00-0AB0
SM 332 analog output module

-

SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 8 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 40 PIN, REMOVE/INSERT W. ACTIVE, BACKPLANE BUS
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Input current
from load voltage L+ (without load), max. 340 mA
from backplane bus 5 V DC, max. 100 mA
Power losses
Power loss, typ. 6 W
Analog outputs
Number of analog outputs 8
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, max. 25 mA
Current output, no-load voltage, max. 18 V
Output ranges, voltage
0 to 10 V Yes
1 to 5 V Yes
-10 to +10 V Yes
Output ranges, current
0 to 20 mA Yes
-20 to +20 mA Yes
4 to 20 mA Yes
Load impedance (in rated range of output)
with voltage outputs, min. 1 kΩ
with voltage outputs, capacitive load, max. 1 µF
with current outputs, max. 500 Ω
with current outputs, inductive load, max. 10 mH
Cable length
Cable length, shielded, max. 200 m
Analog value creation
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 12 bit; +/-10 V, +/-20 mA, 4 to 20 mA, 1 to 5 V: 11 bits + sign; 0 to 10 V, 0 to 20 mA: 12 bits
Conversion time (per channel) 0.8 ms
Settling time
for resistive load 0.2 ms
for capacitive load 3.3 ms
for inductive load 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to output area +/- 0,5 %
Current, relative to output area +/- 0,6 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to output area +/- 0,4 %
Current, relative to output area +/- 0,5 %
Interrupts/diagnostics/status information
Substitute values connectable Yes; Parameterizable
Alarms
Diagnostic alarm Yes; Parameterizable
Diagnostic messages
Diagnostic information readable Yes
Diagnostics Yes
Diagnostics indication LED
Group error SF (red) Yes
Galvanic isolation
Galvanic isolation analog outputs
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 272 g
Our company have the compatible cable, named 332-5HF00-0AB0,  can replace Siemens 6ES7 332-5HF00-0AB0.You can have a look on the picture.332-5HF00-0AB0

You can get it only need USD554.60/pc.    Buy now ====> buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Please check below discription of our compatible OEM 332-5HF00-0AB0
Model SM3328AO
Product  Description 8AO; Resolution:12bits; High-accuracy
Power consumption
·From bus current consumption 100mA
·From L+ 70mA
·Power loss 6W
Number of analog outputs 8
Load voltage+rated value 24V
Shielded cable length,Max 200m
Voltage output,Max,short circuit Current Yes
Voltage output,Short circuit current(Max) 25mA
Voltage output,Open-circuit current,Max 18V
Load impedance
·Voltage outputs,Min 1KΩ
·current outputs,Max 500Ω
Output ranges
·voltage ±10V,0~10V,1~5V
·current ±20mA,0~20mA,4~20mA
D/A resolution 12bit
conversion time(per channel) Max:0.8ms
Setting time
·Resistive loads 0.1ms
·Capacitive loads 3.3ms
·Inductive loads 0.5ms
Output cross talk >40dB
Tolerance(Over entire temperature range)
·Voltage output ±0.5%
·Current output ±0.6%
Diagnostic interrupt None
Group fault error Red LED
Isolution tested for contact
·Between channels and backplane bus Yes
·Between channels and load voltage L+ Yes
Front connector 40-pin
Dimensions(W x H x D)(mm) 40×125×120
Order Number  332-5HF00-0AB0
Any question, please feel free to contact us.
May 27 2013

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM332 6ES7 332-5HD01-0AB0 4 AO x 12 Bits

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM332  6ES7 332-5HD01-0AB0   4 AO x 12 Bits

 

6ES7332-5HD01-0AB0                   SIMATIC S7-300, ANALOG OUTPUT
SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 4 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 20 PIN, REMOVE/INSERT W. ACTIVE, BACKPLANE BUS
Please check below data sheet of Siemens original 6ES7 332-5HD01-0AB0
SM 332 analog output module

-

SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 4 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 20 PIN, REMOVE/INSERT W. ACTIVE, BACKPLANE BUS
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Input current
from load voltage L+ (without load), max. 240 mA
from backplane bus 5 V DC, max. 60 mA
Power losses
Power loss, typ. 3 W
Analog outputs
Number of analog outputs 4
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, max. 25 mA
Current output, no-load voltage, max. 18 V
Output ranges, voltage
0 to 10 V Yes
1 to 5 V Yes
-10 to +10 V Yes
Output ranges, current
0 to 20 mA Yes
-20 to +20 mA Yes
4 to 20 mA Yes
Load impedance (in rated range of output)
with voltage outputs, min. 1 kΩ
with voltage outputs, capacitive load, max. 1 µF
with current outputs, max. 500 Ω
with current outputs, inductive load, max. 10 mH
Cable length
Cable length, shielded, max. 200 m
Analog value creation
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 12 bit; +/-10 V, +/-20 mA, 4 to 20 mA, 1 to 5 V: 11 bits + sign; 0 to 10 V, 0 to 20 mA: 12 bits
Conversion time (per channel) 0.8 ms
Settling time
for resistive load 0.2 ms
for capacitive load 3.3 ms
for inductive load 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to output area +/- 0,5 %
Current, relative to output area +/- 0,6 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to output area +/- 0,4 %
Current, relative to output area +/- 0,5 %
Interrupts/diagnostics/status information
Substitute values connectable Yes; Parameterizable
Alarms
Diagnostic alarm Yes; Parameterizable
Diagnostic messages
Diagnostic information readable Yes
Diagnostics Yes
Diagnostics indication LED
Group error SF (red) Yes
Galvanic isolation
Galvanic isolation analog outputs
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 220 g
Our company have the compatible cable, named 332-5HD01-0AB0,  can replace Siemens 6ES7 332-5HD01-0AB0.You can have a look on the picture.

332-5HD01-0AB0

You can get it only need USD310.00/pc.    Buy now ====> buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Now, please check below discriptions of our compatible OEM 332-5HD01-0AB0

Model

SM332

4AO

Product  Description 4AO;Resolution:12bits; High-accuracy
Power consumption
·From bus current consumption 40mA
·From L+ 40mA
·Power loss 3W
Number of analog outputs 4
Load voltage+rated value 24V
Shielded cable length,Max 200m
Voltage output,Max,short circuit Current Yes
Voltage output,Short circuit current(Max) 25mA
Voltage output,Open-circuit current,Max 18V
Load impedance
·Voltage outputs,Min 1KΩ
·current outputs,Max 500Ω
Output ranges
·voltage ±10V,0~10V,1~5V
·current ±20mA,0~20mA,4~20mA
D/A resolution 12bit
conversion time(per channel) Max:0.8ms
Setting time
·Resistive loads 0.1ms
·Capacitive loads 3.3ms
·Inductive loads 0.5ms
Output cross talk >40dB
Tolerance(Over entire temperature range)
·Voltage output ±0.5%
·Current output ±0.6%
Diagnostic interrupt None
Group fault error Red LED
Isolution tested for contact
·Between channels and backplane bus Yes
·Between channels and load voltage L+ Yes
Front connector 20-pin
Dimensions(W x H x D)(mm) 40×125×120
Order Number  332-5HD01-0AB0

Any question, please feel free to contact us.
May 26 2013

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM331 6ES7331-7PF11-0AB0 8 AI,TC

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM331  6ES7331-7PF11-0AB0    8 AI,TC
6ES7331-7PF11-0AB0                      SIMATIC S7-300, ANALOG INPUT
SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATATED, 8 AI THERMOCOUPLE, TYPE B, E, J, K, L, N, R, S, T TXK/TXK(L) ACCORDING GOST 16 BIT, 50 MS, 1 X 40 PIN
Please find below data sheet of Siemens original 6ES7331-7PF11-0AB0  :
SM 331 analog input module

-

SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATATED, 8 AI THERMOCOUPLE, TYPE B, E, J, K, L, N, R, S, T TXK/TXK(L) ACCORDING GOST 16 BIT, 50 MS, 1 X 40 PIN
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 200 mA
from backplane bus 5 V DC, max. 100 mA
Power losses
Power loss, typ. 3 W
Analog inputs
Number of analog inputs 8
permissible input voltage for voltage input (destruction limit), max. 75 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20)
Input ranges
Voltage No
Current No
Thermocouple Yes
Resistance thermometer No
Resistance No
Input ranges (rated values), voltages
0 to +10 V No
1 to 5 V No
1 to 10 V No
-1 V to +1 V No
-10 V to +10 V No
-2.5 V to +2.5 V No
-250 mV to +250 mV No
-5 V to +5 V No
-50 mV to +50 mV No
-500 mV to +500 mV No
-80 mV to +80 mV No
Input ranges (rated values), currents
0 to 20 mA No
-10 to +10 mA No
-20 to +20 mA No
-3.2 to +3.2 mA No
4 to 20 mA No
Input ranges (rated values), thermoelements
Type B Yes
Type E Yes
Type J Yes
Type K Yes
Type L Yes
Type N Yes
Type R Yes
Type S Yes
Type T Yes
Type U Yes
Type TXK/TXK(L) to GOST Yes
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 No
Ni 1000 No
LG-Ni 1000 No
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 No
Pt 1000 No
Pt 200 No
Pt 500 No
Input ranges (rated values), resistors
0 to 150 ohms No
0 to 300 ohms No
0 to 600 ohms No
0 to 6000 ohms No
Thermocouple (TC)
for thermocouples Type B, E, J, K, L, N, R, S. T, U, C
Temperature compensation
Parameterizable Yes
internal temperature compensation Yes
external temperature compensation with compensations socket Yes
external temperature compensation with Pt100 Yes
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 100 m
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 16 bit; Two’s complement
Integration time, parameterizable Yes
Basic conversion time, ms Up to 4 channels: 10 ms per module, 5 channels upwards: 190 ms per module
Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 Hz
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to input area +/- 1 K
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Alarms
Diagnostic alarm Yes; Parameterizable per group
Limit value alarm Yes; Parameterizable
Diagnostic messages
Diagnostic functions Yes; Parameterizable
Diagnostic information readable Yes
Diagnostics Yes
Diagnostics indication LED
Group error SF (red) Yes
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels, in groups of 2
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 272 g
Our company have the compatible cable, named 331-7PF11-0AB0,  can replace Siemens 6ES7331-7PF11-0AB0.

You can have a look on the picture.

7PF11-0AB0

You can get it only need USD440.00/pc.    Buy now ====> buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Please find below discription of our compatible OEM 331-7PF11-0AB0:

Model

SM331
8AI Thermocouple

Product  Description

8AI;

Thermocouple temperature measurement modules; Input voltage range:±150mV

Power consumption

·Rate value

24V DC

·From backplane bus current consumption

100mA

·From L+

200mA

·Power loss

3W

The power of transmitter

·Supply current

/

·short-circuit protection

/

Number of analog inputs

8
Cable Length (Shielded) Max:100m

Input type and input range

 

·voltage

±150mV(-32000~+32000)

·current(4wire)

 

·current(2wire)

/

·tesistance

 

·thermocouple

Type:T,E,J,K,N,R,S

·RTD

/

A/D resolution

16bits

Basic conversion time(per channel)

190ms

Interference frequency suppression

400/50/60Hz
Tolerance(Over entire temperature range)

·Voltage

±0.6%

·Current

/

·resistance

/

·temperature

±1℃
Interrupts

Diagnostic interrupt

Per group Yes,Configurable

Limit-value interrupt

Yes,Configurable
Isolation tested for contact

·Between channels

Yes

·Between channels and backplane bu

Yes
Front connector 40-pin

Dimensions(W x H x D)(mm)

40×125×120
Order Number  331-7PF11-0AB0
Any question, please feel free to contact us.
May 25 2013

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM331 6ES7331-7PF01-0AB0 8 AI,RTD

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM331  6ES7331-7PF01-0AB0   8 AI,RTD
6ES7331-7PF01-0AB0                       SIMATIC S7-300, ANALOG INPUT
SIMATIC S7-300, ANALOG INPUT SM 331, OPT. ISOL.,2/3/4 WIRE, 8AI, RESISTANCE, PT100/200/1000 NI100/120/200/500/1000, CU10, PLUS CHARACTERISTICS ACCORDING TO GOST STANDARD 16 (INTERN 24) BIT, 50MS, 1 X 40 PIN
Please find below data sheet of Siemens original 6ES7331-7PF01-0AB0:
Our company have the compatible cable, named 331-7PF01-0AB0,  can replace Siemens 6ES7 331-7PF01-0AB0.

You can have a look on the picture.

7PF01-0AB0

You can get it only need USD440.00/pc.    Buy now ====>buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Here, below is the discription of our compatible OEM 331-7PF01-0AB0:

Model

SM331

8AI RTD

Product  Description

8AI;

RTD temperature measurement modules; stable

Power consumption

·Rate value

24V DC

·From backplane bus current consumption

50mA

·From L+

40mA

·Power loss

1W

The power of transmitter

·Supply current

/

·short-circuit protection

/

Number of analog inputs

8

Cable Length (Shielded)

Max:200m

Input type and input range

·voltage

/

·current(4wire)

/

·current(2wire)

/

·tesistance

150Ω, 300Ω, 600Ω,

·thermocouple

/

·RTD

Pt10、 Pt50、Pt100, Pt200、
Pt500、 Pt1000、 Ni100、
Ni120 、Ni200,Ni500 、
Ni1000 、Cu10(9.035) 、
Cu50、Cu100

A/D resolution

16bits

Basic conversion time(per channel)

190ms

Interference frequency suppression

400/50/60Hz

Tolerance(Over entire temperature range)

·Voltage

/

·Current

/

·resistance

±0.1%

·temperature

±1℃

Interrupts

Diagnostic interrupt

Per group Yes,Configurable

Limit-value interrupt

Yes,Configurable

Isolation tested for contact

·Between channels

Yes

·Between channels and backplane bu

Yes

Front connector

40-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

    331-7PF01-0AB0

Any question, please feel free to contact us.
May 24 2013

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM331 6ES7331-7KF02-0AB0 8AI, 9/12/14BIT

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM331  6ES7331-7KF02-0AB0   8AI, 9/12/14BIT
6ES7331-7KF02-0AB0                SM331, 8AI, 9/12/14BIT
SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8AI, RESOLUTION 9/12/14 BITS, U/I/THERMOCOUPLE/RESISTANCE INTERRUPT, DIAGNOSTICS; 1X20PIN REMOVE/INSERT W. BACKPLANE BUS
Please find below data sheet of Siemens original 6ES7331-7KF02-0AB0:
SM 331 analog input module

-

SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8AI, RESOLUTION 9/12/14 BITS, U/I/THERMOCOUPLE/RESISTANCE INTERRUPT, DIAGNOSTICS; 1X20PIN REMOVE/INSERT W. BACKPLANE BUS
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 200 mA
from backplane bus 5 V DC, max. 50 mA
Power losses
Power loss, typ. 1 W
Analog inputs
Number of analog inputs 8
Number of analog inputs for resistance measurement 4
permissible input voltage for voltage input (destruction limit), max. 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
Voltage Yes
Current Yes
Thermocouple Yes
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), voltages
0 to +10 V No
1 to 5 V Yes
Input resistance (1 to 5 V) 100 kΩ
1 to 10 V No
-1 V to +1 V Yes
Input resistance (-1 V to +1 V) 10 MΩ
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) 100 kΩ
-2.5 V to +2.5 V Yes
Input resistance (-2.5 V to +2.5 V) 100 kΩ
-250 mV to +250 mV Yes
Input resistance (-250 mV to +250 mV) 10 MΩ
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) 100 kΩ
-50 mV to +50 mV No
-500 mV to +500 mV Yes
Input resistance (-500 mV to +500 mV) 10 MΩ
-80 mV to +80 mV Yes
Input resistance (-80 mV to +80 mV) 10 MΩ
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 25 Ω
-10 to +10 mA Yes
Input resistance (-10 to +10 mA) 25 Ω
-20 to +20 mA Yes
Input resistance (-20 to +20 mA) 25 Ω
-3.2 to +3.2 mA Yes
Input resistance (-3.2 to +3.2 mA) 25 Ω
4 to 20 mA Yes
Input resistance (4 to 20 mA) 25 Ω
Input ranges (rated values), thermoelements
Type B No
Type E Yes
Input resistance (Type E) 10 MΩ
Type J Yes
Input resistance (type J) 10 MΩ
Type K Yes
Input resistance (Type K) 10 MΩ
Type L Yes
Input resistance (Type L) 10 MΩ
Type N Yes
Input resistance (Type N) 10 MΩ
Type R No
Type S No
Type T No
Type U No
Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 Yes; Standard
Input resistance (Ni 100) 10 MΩ
Ni 1000 No
LG-Ni 1000 No
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 Yes; Standard
Input resistance (Pt 100) 10 MΩ
Pt 1000 No
Pt 200 No
Pt 500 No
Input ranges (rated values), resistors
0 to 150 ohms Yes
Input resistance (0 to 150 ohms) 10 MΩ
0 to 300 ohms Yes
Input resistance (0 to 300 ohms) 10 MΩ
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 10 MΩ
0 to 6000 ohms No
Thermocouple (TC)
for thermocouples Type E, J, K, L, N
Temperature compensation
Parameterizable Yes
internal temperature compensation Yes
external temperature compensation with compensations socket Yes
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer Pt100 (standard, climatic range), Ni100 (standard, climatic range)
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 200 m; 50 m at 80 mV and thermocouples
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 15 bit; Unipolar: 9/12/12/14 bits; bipolar: 9 bits + sign/12 bits + sign/12 bits + sign/14 bits + sign
Integration time, parameterizable Yes; 2.5/ 16.67/ 20/ 100 ms
Basic conversion time, ms 3 / 17 / 22 /102 ms
Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 Hz
Encoder
Connection of signal encoders
for current measurement as 2-wire transducer Yes
for current measurement as 4-wire transducer Yes
for resistance measurement with 2-conductor connection Yes
for resistance measurement with 3-conductor connection Yes
for resistance measurement with 4-conductor connection Yes
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to input area +/- 1 %; +/-1% (80 mV); +/-0.6% (250 to 1000 mV); +/-0.8% (2.5 to 10 V)
Current, relative to input area +/- 0,7 %; From 3.2 to 20 mA
Impedance, relative to input area +/- 0,7 %; 150, 300, 600 Ohm
Resistance-type thermometer, relative to input area +/- 0,7 %; +/-0.7% (Pt100/ Ni100); +/-0.8% (Pt100 climate)
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0,6 %; +/-0.4% (250 to 1000 mV); +/-0.6 % (2.5 to 10 mV); +/-0.7 % (80 mV)
Current, relative to input area +/- 0,5 %; 3.2 to 20 mA
Impedance, relative to input area +/- 0,5 %; 150, 300, 600 Ohm
Resistance-type thermometer, relative to input area +/- 0,6 %; +/-0.5% (Pt100/ Ni100); +/-0.6% (Pt100 climate)
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Alarms
Diagnostic alarm Yes; Parameterizable, channels 0 and 2
Limit value alarm Yes; Parameterizable
Diagnostic messages
Diagnostic functions Yes; Parameterizable
Diagnostic information readable Yes
Diagnostics Yes
Diagnostics indication LED
Group error SF (red) Yes
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 250 g
Our company have the compatible cable, named 331-7KF02-0AB0,  can replace Siemens 6ES7331-7KF02-0AB0.

You can have a look on the picture.

6ES7331-7KF02-0AB0

You can get it only need USD367.00/pc.    Buy now ====>  buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Below discriptions of our compatible OEM product 331-7KF02-0AB0:

Model

SM331

8AI

Product  Description 8AI;

Full-function temperature measurement modules; Resolution:16bits;

Short-circuit protection ;High immunity;stable

Power consumption
·Rate value 24V DC
·From backplane bus current consumption 100mA
·From L+ 25mA
·Power loss 1W
The power of transmitter  
·Supply current Per channel (Max):60mA
·short-circuit protection Yes
Number of analog inputs 8
Cable Length (Shielded) 200m

Max.For 80mV:50m

Input type and input range  
·voltage ±80mV, ±250mV,

±500mV,±1V, ±2.5V ±5V,1~5V, ±10V

·current(4wire) ±3.2mA, ±10mA, ±20mA, 4~20mA
·current(2wire) 4~20mA
·tesistance 600Ω, 300Ω, 150Ω,
·thermocouple K,J,N,E,L
·RTD Pt100,Ni100
A/D resolution 16bits
Basic conversion time(per channel) 0.5ms/12.5ms/25ms/50ms
Interference frequency suppression 400/60/50/10Hz
Tolerance(Over entire temperature range)
·Voltage ±0.6%
·Current ±0.6%
·resistance ±0.6%
·temperature ±1℃
Interrupts
Diagnostic interrupt Per group Yes,Configurable
Limit-value interrupt Yes,Configurable
Isolation tested for contact
·Between channels None
·Between channels and backplane bu Yes
Front connector 20-pin
Dimensions(W x H x D)(mm) 40×125×120
Order Number  331-7KF02-0AB0
Any question, please feel free to contact us.
May 23 2013

SIEMENS SIMATIC SM7-300 ANALOG MODULE SM331 6ES7331-1KF01-0AB0 8AI, 13BIT

SIEMENS SIMATIC  SM7-300 ANALOG MODULE SM331  6ES7331-1KF01-0AB0  8AI, 13BIT
6ES7331-1KF01-0AB0       SM331, 8AI, 13BIT
SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, 66 MS MODULE UPDATE, 1 X 40 PIN
Here, below is the data sheet of Siemens original 6ES7331-1KF01-0AB0 :
SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, 66 MS MODULE UPDATE, 1 X 40 PIN
Input current
from backplane bus 5 V DC, max. 90 mA
Power losses
Power loss, typ. 0.4 W
Analog inputs
Number of analog inputs 8
Number of analog inputs for resistance measurement 8
permissible input voltage for voltage input (destruction limit), max. 30 V; 12 V continuous, 30 V for max. 1 s
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
Voltage Yes
Current Yes
Thermocouple No
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), voltages
0 to +10 V Yes
Input resistance (0 to 10 V) 100 kΩ
1 to 5 V Yes
Input resistance (1 to 5 V) 100 kΩ
1 to 10 V No
-1 V to +1 V Yes
Input resistance (-1 V to +1 V) 100 kΩ
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) 100 kΩ
-2.5 V to +2.5 V No
-250 mV to +250 mV No
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) 100 kΩ
-50 mV to +50 mV Yes
Input resistance (-50 mV to +50 mV) 100 kΩ
-500 mV to +500 mV Yes
Input resistance (-500 mV to +500 mV) 100 kΩ
-80 mV to +80 mV No
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 50 Ω
-10 to +10 mA No
-20 to +20 mA Yes
Input resistance (-20 to +20 mA) 50 Ω
-3.2 to +3.2 mA No
4 to 20 mA Yes
Input resistance (4 to 20 mA) 50 Ω
Input ranges (rated values), thermoelements
Type B No
Type E No
Type J No
Type K No
Type L No
Type N No
Type R No
Type S No
Type T No
Type U No
Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 Yes; Standard/climate
Input resistance (Ni 100) 100 MΩ
Ni 1000 Yes
Input resistance (Ni 1000) 100 MΩ
LG-Ni 1000 Yes; Standard/climate
Input resistance (LG-Ni 1000) 100 MΩ
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 Yes; Standard/climate
Input resistance (Pt 100) 100 MΩ
Pt 1000 No
Pt 200 No
Pt 500 No
Input ranges (rated values), resistors
0 to 150 ohms No
0 to 300 ohms No
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 100 MΩ
0 to 6000 ohms Yes
Input resistance (0 to 6000 ohms) 100 MΩ
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 200 m; max. 50 m at 50 mV
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 13 bit
Integration time, parameterizable Yes; 60 / 50 ms
Basic conversion time, ms 66 / 55 ms
Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
Encoder
Connection of signal encoders
for current measurement as 2-wire transducer Yes; with external supply
for current measurement as 4-wire transducer Yes
for resistance measurement with 2-conductor connection Yes
for resistance measurement with 3-conductor connection Yes
for resistance measurement with 4-conductor connection Yes
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to input area +/- 0,6 %; +/-0.6% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); +/-0.5% (+/-50 mV, 500 mV, 1 V)
Current, relative to input area +/- 0,5 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA
Impedance, relative to input area +/- 0,5 %; 0 to 6 kohms, 0 to 600 kohms
Resistance-type thermometer, relative to input area 1 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic); 1.2 Kelvin (Pt100, Ni100, standard)
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0,4 %; 0.4% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (+/-50 mV, 500 mV, 1 V)
Current, relative to input area +/- 0,3 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA
Impedance, relative to input area +/- 0,3 %; 0 to 6 kohms, 0 to 600 kohms
Resistance-type thermometer, relative to input area 1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic)
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Alarms
Diagnostic alarm No
Limit value alarm No
Diagnostic messages
Diagnostic functions No
Diagnostic information readable No
Diagnostics No
Group error No
Diagnostics indication LED
Group error SF (red) No
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 117 mm
Weight
Weight, approx. 250 g
Our company have the compatible cable, named 331-1KF01-0AB0,  can replace Siemens 6ES7331-1KF01-0AB0.You can have a look on the picture.

331-1KF01-0AB0

You can get it only need USD251.00/pc.    Buy now ====>  buy buttom

It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

The quality is guaranteed, we have 1 year warranty for our compatible products.

Please find below discription of our compatible 331-1KF01-0AB0:

Model

SM331

8AI

Product  Description

8AI;voltage/current/RTD temperature measurement modules;Resolution:13bits

Optical isolation; high immunity;stable

Power consumption
·Rate value /
·From backplane bus current consumption 90mA
·From L+ /
·Power loss 0.4W

The power of transmitter

·Supply current /
·short-circuit protection /
Number of analog inputs 8
Cable Length (Shielded) Max:200m
Input type and input range
·voltage 1~5V,0~10V,±50mV±500mV, ±1V, ±5V, ±10V
·current(4wire) ±20mA, 0~20mA, 4~20mA
·current(2wire) /
·tesistance 600Ω,6KΩ
·thermocouple /
·RTD Pt100(-200℃-850℃)
A/D resolution 13bits
Basic conversion time(per channel) 66/55ms
Interference frequency suppression 50/60Hz
Tolerance(Over entire temperature range)
·Voltage ±0.6%
·Current ±0.6%
·resistance ±0.6%
·temperature ±1℃
Interrupts
Diagnostic interrupt None
Limit-value interrupt None
Isolation tested for contact
·Between channels None
·Between channels and backplane bu Yes
Front connector 40-pin
Dimensions(W x H x D)(mm) 40×125×120
Order Number  331-1KF01-0AB0