Archive for July, 2013

Jul 9 2013

LOGO!USB-CABLE USB cable for Siemens 6ED1 057-1AA01-0BA0

Introduction to  LOGO!USB-CABLE 6ED1 057-1AA01-0BA0

LOGO! USB PC CABLE FOR PROGRAM TRANSMITTING FROM PC TO LOGO! AND VICE VERSA DRIVER ON CD-ROM INCLUDED
 
 

Product related properties of  LOGO!USB-CABLE 6ED1 057-1AA01-0BA0

Title German LOGO! USB PC Kabel
Title English LOGO! USB PC cable
Type of object (content) Product photo
Search term(s)  
Search items/synonyms
German
Logikmodul LOGO!
Search items/synonyms
English
Logic module LOGO!
Product family LOGO!
Order number (e.g. 1AB1234-1AB12) 6ED1057-1AA01-0BA0

 

6ED1057-1AA01-0BA0

 

Our company (Kollewin Technology CO., Limited) have a new product,

named LOGO!USB-CABLE,

it is 100% compatible with Siemens original part 6ED1 057-1AA01-0BA0.

 

 

Part#:LOGO!USB-CABLE

Unit price: USD45.00/pc     buy buttom

Description: USB isolated adapter
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China

 

logo-usb cable_1

 

More detail description for LOGO!USB-CABLE:

USB optoelectronic isolated cable for Siemens LOGO!,2.5 meters,with communication indicator.

LOGO! USB-CABLE is a programming cable which use the USB interface to achieve the serial connection and the conversion of peripheral port signal. Under the control of computer operation,simulating the computer’s USB interface to traditional serial(commonly known as COM port),thus using the current programming software,communicating software and monitoring software.The work power of the cable comes from USB port and programming port of LOGO! controller.

USB-CABLE is photoelectric isolated,can be applied to LOGO! Controller,especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give permission to the safe operation of the system.

 

LOGO!USB-CABLE’ s chart appearance:

5

 

Characteristics and specifications:

● Support USB-CABLE programming software version:LOGO! Soft V4.0 and above
● Fully compatible with standard USB V2.0
● Power supplied by USB bus and the programming port of LOGO! Controller.
● Optical isolation voltage:1000VDC
● Support UART data format:Data:7、8,stop bit:1、2,check:odd/even/no parity
● Each PC only supports one USB cable
● Working temperature:-20~+75℃
● Cable length:2.5m,color:black

 

 

System requirement
Please make sure your PC is IBM PC compatible and has the following system requirements before using the USB programming cable.
● Intel is compatible with 586DX4-100MHz CPU or higher
● A standard USB port (4-pin A plug)
● Operating system is Windows2000 or Windows XP
 
 
Setting of LOGO!Soft-Comfort
After completing the driver installation,In the Windows Device Manager will come up the COM port of USB-CABLE programming cable,just in the programming of software or other software applications,selecting the COM port.And the follow applyment is exactly the same as the traditional RS232 programmng cable.
Open the main windows form(LOGO!Soft-Comfort),choose “Tools” menu then click “Options…” sub menu and will appear Options setting window.
Select “Interface” Item in the left list,and Choose the COMX interface as it in the Device Manager.
 
6

 

USB-CABLE programming cable can only be used under the device of USB. After completing the driver installation,In the Windows Device Manager will come up the COM port of USB-CABLE programming cable,just in the programming of software or other software applications,selecting the COM port.And the follow applyment is exactly the same as the traditional programming cable.

Note: The maximum extension of the USB cable could reach 5 meters.

The quality is guaranteed.It's tested before shippment.Not made by Siemens,OEM product as the replacement.

 

User's munual PDF of our compatible LOGO!USB-CABLE:

USB isolated adapter–LOGO!USB-CABLE 6ED1 057-1AA01-0BA0

 

More compatible PLC Programming cables of Siemens

CP5611

CP5611-A2

CP5512

CP5512EXP-NEW

PC Adapter CN-NEW

ES-ETH-PPI-NEW

ETH Adapter CN-NEW

USB/PPIM+

PC/PPI

PC/PPI+

USB/MPI+ V4.0

USB/MPI+ V2.0

PC/MPI+ including RS232 cable

PC/MPI

LOGO!USB-CABLE

LOGO!PC-CABLE

MPI extension cable

PC/TTY

 

More pictures of our compatible cables of Siemens parts :

CP5512_1 CP5611-A2_1 CP5512E_1 PC-TTY_1 0CB20-1 V6.0_1 USB-MPI V5.0_1 USB-MPI+V4.0_1 USB-MPI+V2.0_1      

 

Of course, we also supply other compatible PLC Programming cables, such as Mitsubishi/OMRON/Panasonic/GE/Fuji/Schneider/Allen-Bradley/Delta/Proface…

ES-ETH-SC09-NEW

FX-USB-AW

USB-SC09

USB-SC09-FX

SC-09+

SC-10

USB-QC30R2

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

1747-PIC

1747-UIC

1747-CP3

USB-1747-CP3 

1761-CBL-PM02

USB-1761-CBL-PM02

 

More pictures for your reference:

USB-CN226 _1 USB-CIF02_1 TSXPCX3030_1 IC690USB901_1 IC690ACC901_1 USB-1761-CBL-PM02_1 1747-PIC_1 1747-UIC_1 USB-SC09_1 USB-QC30R2 1 ES-ETH-SC09 1 USB-SC09-FX_1 FX-USB-AW 1         

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com

 

Jul 8 2013

USB/MPI+ V4.0: USB to RS485 adapter for Siemens 6ES7 972-0CB20-0XA0

Introduction to 6ES7 972-0CB20-0XA0 

USB/MPI+ V4.0 is the USB to MPI and PPI protocol adapter, support S7-300/400 PLC MPI or S7-200 PLC PPI communication. It’s the same as Siemens PC Adapter USB except that this USB/MPI+ V4.0 doesn’t support profibus communication. Its driver is the Siemens PC_Adapter_USB driver, and choose the USB port, not the COM port.

SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT
 

Properties of the PC Adapter USB  6ES7 972-0CB20-0XA0 

The PC Adapter USB is compatible with USB V1.1 and satisfies the requirements for "Low-Powered“ USB devices. The SIMATIC PC Adapter USB supports the energy saving mode (hibernate mode).

 

Function of PC Adapter USB

The SIMATIC PC Adapter USB connects a PC to the MPI/DP interface of an S7/M7/C7 system via USB. A slot is not required in the PC, which means that the adapter can also be used for non-expandable PCs such as notebooks.

1

 

Note
Only one PC Adapter USB can be used on a PC.

 

Performance specifications of 6ES7 972-0CB20-0XA0
The PC Adapter USB can be used on MPI and PROFIBUS networks. Starting at firmware V1.1, the PC Adapter USB can also be operated on homogeneous PPI networks.
The following table shows the transmission rates and network types supported by the PC Adapter USB.
Tabelle 1 : Busprofile und Übertragungsgeschwindigkeiten

2

 

Other performance features of PC Adapter USB
• Automatic bus profile detection
• Up to 16 communication connections, of those up to 4 slaves (DP/T connections)
• Routing support
• As of firmware V1.3, the PC Adapter USB DPV1 Standard slaves is supported through
- Slave address assignment
- Device diagnosis
- Read/write data record

 

Connecting the PC Adapter USB 6ES7 972-0CB20-0XA0
Connecting to the PC
1 Insert the supplied USB cable into the USB port of your PC.
2 Plug the other end of the USB cable into PC Adapter USB.

Connecting to the PLC
1. Insert the supplied MPI cable into the PC Adapter USB and screw-tighten it.
2. Insert the other end of the MPI cable into the MPI port of your CPU and screwtighten it.


Note
The adapter and the S7/M7/C7 system each represent a network node.
• In networks consisting of two nodes (adapter and S7/M7/C7 system), the adapter is connected directly to the socket of the S7/M7/C7 system.
• When the network contains more than two nodes, the adapter should be connected to the "PG socket“ of a PROFIBUS connector (SINEC L2 bus connector). You do not need to change the settings of the terminating resistors.


Caution
Do not connect the SIMATIC PC Adapter USB to the automation system with any other cable than the supplied MPI cable.

 

Technical data of PC Adater USB 6ES7 972-0CB20-0XA0

       3

SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT
 
Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 100 mA
Power
Power consumption, typ. max. 2.5 W
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes; 6 kV, contact discharge (to IEC 61000-4-2); 8 kV, air discharge (to IEC 61000-4-2)
Interference immunity to cable-borne interference
on the supply lines acc. to IEC 61000-4-4 Yes; 2 kV (to IEC 61000-4-4, burst)
Interference immunity on signal lines acc. to IEC 61000-4-4 Yes; 1 kV (to IEC 61000-4-4; burst; length < 3 m); 2 kV (to IEC 61000-4-4; burst; length > 3 m)
Surge immunity
on the supply lines acc. to IEC 61000-4-5 Yes; 1 kV (to IEC 61000-4-5; surge symm.); 2 kV (to IEC 61000-4-5; surge asymm.)
Immunity against high-frequency electromagnetic fields
Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 Yes; 10 V/m, 80 to 1000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3)
Immunity against conducted interference induced by high-frequency fields
Interference immunity against high frequency current feed acc. to IEC 61000-4-6 Yes; 10 V, 9 kHz to 80 MHz (to IEC 61000-4-6)
Immunity to magnetic field interference
Interference immunity to magnetic fields at 50 Hz 30 A/m; to IEC 61000-4-8
Emission of radio interference acc. to EN 55 022
Interference emission acc. to EN 55022, class B Yes
Ambient conditions
Operating temperature
Min. 5 °C
max. 40 °C
Permissible temperature change 10 °C/h; Operation: 10 K/h; storage/transport: 20 K/h
Storage/transport temperature
Min. -20 °C
max. 60 °C
Relative humidity
Operation, min. 5 %
Operation, max. 80 %; At 25 °C (no condensation)
Storage/transport, min. 5 %
Storage/transport, max. 95 %; At 25 °C (no condensation)
Vibrations
Operation, checked according to IEC 60068-2-6 Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 500 Hz: Acceleration 9.8 m/s2
Transport tested checked to IEC 60068-2-6 Yes; (packed) 5 to 9 Hz, amplitude 3.5 mm; 9 to 500 Hz, acceleration 9.8 m/s2
Shock test
Shock test Tested to DIN IEC 60068-2-2; Operation: 950 m/s2 (10 g), 30 ms, 100 Shocks; Transport (packaged): 250 m/s2 (25 g), 6 ms, 1000 shocks
Dimensions
Width 105 mm
Height 58 mm
Depth 26 mm
Weight
Weight, approx. 100 g

 

USER'S manual PDF of PC adapter USB 6ES7 972-0CB20-0XA0

SIEMENS 6ES7 972-0CB20- PC adapter USB

 

 

Our company (Kollewin Technology CO., Limited) have a new product,

named USB/MPI+V4.0.

It is 100% compatible with Siemens original part.

 

Part#: USB/MPI+V4.0

EX-Work Price: $99.99/pc       buy buttom

 

Approx. Weight: 0.3Kg
Manufacturer: Kollewin
Warranty: 1 year
Origin: China

USB-MPI+V4.0_1

 

Description of PC adapter USB cable USB/MPI+V4.0:

USB/MPI+ V4.0 is the USB to MPI and PPI protocol adapter, support S7-300/400 PLC MPI or S7-200 PLC PPI communication. It’s the same as Siemens PC Adapter USB except that this USB/MPI+ V4.0 doesn’t support profibus communication. Its driver is the Siemens PC_Adapter_USB driver, and choose the USB port, not the COM port.

The working power supply of this cable USB/MPI+ V 4.0 is directly from the USB port, but not the PLC programming interface.
USB/MPI+ V 4.0 is the optoelectronic isolated adapter for industrial design. There is anti-surging& anti-lightning protection circuit for the USB and RS485 interface. It support hot plug. It’s suitable for S7-300/400/200 series PLC. In particular, it applies to the strong interfere industrial scene and the safeguard in the circuit guarantees the safely running of the system.

 

USB/MPI+ principle and figure structure of PC adapter USB cable:


USB-MPI

 

 

 

Indicator

ON

Flash

Off

PWR USB

Power On

Error

Error Or Power off

RxD

Error

Data exchange from PLC

Not Connected

TxD

Error

Data exchange to PLC

No Data exchange

 

Indicator State

 

Functions of PC adapter USB cable USB/MPI+V4.0:
●    Support STEP7 V5.2 and higher,STEP7 Micro/Win 4.0 and higher
●    Fully compatible with USB V2.0
●    Power supply by USB port(100mA). with overcurrent Protection and Surge Protection
●    High optoelectronic isolation voltage up to 1000VDC
●    The USB port design with surge protection.
●    The RS485 port design with overcurrent protection and lightning
protection:Ipp=100A(10/700us,4KV) .Accord to the standard:ITU-TK20/21,VDE0433. ±15KV ESD Protection.
●    Baud rate of MPI port on PLC: 19.2Kbps,187.5Kbps,1.5Mbps. automatically adjust.
●    Baud rate of PPI port on PLC: 9.6Kbps,19.2Kbps,187.5Kbps.
automatically adjust.
●    Support long distance communication up to 1000m
●    Working temperature -20~+75'C
●    Length 3 meters.Color:black
●    One pc supports one USB programming cable only

 

 

Long Distance Communication of PC adapter USB cable USB/MPI+V4.0:
For USB/MPI+ V4.0, the largest communication distance is up to 1000m at the communication speed of 187.5Kbps. It needs to splice 120ohm terminal resistance between 3 and 8 pin on the RS485 port(DB9 Male) to eliminate signal reflection. But requires one PFB-G for each PLC.

 

USB-MPI

 

USER'S MANUAL PDF of our compatible USB/MPI+V2.0:

PC adapter USB cable USB-MPI+ V4.0 USER'S MANUAL

 

Of course, we also have USB/MPI+V5.0  & USB/MPI+V6.0.

Part#: USB/MPI+V5.0

Approx. Weight: 0.3Kg
Manufacturer: Kollewin
Warranty: 1 year
Origin: China

USB-MPI V5.0_1

 

Part#: USB/MPI+V6.0

Approx. Weight: 0.3Kg
Manufacturer: Kollewin
Warranty: 1 year
Origin: China

0CB20-1 V6.0_1

 

More information & price request of our compatibleUSB/MPI+V5.0 & USB/MPI+V6.0 cables, please feel free to contact me.

 

More compatible PLC Programming cables of Siemens

CP5611

CP5611-A2

CP5512

CP5512EXP-NEW

PC Adapter CN-NEW

ES-ETH-PPI-NEW

ETH Adapter CN-NEW

USB/PPIM+

PC/PPI

PC/PPI+

USB/MPI+ V4.0

USB/MPI+ V2.0

PC/MPI+ including RS232 cable

PC/MPI

LOGO!USB-CABLE

LOGO!PC-CABLE

MPI extension cable

PC/TTY

 

 

Here, more pictures of our compatible cables of Siemens parts

CP5512_1 CP5611-A2_1 CP5512E_1 logo-usb cable_1 logo-PC cable_1 PC-TTY_1

 

Of course, we also supply some other brands compatible PLC Programming cables, such as Mitsubishi/OMRON/Panasonic/GE/Fuji/Schneider/Allen-Bradley/Delta/Proface…

ES-ETH-SC09-NEW

FX-USB-AW

USB-SC09

USB-SC09-FX

SC-09+

SC-10

USB-QC30R2

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

1747-PIC

1747-UIC

1747-CP3

USB-1747-CP3 

1761-CBL-PM02

USB-1761-CBL-PM02

 

Pictures for your reference:

USB-CN226 _1 USB-CIF02_1 TSXPCX3030_1 IC690USB901_1 IC690ACC901_1 USB-1761-CBL-PM02_1 1747-PIC_1 1747-UIC_1 USB-SC09_1 USB-QC30R2 1 ES-ETH-SC09 1 USB-SC09-FX_1 FX-USB-AW 1

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 7 2013

6ES7332-5HD01-0AB0 Siemens Analog output module

Introduction to Siemens 6ES7332-5HD01-0AB0

SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 4 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 20 PIN, REMOVE/INSERT W. ACTIVE, BACKPLANE BUS

 

Properties of Siemens 6ES7332-5HD01-0AB0
● 4 outputs in one group
● The output can be selected by individual channel
– Voltage output
– Current output
● Resolution 12 bits
● Programmable diagnostics and diagnostic interrupt
● Electrically isolated to backplane bus interface and load voltage
● Supports parameter reassignment in RUN
Diagnostics
For information on diagnostic messages at the "group diagnostics" parameter, refer to
chapter Diagnostic messages of analog output modules (Page 310).
Terminal assignment
The diagrams below show various wiring options.
Note
When you switch the rated load voltage (L+) off and on, the outputs can return incorrect
voltage/current values for the duration of about 500 ms.

 

Wiring: 2 and 4-wire connection for voltage output
The following Fig. represents the 2-wire connection with no compensation for line resistors
and the 4-wire connection with compensation for line resistors.

8

Wiring: Current output

9

 

Technical specifications of 6ES7332-5HD01-0AB0

     2
   
SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 4 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 20 PIN, REMOVE/INSERT W. ACTIVE, BACKPLANE BUS
 
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Input current
from load voltage L+ (without load), max. 240 mA
from backplane bus 5 V DC, max. 60 mA
Power losses
Power loss, typ. 3 W
Analog outputs
Number of analog outputs 4
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, max. 25 mA
Current output, no-load voltage, max. 18 V
Output ranges, voltage
0 to 10 V Yes
1 to 5 V Yes
-10 to +10 V Yes
Output ranges, current
0 to 20 mA Yes
-20 to +20 mA Yes
4 to 20 mA Yes
Load impedance (in rated range of output)
with voltage outputs, min. 1 kΩ
with voltage outputs, capacitive load, max. 1 µF
with current outputs, max. 500 Ω
with current outputs, inductive load, max. 10 mH
Cable length
Cable length, shielded, max. 200 m
Analog value creation
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 12 bit; +/-10 V, +/-20 mA, 4 to 20 mA, 1 to 5 V: 11 bits + sign; 0 to 10 V, 0 to 20 mA: 12 bits
Conversion time (per channel) 0.8 ms
Settling time
for resistive load 0.2 ms
for capacitive load 3.3 ms
for inductive load 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to output area +/- 0,5 %
Current, relative to output area +/- 0,6 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to output area +/- 0,4 %
Current, relative to output area +/- 0,5 %
Interrupts/diagnostics/status information
Substitute values connectable Yes; Parameterizable
Alarms
Diagnostic alarm Yes; Parameterizable
Diagnostic messages
Diagnostic information readable Yes
Diagnostics Yes
Diagnostics indication LED
Group error SF (red) Yes
Galvanic isolation
Galvanic isolation analog outputs
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 220 g

 

Parameter reassignment in RUN
If you reassign parameters in RUN, the following special characteristic applies.
SF LED is lit:
If a diagnostics was pending prior to reconfiguration, the SF LEDs (on CPU, IM or module)
may be lit even though diagnostics is no longer pending and the module is operating correctly.
Solution:
● Only assign new parameters if no diagnostics is pending, or
● unplug module and plug it in again.

 

Output ranges of SM 332; AO 4 x 12 Bit
Introduction
You can configure the outputs for operation as voltage or current outputs, or disable them.
You program the outputs at the "output type" parameter in STEP 7.
The output type "Voltage" and output range "± 10 V" are set by default at the module. You
can always use this combination of output type and range without having to program the
SM 332; AO 4 x 12 Bit in STEP 7.
Output ranges
Program the voltage and current output ranges in STEP 7.
Output ranges of SM 332; AO 4 x 12 Bit

 Selected type of output    Output range  
 Voltage    1 V to 5 V 0 V to 10 V  
   ± 10 V  
 Current    0 mA to 20 mA  
   4 mA to 20 mA  
   ± 20 mA  

 

Overview of the parameters of SM 332; AO 4 x 12 Bit

10

 

Assigning parameters to channels
The parameters can be set separately at each output channel of SM 332; AO 4 x 12 Bit. You can assign separate parameters to each output channel.
Assign the parameters you set at the SFCs in the user program to the channel groups. Each output channel of SM 332; AO 4 x 12 Bit is thus assigned to a channel group, i.e. output channel 0 > channel group 0, for example.


Note
The output may carry incorrect interim values if you modify output ranges while SM 332;AO 4 x 12 Bit is in RUN.

Additional information on SM 332; AO 4 x 12 Bit

Unused channels
To take unused output channels of SM 332; AO 4 x 12 Bit off power, set the "disabled" argument at the "output type" parameter. Disabled channels do not have to be wired.
Line continuity check
SM 332; AO 4 x 12 Bit only performs a line continuity check at the current outputs.In output ranges 0 mA to 20mA and ±20 mA, a "reliable" wire-break check is not possible for output values of-20s to ±200 μA.
Short-circuit test
SM 332; AO 4 x 12 Bit only performs a short-circuit test at the voltage outputs.
Substitute values
You can configure the SM 332; AO 4 x 12 Bit for CPU STOP mode as follows: Outputs off power, hold last value or set substitute values. The set substitute values must lie within the output range.

 

 

USER'S manual PDF of 332-5HD01, please refer from Page 481- Page 489:

 

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7332-5HD01-0AB0,

it is 100% compatible with Siemens original part.


Part#: 6ES7332-5HD01-0AB0

Unit price:USD310.00/pc     buy buttom

Description: S7-300 Analog onput module
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China


Here, you also need 1 piece of 20pin front connector to connect with it.

Our compatible 6ES7 392-1AJ00-0AA0 can meet your requirements.

 

6ES7 392-1AJ00-0AA0  @USD10.50/pc   buy buttom

 

Technical data sheet of our SM 332  6ES7332-5HD01-0AB0

Model

SM332

4AO

Product  Description

4AO;

 Resolution:12bits; High-accuracy

Power consumption

·From bus current consumption

40mA

·From L+

40mA

·Power loss

3W

Number of analog outputs

4

Load voltage+rated value

24V

Shielded cable length,Max

200m

Voltage output,

Max,short circuit Current

Yes

Voltage output,

Short circuit current(Max)

25mA

Voltage output,

Open-circuit current,Max

18V

Load impedance

·Voltage outputs,Min

1KΩ

·current outputs,Max

500Ω

Output ranges

·voltage

±10V,0~10V,1~5V

·current

±20mA,0~20mA,4~20mA

D/A resolution

12bit

conversion time(per channel)

Max:0.8ms

Setting time

 

·Resistive loads

0.1ms

·Capacitive loads

3.3ms

·Inductive loads

0.5ms

Output cross talk

>40dB

Tolerance(Over entire temperature range)

·Voltage output

±0.5%

·Current output

±0.6%

Diagnostic interrupt

None

Group fault error

Red LED

Isolution tested for contact

 

·Between channels and backplane bus

Yes

·Between channels and load voltage L+

Yes

Front connector

20-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

 332-5HD01-0AB0

 

Picture of 6ES7332-5HD01-0AB0

332-5HD01-0AB0

 

More compatible Siemens S7-200/300 modules we can offer:

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

S7-300 322-1BH02 322-1BL00 S7-200 321-1BL00 331-1KF01 product 3311kf01 3311kf01-00

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 6 2013

6ES7331-1KF01-0AB0 Siemens Analog input module

Introduction to 6ES7331-1KF02-0AB0

 

SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, PTC / KTY, 66 MS MODULE UPDATE, 1 X 40 PIN


Properties of 6ES7331-1KF02-0AB0
● 8 inputs in 8 channel groups
● Programmable resolution at each channel group (12 bits + sign)
● Programmable measurement type per channel group:
– Voltage
– Current
– Resistance
– Temperature
● Any measuring range per channel
● Motor protection / temperature monitoring with PTC in accordance with IEC 60034-11-2
type A
● Temperatures recorded via KTY83/110, KTY84/130 silicon temperature sensors
Terminal assignment
The diagrams below show various wiring options. These examples apply to all channels
(channel 0 to 7).


Note
When connecting voltage and current transducers, make sure that the maximum permitted
common-mode voltage CMV of 2 V is not exceeded between the inputs. Prevent measuring
errors by interconnecting the corresponding M- terminals.

Wiring: Voltage measurement


When connecting voltage and current transducers, make sure that the maximum permitted
common-mode voltage CMV of 2 V is not exceeded between the inputs. Prevent measuring
errors by interconnecting the corresponding M- terminals.

 

Wiring: Voltage measurement

 

1

 

Wiring: 2-wire and 4-wire transducers for current measurement

2

 

Wiring: Resistance measurement with 2-, 3- and 4-wire connection
The following connection possibilities also apply to silicon temperature sensors and PTCs.

3

 

Note
It is not necessary to interconnect the M- terminals when measuring using resistors,
resistance thermometers, PTCs, or silicon temperature sensors. However, interconnection of
the M- terminals may enhance interference immunity.

 

Technical specifications of Analog input module 6ES7331-1KF02-0AB0

       1

SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, PTC / KTY, 66 MS MODULE UPDATE, 1 X 40 PIN
 
Input current
from backplane bus 5 V DC, max. 90 mA
Power losses
Power loss, typ. 0.4 W
Analog inputs
Number of analog inputs 8
Number of analog inputs for resistance measurement 8
permissible input voltage for voltage input (destruction limit), max. 30 V; 12 V continuous, 30 V for max. 1 s
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
Voltage Yes
Current Yes
Thermocouple No
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), voltages
0 to +10 V Yes
Input resistance (0 to 10 V) 100 kΩ
1 to 5 V Yes
Input resistance (1 to 5 V) 100 kΩ
1 to 10 V No
-1 V to +1 V Yes
Input resistance (-1 V to +1 V) 100 kΩ
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) 100 kΩ
-2.5 V to +2.5 V No
-250 mV to +250 mV No
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) 100 kΩ
-50 mV to +50 mV Yes
Input resistance (-50 mV to +50 mV) 100 kΩ
-500 mV to +500 mV Yes
Input resistance (-500 mV to +500 mV) 100 kΩ
-80 mV to +80 mV No
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 100 Ω
-10 to +10 mA No
-20 to +20 mA Yes
Input resistance (-20 to +20 mA) 100 Ω
-3.2 to +3.2 mA No
4 to 20 mA Yes
Input resistance (4 to 20 mA) 100 Ω
Input ranges (rated values), thermoelements
Type B No
Type E No
Type J No
Type K No
Type L No
Type N No
Type R No
Type S No
Type T No
Type U No
Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 Yes; Standard/climate
Input resistance (Ni 100) 100 MΩ
Ni 1000 Yes
Input resistance (Ni 1000) 100 MΩ
LG-Ni 1000 Yes; Standard/climate
Input resistance (LG-Ni 1000) 100 MΩ
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 Yes; Standard/climate
Input resistance (Pt 100) 100 MΩ
Pt 1000 No
Pt 200 No
Pt 500 No
Input ranges (rated values), resistors
0 to 150 ohms No
0 to 300 ohms No
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 100 MΩ
0 to 6000 ohms Yes
Input resistance (0 to 6000 ohms) 100 MΩ
Thermocouple (TC)
for thermocouples No
Temperature compensation
Parameterizable No
internal temperature compensation No
external temperature compensation with compensations socket No
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 200 m; max. 50 m at 50 mV
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 13 bit
Integration time, parameterizable Yes; 60 / 50 ms
Basic conversion time, ms 66 / 55 ms
Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
Encoder
Connection of signal encoders
for current measurement as 2-wire transducer Yes; with external supply
for current measurement as 4-wire transducer Yes
for resistance measurement with 2-conductor connection Yes
for resistance measurement with 3-conductor connection Yes

 

USER'S manual PDF of 331-1KF02, please refer from Page 357- Page 369:

 

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7331-1KF01-0AB0,

it is 100% compatible with Siemens original part.


Part#: 6ES7331-1KF01-0AB0

Unit price:USD251.00/pc     buy buttom

Description: S7-300 Analog input module
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China


Here, you also need 1 piece of 40 pin front connector to connect with it..

Our compatible 6ES7 392-1AM00-0AA0 can meet your requirements.

 

6ES7 392-1AM00-0AA0  @USD16.90/pc   buy buttom

 

Technical data sheet of our SM 331  6ES7331-1KF01-0AB0

Model

SM331

8AI

Product  Description

8AI;

voltage/current/RTD temperature measurement modules;Resolution:13bits

Optical isolation; high immunity;stable

Power consumption

 

·Rate value

/

·From backplane bus current consumption

90mA

·From L+

/

·Power loss

0.4W

The power of transmitter

 

·Supply current

/

·short-circuit protection

/

Number of analog inputs

8

Cable Length (Shielded)

Max:200m

Input type and input range

 

·voltage

1~5V,0~10V,±50mV

±500mV, ±1V, ±5V, ±10V

·current(4wire)

±20mA, 0~20mA, 4~20mA

·current(2wire)

/

·tesistance

600Ω,6KΩ

·thermocouple

/

·RTD

Pt100(-200℃-850℃)

A/D resolution

13bits

Basic conversion time(per channel)

66/55ms

Interference frequency suppression

50/60Hz

Tolerance(Over entire temperature range)

 

·Voltage

±0.6%

·Current

±0.6%

·resistance

±0.6%

·temperature

±1℃

Interrupts

 

Diagnostic interrupt

None

Limit-value interrupt

None

Isolation tested for contact

 

·Between channels

None

·Between channels and backplane bu

Yes

Front connector

40-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

 331-1KF01-0AB0

 

Pictures of 6ES7331-1KF01-0AB0

331-1KF01 product

3311kf01 3311kf01-00

 

More compatible Siemens S7-200/300 modules we can offer:

 

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

321-1BL00 S7-200 322-1BL00 322-1BH02 S7-300 331-7KF02-0AB0 332-5HD01-0AB0 321-1BL00 3211bl00 6ES7322-1BL00 321-1BH02-0AA0 321-1BH02-0AA0

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 5 2013

6ES7331-7KF02-0AB0 Siemens Analog input module

Introduction to 6ES7331-7KF02-0AB0

SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8AI, RESOLUTION 9/12/14 BITS, U/I/THERMOCOUPLE/RESISTANCE INTERRUPT, DIAGNOSTICS; 1X20PIN REMOVE/INSERT W. BACKPLANE BUS
 

Properties of 6ES7331-7KF02-0AB0

● 8 inputs in 4 channel groups

● Programmable measurement type at each channel group

– Voltage

– Current

– Resistance

– Temperature

● Programmable resolution at each channel group (9/12/14 bits + sign)

● Any measuring range selection per channel group

● Programmable diagnostics and diagnostic interrupt

● Programmable limit value monitoring for 2 channels

● Programmable hardware interrupt when limit is exceeded

● Electrically isolated to CPU and load voltage (not for 2-wire transducers)

Resolution

The measured value resolution is directly proportional to the selected integration time, that is, the measured value resolution increases in proportion to length of the integration time at the analog input channel.

Diagnostics

For information on diagnostics messages at the "group diagnostics" parameter, refer to chapter Diagnostic messages of analog input modules.

Hardware interrupts

Hardware interrupts for channel groups 0 and 1 can be programmed in STEP 7.

However,set a hardware interrupt only for the first channel of a channel group, that is, either at channel 0, or at channel 2.

Terminal assignment

The diagrams below show various wiring options The input impedance depends on the

setting of the measuring range module, see table Measurement types and ranges.

 

Wiring: Voltage measurement

4

 

Measuring range module settings of 6ES7331-7KF02-0AB0

 Measuring range    Measuring range module setting  
 ± 80 mV    A  
 ± 250 mV    
 ± 500 mV    
 ± 1,000 mV    
 ± 2.5 V    B  
 ± 5 V    
 1 V to 5 V    
 ± 10 V    

 

Wiring: 2-wire and 4-wire transducers for current measurement

5

 

Note
The interconnection between MANA and M- (terminals 11, 13, 15, 17, 19) is not required when
using grounded 4-wire transducers with non-isolated supply.

 

Measuring range module settings of 6ES7331-7KF02-0AB0

 Measuring range      Measuring range module setting  
 2-wire transducer    4 mA to 20 mA    D  
 4-wire transducer    ± 3.2 mA    C  
   ± 10 mA    
   0 mA to 20 mA    
   4 mA to 20 mA    
   ± 20 mA    

 

CAUTION
Measuring range module in "Current" position
Any voltage measurement will destroy the measuring range module if "current" measuring mode is set. 

Wiring: 2-, 3- and 4-wire connection of resistance transducers or thermoresistors

6

 

Measuring range module settings

 Measuring range      Measuring range module setting  
 150 Ω      A  
 300 Ω      
 600 Ω      
 Thermoresistor (linear, 4-wire connection)   Pt 100 Klima  A  
(temperature measurement) RTD-4L  Ni 100 Klima  
  Pt 100 Standard  
  Ni 100 Standard  

 

Note
• "Resistance measurement" is only available at one channel per group. The "2nd" channel of the group is used accordingly for current measuring mode (IC). The "1st" channel of the group returns the measured value. The "2nd" channel of the group is assigned the default overflow value "7FFFH."
• There is no compensation for power resistors for "2- and 3-wire connections". 

 

Wiring: Thermocouples with external compensation
Insert a bridge between Comp+ and MANA when using the internal compensation.

7

 

Measuring range module settings

 Measuring range      Measuring range module setting  
Thermocouple TC-I Type N [NiCrSi-NiSi]  A  
(internal comparison) (thermal Type E [NiCr-CuNi]  
voltage measurement) Type J [Fe-CuNi]  
Linearization is ignored Type K [NiCr-Ni]  
Thermocouple TC-E Type L [Fe-CuNi]  
(external comparison)    
(thermovoltage measurement)    
Linearization is ignored    
Thermocouple Type N [NiCrSi-NiSi]  A  
(linear, internal comparison) Type E [NiCr-CuNi]  
(temperature measurement) TCIL Type J [Fe-CuNi]  
Thermocouple Type K [NiCr-Ni]  
(linear, external comparison) Type L [Fe-CuNi]  
(temperature measurement) TCEL    

 

Note
• An interconnection of M- and MANA is prohibited when using grounded thermocouples. In
this case, you must ensure that low-resistance equipotential bonding is in place so that
the permitted common-mode voltage is not exceeded.
• Interconnect M- and MANA when using non-grounded thermocouples 

 

Technical specifications of Analog input module 6ES7331-7KF02-0AB0

      1
SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8AI, RESOLUTION 9/12/14 BITS, U/I/THERMOCOUPLE/RESISTANCE INTERRUPT, DIAGNOSTICS; 1X20PIN REMOVE/INSERT W. BACKPLANE BUS
 
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 200 mA
from backplane bus 5 V DC, max. 50 mA
Power losses
Power loss, typ. 1 W
Analog inputs
Number of analog inputs 8
Number of analog inputs for resistance measurement 4
permissible input voltage for voltage input (destruction limit), max. 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
Voltage Yes
Current Yes
Thermocouple Yes
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), voltages
0 to +10 V No
1 to 5 V Yes
Input resistance (1 to 5 V) 100 kΩ
1 to 10 V No
-1 V to +1 V Yes
Input resistance (-1 V to +1 V) 10 MΩ
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) 100 kΩ
-2.5 V to +2.5 V Yes
Input resistance (-2.5 V to +2.5 V) 100 kΩ
-250 mV to +250 mV Yes
Input resistance (-250 mV to +250 mV) 10 MΩ
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) 100 kΩ
-50 mV to +50 mV No
-500 mV to +500 mV Yes
Input resistance (-500 mV to +500 mV) 10 MΩ
-80 mV to +80 mV Yes
Input resistance (-80 mV to +80 mV) 10 MΩ
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 25 Ω
-10 to +10 mA Yes
Input resistance (-10 to +10 mA) 25 Ω
-20 to +20 mA Yes
Input resistance (-20 to +20 mA) 25 Ω
-3.2 to +3.2 mA Yes
Input resistance (-3.2 to +3.2 mA) 25 Ω
4 to 20 mA Yes
Input resistance (4 to 20 mA) 25 Ω
Input ranges (rated values), thermoelements
Type B No
Type E Yes
Input resistance (Type E) 10 MΩ
Type J Yes
Input resistance (type J) 10 MΩ
Type K Yes
Input resistance (Type K) 10 MΩ
Type L Yes
Input resistance (Type L) 10 MΩ
Type N Yes
Input resistance (Type N) 10 MΩ
Type R No
Type S No
Type T No
Type U No
Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 Yes; Standard
Input resistance (Ni 100) 10 MΩ
Ni 1000 No
LG-Ni 1000 No
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 Yes; Standard
Input resistance (Pt 100) 10 MΩ
Pt 1000 No
Pt 200 No
Pt 500 No
Input ranges (rated values), resistors
0 to 150 ohms Yes
Input resistance (0 to 150 ohms) 10 MΩ
0 to 300 ohms Yes
Input resistance (0 to 300 ohms) 10 MΩ
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 10 MΩ
0 to 6000 ohms No
Thermocouple (TC)
for thermocouples Type E, J, K, L, N
Temperature compensation
Parameterizable Yes
internal temperature compensation Yes
external temperature compensation with compensations socket Yes
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer Pt100 (standard, climatic range), Ni100 (standard, climatic range)
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 200 m; 50 m at 80 mV and thermocouples
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 15 bit; Unipolar: 9/12/12/14 bits; bipolar: 9 bits + sign/12 bits + sign/12 bits + sign/14 bits + sign
Integration time, parameterizable Yes; 2.5/ 16.67/ 20/ 100 ms
Basic conversion time, ms 3 / 17 / 22 /102 ms
Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 Hz
Encoder
Connection of signal encoders
for current measurement as 2-wire transducer Yes
for current measurement as 4-wire transducer Yes
for resistance measurement with 2-conductor connection Yes
for resistance measurement with 3-conductor connection Yes
for resistance measurement with 4-conductor connection Yes
Errors/accuracies
Operational limit in overall temperature range
Voltage, relative to input area +/- 1 %; +/-1% (80 mV); +/-0.6% (250 to 1000 mV); +/-0.8% (2.5 to 10 V)
Current, relative to input area +/- 0,7 %; From 3.2 to 20 mA
Impedance, relative to input area +/- 0,7 %; 150, 300, 600 Ohm
Resistance-type thermometer, relative to input area +/- 0,7 %; +/-0.7% (Pt100/ Ni100); +/-0.8% (Pt100 climate)
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0,6 %; +/-0.4% (250 to 1000 mV); +/-0.6 % (2.5 to 10 mV); +/-0.7 % (80 mV)
Current, relative to input area +/- 0,5 %; 3.2 to 20 mA
Impedance, relative to input area +/- 0,5 %; 150, 300, 600 Ohm
Resistance-type thermometer, relative to input area +/- 0,6 %; +/-0.5% (Pt100/ Ni100); +/-0.6% (Pt100 climate)
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Alarms
Diagnostic alarm Yes; Parameterizable, channels 0 and 2
Limit value alarm Yes; Parameterizable
Diagnostic messages
Diagnostic functions Yes; Parameterizable
Diagnostic information readable Yes
Diagnostics Yes
Diagnostics indication LED
Group error SF (red) Yes
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 250 g

 

Measurement types and ranges
Introduction
Module SM 331; AI 8 x 12 Bit has measuring range modules
The measurement type and range is configured at the "measuring range" parameter in STEP 7.
The default setting of the module is "voltage" measurement with "± 10V" range. You can use these default settings without having to program the SM 331; AI 8 x 12 Bit in STEP 7.
Measuring range modules
You may have to change the position of the measuring range modules to suit the measurement type and range (see the chapter Setting the measuring types and ranges of analog input channels ).

The necessary settings are also available on the module's imprint. Mark the position of the measuring range module on the front door.

 

Additional information on SM 331; AI 8 x 12 Bit
Unused channels
As certain programmed inputs may remain unused due to the channel group configuration,make allowances for the special features of these inputs outlined below in order to be able to use the diagnostics functions at these used channels:
● Voltage measurement (except 1 V to 5V) and for thermocouples: Short-circuit unused channels and connect these with MANA. This optimizes interference immunity of the analog input module. Set the "disabled" value at the "measurement type" parameter for unused channels. This setting reduces module cycle times. Also short-circuit the COMP input if this is not used.
● Measuring range 1 V to 5 V: wire the used and unused inputs of the same channel group in parallel.
● Current measurement, 2-wire transducer: There are two options of wiring the channel circuit.
a) Open unused input; channel group diagnostics disabled. If you were to enable diagnostics, the analog module would trigger a single diagnostic interrupt, and light up its SF LED.
b) Loading the unused input using a 1.5 kΩ to 3.3 kΩ resistor. This allows you to enable diagnostics for this channel group.
● Current measurement 4 mA to 20 mA, 4-wire transducer: wire the unused inputs of the same channel group in series.

All channels deactivated
If you disable all input channels of the module and enable diagnostics at the parameters of SM 331; AI 8 x 12 Bit, the module does not report "external auxiliary voltage missing."

Line continuity check for the 4 mA to 20 mA measuring range
If you configured a measuring range of 4 mA to 20 mA, and enabled the line continuity check, the analog input module logs a wire-break event to diagnostics data when the current drops below 3.6 mA.
The module also triggers a diagnostics interrupt if this function is enabled in the program.A wire break can only be signaled by means of the lit SF LED and the diagnostic bytes must be evaluated in the user program if diagnostics interrupts are disabled.
If you configured a measuring range of 4 mA to 20 mA, disabled the line continuity check,and enabled diagnostic interrupts, the module triggers a diagnostic interrupt when the underflow value is reached.

Line continuity check
The line continuity check is designed only for temperature measurements (thermocouples and thermoresistors.)

 

USER'S manual PDF of 331-7KF02, please refer from Page 370- Page 385:

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7331-7KF02-0AB0,

it is 100% compatible with Siemens original part.

Part#: 6ES7331-7KF02-0AB0

 

Unit price:USD367.00/pc  buy buttom
Description: S7-300 Analog input module
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China

 

Here, you need 1 piece of 20pin front connector to connect with 6ES7331-7KF02-0AB0.

Our compatible 6ES7 392-1AJ00-0AA0 can meet your requirements.

 

6ES7 392-1AJ00-0AA0  @USD10.50/pc   buy buttom

 

Technical data sheet of our SM 331  6ES7331-7KF02-0AB0

Model

SM331

8AI

Product  Description

8AI;

Full-function temperature measurement modules; Resolution:16bits;

Short-circuit protection ;High immunity;stable

Power consumption

·Rate value

24V DC

·From backplane bus current consumption

100mA

·From L+

25mA

·Power loss

1W

The power of transmitter

 

·Supply current

Per channel (Max):60mA

·short-circuit protection

Yes

Number of analog inputs

8

Cable Length (Shielded)

200m

Max.For 80mV:50m

Input type and input range

 

·voltage

±80mV, ±250mV,

±500mV,±1V, ±2.5V ±5V,1~5V, ±10V

·current(4wire)

±3.2mA, ±10mA, ±20mA, 4~20mA

·current(2wire)

4~20mA

·tesistance

600Ω, 300Ω, 150Ω,

·thermocouple

K,J,N,E,L

·RTD

Pt100,Ni100

A/D resolution

16bits

Basic conversion time(per channel)

0.5ms/12.5ms/25ms/50ms

Interference frequency suppression

400/60/50/10Hz

Tolerance(Over entire temperature range)

·Voltage

±0.6%

·Current

±0.6%

·resistance

±0.6%

·temperature

±1℃

Interrupts

Diagnostic interrupt

Per group Yes,Configurable

Limit-value interrupt

Yes,Configurable

Isolation tested for contact

·Between channels

None

·Between channels and backplane bu

Yes

Front connector

20-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

 331-7KF02-0AB0

 

Picture of 6ES7331-7KF02-0AB0

331-7KF02-0AB0

More compatible Siemens S7-200/300 modules we can offer:

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

S7-300 322-1BH02 322-1BL00 S7-200 321-1BL00 331-1KF01 product 3311kf01 3311kf01-00

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com

 

Jul 4 2013

6ES7321-1BH02-0AA0 Siemens Digital input module

Introduction to 6ES7321-1BH02-0AA0

SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED, 16DI, 24 V DC, 1 X 20 PIN

Order number: "SIPLUS S7-300 module"
6AG1321-1BH02-2AA0
Properties
Properties of SM 321; DI 16 x DC 24 V:
● 16 inputs, electrically isolated in groups of 16
● Rated input voltage 24 VDC
● suitable for switches and 2- /3-/4-wire proximity switches (BEROs)

 

Wiring and block diagrams of SM 321; DI 16 x DC 24 V

14

 

Technical specifications of 6ES7321-1BH02-0AA0

        5
 
SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED, 16DI, 24 V DC, 1 X 20 PIN
 
Supply voltage
Load voltage L+
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Input current
from backplane bus 5 V DC, max. 10 mA
Power losses
Power loss, typ. 3.5 W
Digital inputs
Number/binary inputs 16
Input characteristic curve acc. to IEC 61131, Type 1 Yes
Number of simultaneously controllable inputs
horizontal installation
up to 40 °C, max. 16
up to 60 °C, max. 16
vertical installation
up to 40 °C, max. 16
Input voltage
Type of input voltage DC
Rated value, DC 24 V
for signal "0" -30 to +5 V
for signal "1" 13 to 30 V
Input current
for signal "1", typ. 7 mA
Input delay (for rated value of input voltage)
for standard inputs
Parameterizable No
at "0" to "1", min. 1.2 ms
at "0" to "1", max. 4.8 ms
Cable length
Cable length, shielded, max. 1000 m
Cable length unshielded, max. 600 m
Encoder
Connectable encoders
2-wire sensor Yes
Permissible quiescent current (2-wire sensor), max. 1.5 mA
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Alarms
Alarms No
Diagnostic alarm No
Hardware interrupt No
Diagnostic messages
Diagnostic functions No
Diagnostics indication LED
Status indicator digital input (green) Yes
Galvanic isolation
Galvanic isolation digital inputs
between the channels No
between the channels, in groups of 16
between the channels and the backplane bus Yes; Optocoupler
Permissible potential difference
between different circuits 75 VDC / 60 VAC
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 200 g

 

USER'S manual PDF of 321-1BH02, please refer from Page 79- Page 82:

 

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7321-1BH02-0AA0,

it is 100% compatible with Siemens original part.


Part#: 6ES7321-1BH02-0AA0

 

Unit price:USD95.00/pc  buy buttom
Description: S7-300
Digital input module
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China


Here, you need 1 piece of 40pin front connector to connect with 6ES7321-1BH02-0AA0.

Our compatible 6ES7 392-1AM00-0AA0 can meet your requirements.

6ES7 392-1AM00-0AA0  @USD16.90/pc   buy buttom

 

 

Technical data sheet of our SM 321  6ES7321-1BH02-0AA0

Model

SM321

Number of digital inputs:32

Product  Description

32DI 24V DC,
High immunity

 

Power consumption

·From bus current consumption

50mA

·Power loss

6.5W

Number of digital inputs

32

Cable Length (Shielded)

1,000m

Cable Length (unshielded)

600m

Input voltage

·Rate value

24V DC

·For ”0” signal

-30~5V DC

·For ”1” signal

13~30V DC

·Frequency range

/

Input current

7mA

Input delay

 

·From “0”  to “1”,Min

1.2~4.8ms

·From “1”  to “0”,Min

1.2~4.8ms

Front connector

40-pin

Input type

NPN

Connection of 2-wire BERO sensor

Yes

Permissible quiescent current

1.5mA

Isolation tested for contact

·Between channel and backplane bus

Yes

·Per group between channels

Yes

The status indicates

Green LED each channel

Dimensions(WxHx D)(mm)

40×125×120

Order Number

 321-1BL00-0AA0

 

Pictures of 6ES7321-1BH02-0AA0

321-1BH02-0AA0

322-1BH02

 

More compatible Siemens S7-200/300 modules we can offer:

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

6ES7322-1BL00 3211bl00 321-1BL00 332-5HD01-0AB0 S7-300 322-1BL00 S7-200 331-1KF01 product 321-1BL00 3311kf01 3311kf01-00

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 3 2013

6ES7321-1BL00-0AA0 Siemens Digital input module

Introduction to 6ES7321-1BL00-0AA0

SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED 32DI, 24 V DC, 1 X 40 PIN

Order number: "Standard module"
6ES7321-1BL00-0AA0
Order number: "SIPLUS S7-300 module"
6AG1321-1BL00-2AA0
Properties
Properties of SM 321; DI 32 x DC 24 V:
● 32 inputs, isolated in groups of 16
● Rated input voltage 24 VDC
● Suitable for switches and 2-/3-/4-wire proximity switches (BEROs)

 

Wiring and block diagrams of SM 321; DI 32 x DC 24 V

11

 

Terminal assignment of SM 321; DI 32 x DC 24 V
The figure below shows how channels are assigned to addresses (input byte x up to input byte x+3).

12

 

Technical specifications of SM 321; DI 32 x DC 24 V

        3
 
SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED 32DI, 24 V DC, 1 X 40 PIN
 
Supply voltage
Load voltage L+
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Input current
from backplane bus 5 V DC, max. 15 mA
Power losses
Power loss, typ. 6.5 W
Digital inputs
Number/binary inputs 32
Input characteristic curve acc. to IEC 61131, Type 1 Yes
Number of simultaneously controllable inputs
horizontal installation
up to 40 °C, max. 32
up to 60 °C, max. 16
vertical installation
up to 40 °C, max. 32
Input voltage
Type of input voltage DC
Rated value, DC 24 V
for signal "0" -30 to +5 V
for signal "1" 13 to 30 V
Input current
for signal "1", typ. 7 mA
Input delay (for rated value of input voltage)
for standard inputs
Parameterizable No
at "0" to "1", min. 1.2 ms
at "0" to "1", max. 4.8 ms
Cable length
Cable length, shielded, max. 1000 m
Cable length unshielded, max. 600 m
Encoder
Connectable encoders
2-wire sensor Yes
Permissible quiescent current (2-wire sensor), max. 1.5 mA
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Alarms
Alarms No
Diagnostic alarm No
Hardware interrupt No
Diagnostic messages
Diagnostic functions No
Diagnostics indication LED
Status indicator digital input (green) Yes
Galvanic isolation
Galvanic isolation digital inputs
between the channels No
between the channels, in groups of 16
between the channels and the backplane bus Yes; Optocoupler
Permissible potential difference
between different circuits 75 VDC / 60 VAC
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 260 g

 

USER'S manual PDF of 321-1BL00, please refer to Page 72- Page 75:

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7321-1BL00-0AA0,

it is 100% compatible with Siemens original part.


Part#: 6ES7321-1BL00-0AA0

Unit price:USD191.00/pc  buy buttom
Description: S7-300 Digital input module
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China

 

Here, you also need 1 piece of 40 pin front connector to connect with it..

Our compatible 6ES7 392-1AM00-0AA0 can meet your requirements.

 

6ES7 392-1AM00-0AA0  @USD16.90/pc   buy buttom

 

Technical data sheet of our SM 321  6ES7321-1BL00-0AA0

Model

SM321

Number of digital inputs:32

Product  Description

32DI 24V DC,
High immunity

 

Power consumption

·From bus current consumption

50mA

·Power loss

6.5W

Number of digital inputs

32

Cable Length (Shielded)

1,000m

Cable Length (unshielded)

600m

Input voltage

·Rate value

24V DC

·For ”0” signal

-30~5V DC

·For ”1” signal

13~30V DC

·Frequency range

/

Input current

7mA

Input delay

 

·From “0”  to “1”,Min

1.2~4.8ms

·From “1”  to “0”,Min

1.2~4.8ms

Front connector

40-pin

Input type

NPN

Connection of 2-wire BERO sensor

Yes

Permissible quiescent current

1.5mA

Isolation tested for contact

·Between channel and backplane bus

Yes

·Per group between channels

Yes

The status indicates

Green LED each channel

Dimensions(WxHx D)(mm)

40×125×120

Order Number

 321-1BL00-0AA0

 

Pictures of 6ES7321-1BL00-0AA0

321-1BL00

3211bl00

More compatible Siemens S7-200/300 modules we can offer:

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

332-5HD01-0AB0 331-7KF02-0AB0 S7-300 322-1BH02 322-1BL00 S7-200 331-1KF01 product 3311kf01 3311kf01-00

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 2 2013

6ES7322-1BL00-0AA0 Siemens Digital output module

Introduction to 6ES7322-1BL00-0AA0

SIMATIC S7-300, DIGITAL OUTPUT SM 322, OPTICALLY ISOLATED, 32DO, 24V DC, 0.5A, 1 X 40 PIN, SUM OF OUTPUT CURRENTS 4A/GROUP (16A/MODULE)

 

Properties of 6ES7322-1BL00-0AA0
● 32 outputs, electrically isolated in groups of 8
● Output current 0.5 A
● Rated load voltage 24 VDC
● Suitable for solenoid valves, DC contactors and signal lamps
Use of the module with high-speed counters

Please note when using the module in combination with high-speed counters:
Note
When using a mechanical contact to switch on the 24-V power supply to SM 322;
DO 32 x DC 24 V/0.5 A, its outputs will carry "1" signal for the duration of ca. 50 μs due to the circuit structure.

 

Wiring and block diagram of SM 322; DO 32 x DC 24 V/ 0.5 A

13

 

Terminal assignment of SM 322; DO 32 x DC 24 V/ 0.5 A
The figure below shows the channel addressing (output byte x to output byte x+3).

12

 

Technical specifications of SM 322; 6ES7322-1BL00-0AA0


    4
SIMATIC S7-300, DIGITAL OUTPUT SM 322, OPTICALLY ISOLATED, 32DO, 24V DC, 0.5A, 1 X 40 PIN, SUM OF OUTPUT CURRENTS 4A/GROUP (16A/MODULE)
 
Supply voltage
Load voltage L+
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Input current
from load voltage L+ (without load), max. 160 mA
from backplane bus 5 V DC, max. 110 mA
Power losses
Power loss, typ. 6.6 W
Digital outputs
Number/binary outputs 32
Limitation of inductive shutdown voltage to L+ (-53 V)
Lamp load, max. 5 W
Load resistance range
lower limit 48 Ω
upper limit 4 kΩ
Output voltage
for signal "1", min. L+ (-0.8 V)
Output current
for signal "1" rated value 0.5 A
for signal "1" permissible range for 0 to 40 °C, max. 0.6 A
for signal "1" minimum load current 5 mA
for signal "0" residual current, max. 0.5 mA
Switching frequency
with resistive load, max. 100 Hz
with inductive load, max. 0.5 Hz
on lamp load, max. 10 Hz
Aggregate current of outputs (per group)
horizontal installation
up to 40 °C, max. 4 A
up to 60 °C, max. 3 A
vertical installation
up to 40 °C, max. 2 A
Cable length
Cable length, shielded, max. 1000 m
Cable length unshielded, max. 600 m
Interrupts/diagnostics/status information
Alarms
Diagnostic alarm No
Diagnostic messages
Diagnostics No
Wire break No
Short circuit No
Missing load voltage No
Diagnostics indication LED
Rated load voltage PWR (green) No
Fuse OK FSG (green) No
Galvanic isolation
Galvanic isolation digital outputs
between the channels, in groups of 8
between the channels and the backplane bus Yes; Optocoupler
Isolation
Isolation checked with 500 V DC
Connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weight
Weight, approx. 260 g

 

USER'S manual PDF of 322-1BL00, please refer to Page 143- Page 146:

S7-300 Modules data & USER'S MANUAL

 

Our company (Kollewin Technology CO., Limited) have a new product,

named 6ES7322-1BL00-0AA0.

It is 100% compatible with Siemens original part.


Part#: 6ES7322-1BL00-0AA0

Unit price:USD264.00/pc  buy buttom
Manufacturer: Kollewin
Approx. Weight: 0.3 Kg
Warranty: 1 year
Origin: China


Here, you need 1 pc 40pin front connector to connect with it.

Our compatible 6ES7 392-1AM00-0AA0 can meet your requirements.

6ES7 392-1AM00-0AA0  @USD16.90/pc   buy buttom

 

Technical data sheet of our SM 322  6ES7322-1BL00-0AA0

Model

SM322

Number of digital outputs:32

Product  Description

32DO,24V DC; Transistor;

Optical isolation with high immunity

Power consumption

·From  bus current consumption

90mA

·Power loss

6W

Number of digital outputs

32

Cable Length (Shielded)

1,000m

Cable Length (unshielded)

600m

Short-circuit protection

Yes,Electronic

Inductive cutoff voltage

L+(-53V)

Lamp load Max

5W

Output voltage:”1” signal

Min,L+(-0.8V)

Output current:”1” signal

0.5A

Lifetime contact mechanical

/

Lifetime contact  mechanical  rated load voltage)

/

Sum of output currents(per group)

4A

IIsolation tested for contact

·To backplane bus

Yes,Optocoupler

·To per group between channels

Yes

Switching frequency for contacts

·Resistive loads,Max

100Hz

·Capacitive loads,Max

0.5Hz

·Lamp loads,Max

10Hz

·Mechanical load,Max

/

The status indicates

Green LED each channel

Front connector

40-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

 322-1BL00-0AA0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pictures of 6ES7322-1BL00-0AA0

322-1BL00 6ES7322-1BL00

 

More compatible Siemens S7-200/300 modules we can offer:

Model Product Description
SM7-200 DIGITAL MODULE
  6ES7221-1BH22-0XA0 EM221 16 DI 24V DC
  6ES7221-1BL22-0XA0 EM221 32 DI 24V DC
  6ES7222-1BF22-0XA0 EM222 8DO,DC 24V
  6ES7222-1HF22-0XA0   EM222 8DO,relay
  6ES7222-1BH22-0XA0 EM222 16 DO 24V DC
  6ES7222-1HH22-0XA0 EM222 16 DO RELAY
  6ES7222-1BL22-0XA0 EM222 32 DO 24V DC
  6ES7223-1HF22-0XA0 EM223 4DI/4DO,DC 24V relay
  6ES7223-1BH22-0XA0 EM223 8 DI/ 8 DO 24V DC
  6ES7223-1PH22-0XA0 EM223 8 DI 24V DC/8 DO RELAY
  6ES7223-1BL22-0XA0 EM223 16 DI/ 16 DO 24V DC
  6ES7223-1PL22-0XA0 EM223 16 DI 24V DC/ 16 DO RELAY
  6ES7223-1BF22-0XA0 4 DI/4DO,24 VDC
  6ES7221-1BF22-0XA0 8 DI,24V DC
SM7-200 ANALOG MODULE
  6ES7231-0HC22-0XA0 EM231 4 AI x 12 Bits
  6ES7231-0HF22-0XA0 EM231 8 AI x 12/11 BIT 
  6ES7231-7PC22-0XA0 EM231 4 RTD
  6ES7231-7PD22-0XA0 EM231 4 TC
  6ES7231-7PH22-0XA0 EM231 8 TC
  6ES7231-7PL22-0XA0 16AI, T/C INPUT MOD, 16BIT
  6ES7231-7PB22-0XA0 2AI, RTD INPUT MOD. 16BIT 
  6ES7232-0HB22-0XA0 EM232 2 AO x 12 Bits
  6ES7232-0HD22-0XA0 EM232 4 AO x 12 Bits
  6ES7235-0KD22-0XA0 EM235 4 AI/ 1 AO x 12 Bits
SM7-300 DIGITAL MODULE
  6ES7321-1BH02-0AA0 SM321 16 DI 24 VDC
  6ES7321-1FH00-0AA0 SM321 16 DI  AC 230V
  6ES7321-1BL00-0AA0 SM321 32 DI 24 VDC
  6ES7322-1BF01-0AA0 SM322,8DO,24VDC,2A
  6ES7322-1BH01-0AA0 SM322 16 DO 24 VDC/ 0.5A
  6ES7322-1HH01-0AA0 SM322 16 DO RELAY
  6ES7322-1BL00-0AA0 SM322 32 DO 24V DC/0.5A
  6ES7323-1BL00-0AA0 SM323 16DI 24V DC/ 16DO 24V DC 0.5A
SM7-300 ANALOG MODULE
  6ES7331-1KF01-0AB0 SM331 8 AI x 13 Bits
  6ES7331-7KF02-0AB0 SM331 8 AI X 14 Bits
  6ES7331-7PF01-0AB0 SM331 8 AI,RTD
  6ES7331-7PF11-0AB0 SM331 8 AI,TC
  6ES7332-5HD01-0AB0 SM332 4 AO x 12 Bits
  6ES7332-5HF00-0AB0 SM 332 8 AO x 12 BITS
SIMATIC DP  IM 153 
  6ES7153-1AA03-0XB0 SIMATIC DP, INTERFACE

IM 153-1, FOR ET 200M,

FOR MAX. 8 S7-300 MODULES
  6ES7365-0BA01-0AA0 IM 365 Rack expansion module,be deployed with a central controller and a expansion rack

 

More pictures for your reference:

3211bl00 321-1BL00 332-5HD01-0AB0 331-7KF02-0AB0 S7-300 322-1BH02 S7-200 321-1BL00 331-1KF01 product 3311kf01 3311kf01-00

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com
Jul 1 2013

Mitsubishi FX1N-232-BD RS232 interface Board

Introduction to Mitsubishi FX1N-232-BD

The RS-232C communication board FX1N-232-BD (hereafter referred to as "232BD") is connected to the FX1S/FX1N Series PLC basic unit, and available for the applications described below.


1.1 Features of Mitsubishi FX1N-232-BD
1) Port to transfer the data using the non-procedure method between diversified RS-232C equipment.such as personal computer, bar code reader and printer
2) Port to transfer the data using a dedicated protocol between an RS-232C equipment
3) Port to connect a programming tool


1.2 Outside dimensions and name of each part to Mitsubishi FX1N-232-BD
 

30

The communication connector of the 232BD is the D-sub, 9-pin socket type. The table below shows the pin arrangement.

24

Pin No. Signal Meaning Function
1 CD Receive carrier detection Turns ON when carrier for data receive is detected.
2 RD Receive data input Receive data (RS-232C equipment to 232BD)
3 SD Send data input Send data (232BD to RS232C equipment)
4 ER Send request Turns ON when RS-232C equipment becomes ready for receive.
5 SG Signal ground Signal ground
6 DR Send enable Turns ON when send request is given to RS-232C equipment

 

1.3 System configuration of Mitsubishi FX1N-232-BD

For the system configuration, refer to the FX Series Communication User’s Manual offered separately.

 

Installation of Mitsubishi FX1N-232-BD

31

 

2.1 Installation procedure of Mitsubishi FX1N-232-BD
Make sure to turn off the power before installing the 232BD.
A) Communication board 232BD (function expansion board)
B) Connector for optional equipment
C)M3 screw to fix board (2 pieces) (offered as accessories of board)
D) Top cover for board (offered as an accessory of board)
E) M3 screw to fix top cover (offered as an accessory of board)
Note: This screw cannot be removed.
• Plug the communication board A) in to the connector B).
• Fix the board to the basic unit with two M3 screws C). (Tightening torque: 0.3 to 0.6 Nxm)
• Remove the top cover of the basic unit, and attach the top cover for board D) instead.
During attachment, remove D)’ with a nipper, etc. so that the connector of the board is exposed.
• Fix the top cover with an M3 screw E). (Tightening torque: 0.3 to 0.6 Nxm)
• When the FX1N-5DM is used also, refer to the handy manual offered with the FX1S/FX1N Series PLC main unit.
• Only one function expansion board is available for one FX1S/FX1N Series PLC basic unit. Never stack up two or more function expansion boards. (Even if they are stacked up, they do not function at all.) 

 

Specifications of Mitsubishi FX1N-232-BD

3.1 Environmental specifications of Mitsubishi FX1N-232-BD
The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of the PLC main unit.)

 

3.2 Power supply specifications of Mitsubishi FX1N-232-BD
5V DC, 20 mA is supplied as the power from the PLC.


3.3 Performance specifications of Mitsubishi FX1N-232-BD

Transmission standard In conformance to RS-232C
Maximum transmission distance 15 m maximum
External equipment connection method D-sub, 9-pin type (pin socket: manufactured by JST Mfg.) with JES-9P-2A3A lock metal (inch screw thread type)
D-sub 9-pin Layout 1: CD 2: RD(RXD) 3: SD(TXD) 4: ER(DTR) 5: SG(GND)
6: DR(DSR) 7, 8, 9: NC (not used)
LED indicators  
Communication method Half duplex, bi-directional
Protocol Non-procedure, dedicated protocol 1 procedure, dedicated protocol 4 procedure, protocol for programming tool
Isolation No insulated

 

Our company (Kollewin Technology CO., Limited) have a new product,

named FX1N-232-BD.

It is 100% compatible with Mitsubishi original FX1N-232-BD.

 

Part#: FX1N-232-BD

The unit price is USD35.00/pc  buy buttom

 

USER'S MUNUAL PDF of Mitsubishi communication board FX1N-232-BD:

FX1N-232-BD-USER'S MANUAL

 

FX1N-232-BD -1 FX1N-232-BD

 

Specification of Mitsubishi communication board FX1N-232-BD:

Product Name Communication Board
Fit for Mitsubishi FX1N PLC
Model NO. FX1N-232-BD
Connector Type RS232C DB9 Male Plug
Voltage DC 5V
Current 20mA
Max.Transmission Distance 15M
D-sub 9-pin Layout 1:CD;2:RD(RXD);3:SD(TXD);4:ER(DTR);5:SG(GND);6:DR(DSR);7,8,9:NC(not used)
Material Plastic, Metal

 

Description of Mitsubishi communication board FX1N-232-BD:

  • Port to transfer the data using the non-procedure method between diversified RS-232C equipment such as personal computer, bar code reader and printer.
  • Port to transfer the data using a dedicated protocol between an RS-232C equipment.
  • Port to connect a programming tool.
  • RS232C interface boards for Mitsubishi FX1N, anti-static and anti-surge.
  • This is OEM product, not Mitsubishi original part.

 

More communication boards, please click below links:

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

More pictures of communication board

FX1N-USB-BD-1 FX2N-485-BD+ FX3U-232-BD FX3U-422-BD FX3U-485-BD FX3U-CNV-BD FX3U-USB-BD FX2N-422-BD FX2N-USB-BD-1 FX1N-422-BD FX1N-485-BD FX2N-232-BD FX2N-485-BD

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com